The clinical impact of implantable loop recorders in patients with syncope
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
AIMS: Implantable loop recorders (ILR) provide an opportunity to record ECG data from a spontaneous syncopal event. We conducted a randomized study to investigate the impact of the Reveal Plus ILR on an unselected population of patients with recurrent syncope. Initial follow-up (at least 6 months) did not demonstrate a reduction in syncopal events or an improvement in quality of life. We report the planned extension of follow-up to 18 months. METHODS AND RESULTS: All patients presenting acutely with recurrent unexplained syncope over a 16-month period, following a basic clinical work-up, were randomized to receive the ILR or conventional investigation and management. A total of 421 patients presented, 201 were eligible, median age 74, (IQ range 61-81) 54% female, with median syncopes 3 (IQ range 2-6). Median follow-up 17 months (IQ range 9-23). 42 (43%) of ILR patients and 8 (6%) of conventional patients received an ECG diagnosis (hazard ratio 6.53, 95% CI 3.73-11.4, P<0.001). Time to second syncope was significantly longer for ILR patients, although of borderline significance (P=0.04). A greater variety of diagnoses and treatments were seen in ILR patients. ILR patients had fewer post-randomization investigations and fewer days in hospital; however, cost savings were not statistically significant. There was improved quality of life in the ILR group (visual analogue scales, P=0.03) for general wellbeing. Overall mortality was 12% with no difference between the two groups. CONCLUSION: Investigation by the ILR significantly increases the diagnostic rate and ECG directed treatments in a typical unselected syncopal population. Long-term follow-up has demonstrated a significant subsequent reduction in syncopal events with improved quality of life.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is important to note that there have been randomized controlled trials of the devices’ clinical effectiveness, and the results consistently show that for older patients with unexplained syncope, recorders should be used earlier in the investigation rather than later.102–104”
In the citing paper
“Next to noninvasive monitoring strategies, implantable loop recorders (ILR) are used to confirm the etiology of syncope [2,12,13,14,15,16,17,18]”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [2]
In the citing paper
“Diagnostic rates above 50% with the use of an ILR have been reported in other, smaller studies19–21 with one early study claiming >90%.22”
From Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry (2011) · cites this paper as [22]
In the citing paper
“its clinical usefulness to confirm the diagnosis in patients with syncope of unknown cause has been well established [2], [3], [4], [5], [6].”
From Ambulatory electrocardiogram monitoring devices for evaluating transient loss of consciousness or other related symptoms (2017) · cites this paper as [4]
In the citing paper
“ILR was more cost-effective than a conventional strategy. 172,173,177,178”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [172]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
An analysis of variance test for normality (complete samples)
SHAPIRO, S. S., & WILK, M. B. (1965) · Biometrika · doi:10.1093/biomet/52.3-4.591 · Cited by 23,480
Efron, B., & Tibshirani, R. (1986) · Statistical Science · doi:10.1214/ss/1177013815 · Cited by 6,033
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Modelling Survival Data in Medical Research
Collett, D. (1994) · Springer eBooks · doi:10.1007/978-1-4899-3115-3 · Cited by 1,065
Committee Members, Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 910
Evaluation and outcome of emergency room patients with transient loss of consciousness
Day, S. C., Cook, E. F., Funkenstein, H., & Goldman, L. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90913-5 · Cited by 587
Evaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Mechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators (2001) · Circulation · doi:10.1161/hc3601.095708 · Cited by 378
Epidemiologic features of isolated syncope: the Framingham Study.
Savage, D. D., Corwin, L., McGee, D. L., Kannel, W. B., & Wolf, P. A. (1985) · Stroke · doi:10.1161/01.str.16.4.626 · Cited by 366
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Research works printed but not linked: 2
- Williams RL, Allen PD. Loss of consciousness. Aerosp Med1962;33:545–551. Ref type: Generic.
- Syncope; simple or serious? Minn Med1967;50:1543–1547.
Cited by
Items 101–200 of 231
Self-Terminated Ventricular Fibrillation and Recurrent Syncope
Konstantino, Y., Morello, A., ZIMETBAUM, P. J., & Josephson, M. E. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.10.025 · Cited by 8
Loop recorders for syncope evaluation: what is the evidence?
Cheung, C. C., & Krahn, A. D. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1243463 · Cited by 8
“In an older population (median age 74 years) with recurrent syncope (median 3 syncopal events) and a median 17 months follow-up, 43% of ILR patients received an ECG diagnosis compared to 6% of conventional treatment patients [24].”
BackgroundResultInfluentialSolbiati, M., Casazza, G., Dipaola, F., Sheldon, R. S., & Costantino, G. (2016) · Heart · doi:10.1136/heartjnl-2016-309980 · Cited by 8
Altinsoy, M., Sutton, R., Kohno, R., Sakaguchi, S., Mears, R. K., & Benditt, D. G. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12560 · Cited by 7
Economic value of insertable cardiac monitors in unexplained syncope in the United States
Sutton, B. S., Bermingham, S. L., Diamantopoulos, A., Rosemas, S. C., Tsintzos, S. I., Xia, Y., & Reynolds, M. R. (2021) · Open Heart · doi:10.1136/openhrt-2020-001263 · Cited by 7
CURRENT METHODS OF AMBULATORY ELECTROCARDIOGRAM MONITORING. TECHNICAL ASPECTS
Pervova, E. V. (2017) · The Clinician · doi:10.17650/1818-8338-2016-10-4-16-28 · Cited by 7
Implantable Loop Recorders for Cardiac Dysrhythmia Monitoring
Akella, K., Murtaza, G., Rocca, D. G. D., Kodwani, N., Gopinathannair, R., Natale, A., & Lakkireddy, D. (2020) · Future Cardiology · doi:10.2217/fca-2020-0035 · Cited by 7
Use of Implantable Loop Recorders to Unravel the Cause of Unexplained Syncope
Puri, A., & Srivastava, R. K. (2013) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30606-4 · Cited by 7
“In the East Bourne Syncope Assessment Study [22], performed in a typical unselected population, there was an increased diagnostic rate in the group of patients randomized to ILR management and ECGdirected treatments than in conventional investigation group.”
