Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial

Thiele, Holger, Kurz, Thomas, Feistritzer, Hans-Josef, Stachel, Georg, Hartung, Philipp, Eitel, Ingo, Marquetand, Christoph, Nef, Holger, Doerr, Oliver, Lauten, Alexander, Landmesser, Ulf, Abdel-Wahab, Mohamed, Sandri, Marcus, Holzhey, David, Borger, Michael, Ince, Hüseyin, Öner, Alper, Meyer-Saraei, Roza, Wienbergen, Harm, Fach, Andreas, Frey, Norbert, König, Inke R, Vonthein, Reinhard, Rückert, Yvonne, Funkat, Anne-Kathrin, de Waha-Thiele, Suzanne, Desch, Steffen · 2020 · European Heart Journal

Abstract

Aims: Transcatheter aortic valve implantation (TAVI) has emerged as established treatment option in patients with symptomatic aortic stenosis. Technical developments in valve design have addressed previous limitations such as suboptimal deployment, conduction disturbances, and paravalvular leakage. However, there are only limited data available for the comparison of newer generation self-expandable valve (SEV) and balloon-expandable valve (BEV). Methods and results: SOLVE-TAVI is a multicentre, open-label, 2 × 2 factorial, randomized trial of 447 patients with aortic stenosis undergoing transfemoral TAVI comparing SEV (Evolut R, Medtronic Inc., Minneapolis, MN, USA) with BEV (Sapien 3, Edwards Lifesciences, Irvine, CA, USA). The primary efficacy composite endpoint of all-cause mortality, stroke, moderate/severe prosthetic valve regurgitation, and permanent pacemaker implantation at 30 days was powered for equivalence (equivalence margin 10% with significance level 0.05). The primary composite endpoint occurred in 28.4% of SEV patients and 26.1% of BEV patients meeting the prespecified criteria of equivalence [rate difference −2.39 (90% confidence interval, CI −9.45 to 4.66); P equivalence = 0.04]. Event rates for the individual components were as follows: all-cause mortality 3.2% vs. 2.3% [rate difference −0.93 (90% CI −4.78 to 2.92); P equivalence < 0.001], stroke 0.5% vs. 4.7% [rate difference 4.20 (90% CI 0.12 to 8.27); P equivalence = 0.003], moderate/severe paravalvular leak 3.4% vs. 1.5% [rate difference −1.89 (90% CI −5.86 to 2.08); P equivalence = 0.0001], and permanent pacemaker implantation 23.0% vs. 19.2% [rate difference −3.85 (90% CI −10.41 to 2.72) in SEV vs. BEV patients; P equivalence = 0.06]. Conclusion: In patients with aortic stenosis undergoing transfemoral TAVI, newer generation SEV and BEV are equivalent for the primary valve-related efficacy endpoint. These findings support the safe application of these newer generation percutaneous valves in the majority of patients with some specific preferences based on individual valve anatomy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehaa036

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 262

Metadata

Authors
Thiele, H., Kurz, T., Feistritzer, H.-J., Stachel, G., Hartung, P., Eitel, I., Marquetand, C., Nef, H., Doerr, O., Lauten, A., Landmesser, U., Abdel-Wahab, M., Sandri, M., Holzhey, D., Borger, M., Ince, H., Öner, A., Meyer-Saraei, R., Wienbergen, H., Fach, A., Frey, N., König, I. R., Vonthein, R., Rückert, Y., Funkat, A.-K., de Waha-Thiele, S., & Desch, S.
Venue
European Heart Journal
Published
2020-02-12
Volume
41
Issue
20
Pages
1890-1899
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W3007190083
Cited by
262
References
28
FWCI
22.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial. https://app.cochat.ai/papers/10.1093/eurheartj/ehaa036
The paper
Thiele, H., Kurz, T., Feistritzer, H.-J., Stachel, G., Hartung, P., Eitel, I., Marquetand, C., Nef, H., Doerr, O., Lauten, A., Landmesser, U., Abdel-Wahab, M., Sandri, M., Holzhey, D., Borger, M., Ince, H., Öner, A., Meyer-Saraei, R., Wienbergen, H., . . . Desch, S. (2020). Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial. European Heart Journal. https://doi.org/10.1093/eurheartj/ehaa036

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.