Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Aims: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. Methods and results: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2–12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02–1.13)], age [HR 1.21 (95% CI 1.01–1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11–1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis–patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31–14.39)], device malposition [SHR 3.75 (95% CI 1.36–10.35)], EBEV [SHR 3.34 (95% CI 1.26–8.85)], and age [SHR 0.59 (95% CI 0.44–0.78)]. Conclusions: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Proportional Hazards Model for the Subdistribution of a Competing Risk
Fine, J. P., & Gray, R. J. (1999) · Journal of the American Statistical Association · doi:10.1080/01621459.1999.10474144 · Cited by 14,290
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationSimplified calculation of body surface area
(1987) · New England Journal of Medicine · doi:10.1056/nejm198710223171717 · Cited by 3,238 · cited 1×
“Body surface area (BSA) was calculated according to the Mosteller formula.(14) Pre-existing severe prosthesis–patient mismatch (PPM) of the bioprosthetic valve was also defined according to VARC II criteria, namely: indexed effective orifice area (EOA) <_0.”
Kappetein, A. P., Head, S. J., Genereux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs533 · Cited by 1,601 · cited 1×
“Major clinical endpoints were assessed according to the Valve Academic Research Consortium II (VARC II) criteria.(13) Body surface area (BSA) was calculated according to the Mosteller formula.”
Self-citationBaumgartner, H., Hung, J., Bermejo, J., Chambers, J. B., Edvardsen, T., Goldstein, S., Lancellotti, P., LeFevre, M., Miller, F., & Otto, C. M. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.02.009 · Cited by 1,349 · cited 2×
“The mechanism for bioprosthetic valve failure was classified according to criteria from the American Society of Echocardiography.”
Brown, J. M., O'Brien, S. M., Wu, C., Sikora, J. A. H., Griffith, B. P., & Gammie, J. S. (2009) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.08.015 · Cited by 937 · cited 1×
“An increase in the use of bioprosthetic tissue valves has been observed in the last decades.(1,2) Although bioprostheses offer the advantage of avoiding lifetime anticoagulation, their durability is limited.”
Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
Self-citationFive-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement
Makkar, R. R., Thourani, V. H., Mack, M. J., Kodali, S. K., Kapadia, S., Webb, J. G., Yoon, S.-H., Trento, A., Svensson, L. G., Herrmann, H. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1910555 · Cited by 832
Self-citationLancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567 · cited 1×
“The predicted EOA of bioprosthetic valves was derived from the normal reference values for different models and sizes previously published.(15) True internal diameter (ID) for each bioprosthetic valve, when available, was derived from previous publications.”
Self-citationCapodanno, D., Petronio, A. S., Prendergast, B., Eltchaninoff, H., Vahanian, A., Modine, T., Lancellotti, P., Sondergaard, L., Ludman, P. F., Tamburino, C., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx303 · Cited by 535
Self-citationDvir, D., Bourguignon, T., Otto, C. M., Hahn, R. T., Rosenhek, R., Webb, J. G., Treede, H., Sarano, M. E., Feldman, T., Wijeysundera, H. C., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030729 · Cited by 479 · cited 1×
“Structural valve degeneration was defined according to current standardized definitions.(18,19)”
Self-citationRibeiro, H. B., Rodés-Cabau, J., Blanke, P., Leipsic, J., Kwan Park, J., Bapat, V., Makkar, R., Simonato, M., Barbanti, M., Schofer, J., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx455 · Cited by 430
Self-citationTranscatheter Aortic Valve Implantation Within Degenerated Aortic Surgical Bioprostheses
Webb, J. G., Mack, M. J., White, J. M., Dvir, D., Blanke, P., Herrmann, H. C., Leipsic, J., Kodali, S. K., Makkar, R., Miller, D. C., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.057 · Cited by 327
Self-citationDurko, A. P., Osnabrugge, R. L., Van Mieghem, N. M., Milojevic, M., Mylotte, D., Nkomo, V. T., & Pieter Kappetein, A. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy107 · Cited by 304 · cited 1×
“Aortic ViV represents a significant proportion of TAVR procedures(21) and, given the increase in the use of bioprosthetic tissue valves,(2) the procedure is expected to continue to grow in numbers.(22) This is the first comprehensive long-term evaluation of aortic ViV.”
Isaacs, A. J., Shuhaiber, J., Salemi, A., Isom, O. W., & Sedrakyan, A. (2015) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2015.01.052 · Cited by 290 · cited 1×
“An increase in the use of bioprosthetic tissue valves has been observed in the last decades.(1,2) Although bioprostheses offer the advantage of avoiding lifetime anticoagulation, their durability is limited.”
Capodanno, D., Petronio, A. S., Prendergast, B., Eltchaninoff, H., Vahanian, A. S., Modine, T., Lancellotti, P., Søndergaard, L., Ludman, P., Tamburino, C., et al. (2017) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx244 · Cited by 231
Self-citationLate results of heart valve replacement with the Hancock II bioprosthesis
David, T. E., Ivanov, J., Armstrong, S., Feindel, C. M., & Cohen, G. (2001) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.112208 · Cited by 190 · cited 1×
“Although bioprostheses offer the advantage of avoiding lifetime anticoagulation, their durability is limited.(3) A rapidly growing number of bioprostheses will thus require reintervention over time for the treatment of structural valve degeneration (SVD).”
Effect of Valve Design on the Stent Internal Diameter of a Bioprosthetic Valve
Bapat, V. N., Attia, R., & Thomas, M. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.10.012 · Cited by 176 · cited 1×
“True internal diameter (ID) for each bioprosthetic valve, when available, was derived from previous publications.(16) Malposition was operator-reported and defined as inadequate final position of the transcatheter heart valve (THV) for any cause.”
Webb, J. G., Murdoch, D. J., Alu, M. C., Cheung, A., Crowley, A., Dvir, D., Herrmann, H. C., Kodali, S. K., Leipsic, J., Miller, D. C., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.03.483 · Cited by 166 · cited 2×
“Survival after aortic ViV was recently reported in a smaller cohort of high-risk patients from the PARTNER trial.(23) Patients had a mean age of 78.”
Self-citationSimonato, M., Webb, J. G., Kornowski, R., Vahanian, A. S., Frerker, C., Nissen, H., Bleiziffer, S., Duncan, A., Rodés‐Cabau, J., Attizzani, G. F., et al. (2016) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.115.003651 · Cited by 141
Self-citationPîbarot, P., Simonato, M., Barbanti, M., Linke, A. H.-P., Kornowski, R., Rudolph, T. K., Spence, M., Moat, N. E., Aldea, G. S., Mennuni, M. G., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.08.039 · Cited by 136
Self-citationDeeb, G. M., Chetcuti, S. J., Reardon, M. J., Patel, H. J., Grossman, P. M., SCHREIBER, T. L., Forrest, J. K., BAJWA, T. K., O’Hair, D. P., Petrossian, G., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.03.018 · Cited by 123
Deutsch, M.-A., Erlebach, M., Burri, M., Hapfelmeier, A., Witt, O. G., Ziegelmueller, J. A., Wottke, M., Ruge, H., Krane, M., Piazza, N., et al. (2018) · EuroIntervention · doi:10.4244/eij-d-17-00603 · Cited by 108
Self-citationHemodynamic Deterioration of Surgically Implanted Bioprosthetic Aortic Valves
Salaun, E., Mahjoub, H., Dahou, A., Mathieu, P., Larose, É., Després, J.-P., Rodés-Cabau, J., Arsenault, B. J., Puri, R., Clavel, M.-A., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.04.064 · Cited by 93 · cited 1×
“27 30 Taken together with prior findings, our study adds further evidence and insight into the fact that small bioprostheses, which frequently exhibit severe PPM, bear a high risk for worse outcomes after ViV procedures.”
Self-citationDeterminants of aortic bioprosthetic valve calcification assessed by multidetector CT
Mahjoub, H., Mathieu, P., Larose, É., Dahou, A., Sénéchal, M., Dumesnil, J., Després, J., & Pîbarot, P. (2015) · Heart · doi:10.1136/heartjnl-2014-306445 · Cited by 90
Clinical Valve Thrombosis After Transcatheter Aortic Valve-in-Valve Implantation
Abdel‐Wahab, M., Simonato, M., Latib, A., Goleski, P. J., Allali, A., Kaur, J., Azadani, A. N., Horlick, E. M., Testa, L., Orvin, K., et al. (2018) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.118.006730 · Cited by 86 · cited 1×
“In prior analyses, thrombosis is resolved with anticoagulation in the majority of cases without a need for reintervention.(11) In the current data, we have identified two cases requiring reintervention due to valve thrombosis.”
Self-citationIncidence, predictors and clinical outcomes of residual stenosis after aortic valve-in-valve
Bleiziffer, S., Erlebach, M., Simonato, M., Pîbarot, P., Webb, J. G., Capek, L., Windecker, S., George, I., Sinning, J., Horlick, E. M., et al. (2018) · Heart · doi:10.1136/heartjnl-2017-312422 · Cited by 81
Self-citationSimonato, M., Azadani, A. N., Webb, J. G., Leipsic, J. A., Kornowski, R., Vahanian, A. S., Wood, D. A., Piazza, N., Kodali, S., Ye, J., et al. (2016) · EuroIntervention · doi:10.4244/eijv12i7a149 · Cited by 70
Self-citationFlameng, W. J., Meuris, B., Herijgers, P., & Herregods, M. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2006.03.089 · Cited by 62
Long-Term Outcomes After Transcatheter Aortic Valve-in-Valve Replacement
Guimaraes, L. D. F. C., Ureña, M., Wijeysundera, H. C., Muñoz-García, A. J., Serra, V., Benitez, L. M., Auffret, V., Cheema, A. N., Amat-Santos, I. J., Fischer, Q., et al. (2018) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.118.007038 · Cited by 51 · cited 1×
“9%.(25) The current data from the VIVID Registry include a much larger number of high-risk patients (n = 1006) with longer follow-up and reveal an 8-year survival rate of 38.”
Self-citationDauerman, H. L., Deeb, G. M., O’Hair, D. P., Waksman, R., Yakubov, S. J., Kleiman, N. S., Chetcuti, S. J., Hermiller, J. B., BAJWA, T. K., Khabbaz, K. R., et al. (2019) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.119.008155 · Cited by 45 · cited 1×
“02).(24) As THVs may be under-expanded when implanted in small bioprosthetic valves, which may be further modified by the depth of implantation,(26) the final result may be postulated to be even worse.”
Simonato, M., Webb, J. G., Bleiziffer, S., Abdel‐Wahab, M., Wood, D. A., Seiffert, M., Schäfer, U., Wöhrle, J., Jochheim, D., Woitek, F. J., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.05.057 · Cited by 23
Self-citationDvir, D., Webb, J. G., Blanke, P., Park, J., Mack, M. J., Pîbarot, P., Dewey, T. M., Herrmann, H. C., Kapadia, S. R., Kodali, S., et al. (2017) · Structural Heart · doi:10.1080/24748706.2017.1329571 · Cited by 3 · cited 1×
“Small bioprosthetic valves were defined as true ID <_20 mm and, conversely, large bioprosthetic valves were defined as true ID >20 mm.(17) Structural valve degeneration was defined according to current standardized definitions.”
Self-citation
Cited by
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Self-citation2021 ESC/EACTS Guidelines for the management of valvular heart disease
Beyersdorf, F., Vahanian, A., Milojevic, M., Praz, F., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2021) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezab389 · Cited by 622
Self-citation2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · EuroIntervention · doi:10.4244/eij-e-21-00009 · Cited by 372
Metadata
- Authors
- Bleiziffer, S., Simonato, M., Webb, J. G., Rodés-Cabau, J., Pibarot, P., Kornowski, R., Windecker, S., Erlebach, M., Duncan, A., Seiffert, M., Unbehaun, A., Frerker, C., Conzelmann, L., Wijeysundera, H., Kim, W.-K., Montorfano, M., Latib, A., Tchetche, D., Allali, A., Abdel-Wahab, M., Orvin, K., Stortecky, S., Nissen, H., Holzamer, A., Urena, M., Testa, L., Agrifoglio, M., Whisenant, B., Sathananthan, J., Napodano, M., Landi, A., Fiorina, C., Zittermann, A., Veulemans, V., Sinning, J.-M., Saia, F., Brecker, S., Presbitero, P., De Backer, O., Søndergaard, L., Bruschi, G., Franco, L. N., Petronio, A. S., Barbanti, M., Cerillo, A., Spargias, K., Schofer, J., Cohen, M., Muñoz-Garcia, A., Finkelstein, A., Adam, M., Serra, V., Teles, R. C., Champagnac, D., Iadanza, A., Chodor, P., Eggebrecht, H., Welsh, R., Caixeta, A., Salizzoni, S., Dager, A., Auffret, V., Cheema, A., Ubben, T., Ancona, M., Rudolph, T., Gummert, J., Tseng, E., Noble, S., Bunc, M., Roberts, D., Kass, M., Gupta, A., Leon, M. B., & Dvir, D.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-06-27
- Volume
- 41
- Issue
- 29
- Pages
- 2731-2742
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W3037437112
- Cited by
- 169
- References
- 33
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.