Clinical Utility of Implantable Loop Recorders
Houmsse, M., Ishola, A., & Daoud, E. G. (2014) · Postgraduate Medicine · doi:10.3810/pgm.2014.03.2738 · Cited by 7
Rocha, B., Gomes, R., Cunha, G., Silva, B. M. V., Pocinho, R., Morais, R., Araújo, I., & Fonseca, C. (2019) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2019.11.013 · Cited by 6
Reed, M. J., Grubb, N. R., Lang, C., Goodacre, S. W., O’Brien, R., Weir, C. J., Thokala, P., Freeman, N., Blackstock, C., Dinsmore, L., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-069530 · Cited by 6
Syncope in Patients with Organic Heart Disease
Olshansky, B., & Sullivan, R. M. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.013 · Cited by 6
Unexplained Syncope: The Importance of the Electrophysiology Study
Doundoulakis, I., Σουλαϊδόπουλος, Σ., Αρσένος, Π., Dilaveris, P., Tsiachris, D., Antoniou, C. K., Sideris, S. K., Kordalis, A., Laina, A., Kallinikidis, S., et al. (2021) · Hearts · doi:10.3390/hearts2040038 · Cited by 6
Implantable cardiac devices in geriatric patients: a primer for primary and geriatric physicians
Wani, F., Amir, R., Aljadah, M. M., Albosta, M. S., Guidi, J. C., Singh, J., Kanjwal, K., & Kichloo, A. (2021) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm.2021.01.222 · Cited by 5
“that at 18 months post implantation patients had improved general well-being, measured using questionnaires [16].”
BackgroundMethodInfluentialDuvillier, L., Demolder, A., Renterghem, S. V., Mey, C. D., West, F., & Pooter, J. D. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16420 · Cited by 5
“9 12 ILRs allow long ‐ term surveillance of a single ‐ lead electrocardiogram (ECG) and have been shown to be effective tools in detecting clinically relevant arrhythmias, 13 – 17 thereby leading to an earlier diagnosis.”
Turley, A. J., Tynan, M., & Plummer, C. (2009) · EP Europace · doi:10.1093/europace/eup193 · Cited by 5
The implantable loop recorder in children: searching for indications
Pass, R. H., & Liberman, L. (2008) · Heart · doi:10.1136/hrt.2007.126276 · Cited by 5
“higher diagnostic rates with no devicerelated adverse events.(4)”
BackgroundAdkisson, W. O., & Benditt, D. G. (2012) · EP Europace · doi:10.1093/europace/eus224 · Cited by 5
Mueller-Leisse, J., Hillmann, H. A. K., Iserloh, L., Fruehauf, B., & Duncker, D. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13061564 · Cited by 4
Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R. K., & Krahn, A. D. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_23 · Cited by 4
Salih, H., Monsel, F., Sergent, J., & Amara, W. (2012) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2012.08.033 · Cited by 4
El síncope: un problema con mayúsculas
Moya‐Mitjans, À., Rivas‐Gándara, N., Pérez‐Rodon, J., Roca, I., & García‐Dorado, D. (2010) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(10)70112-6 · Cited by 5
Vasovagal syncope and unexplained syncope: Concepts, treatments, and future perspectives.
Bédard, F., Marchand, A., Kuś, T., & D’Antono, B. (2010) · Canadian Psychology/Psychologie canadienne · doi:10.1037/a0021273 · Cited by 4
Experience With Implantable Loop Recorders for Recurrent Unexplained Syncope
Brignole, M. (2008) · Congestive Heart Failure · doi:10.1111/j.1751-7133.2008.tb00014.x · Cited by 4
Matthews, I. G., Tresham, I. A. E., & Parry, S. W. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.016 · Cited by 4
Przyżycka, P., Kałowski, M., Poddębska, I., Kaczmarek, K. A., Ptaszynski, P. A., Wranicz, J. K., & Cygankiewicz, I. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.04.006 · Cited by 4
Neurological Complications of Systemic Disease
Aminoff, M. J., & Josephson, S. A. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0434-1.00056-6 · Cited by 4
Choi, Y. Y., Choi, J., Kim, Y. G., Min, K., Roh, S., Shim, J., Choi, J. S., & Kim, Y. (2022) · International Journal of Arrhythmia · doi:10.1186/s42444-022-00068-w · Cited by 4
“[12] reported that treatment based on ILR diagnosis significantly reduced syncope recurrence when compared to treatment based on conventional diagnostic methods.”
MethodNumeroso, F., Mossini, G., Lippi, G., & Cervellin, G. (2017) · Acta cardiologica. Supplementum · doi:10.1080/00015385.2017.1362146 · Cited by 5
Autonomes Nervensystem und Reflexsynkope
BOSCH, R. F. (2021) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-021-00775-2 · Cited by 4
Táborský, M., Kautzner, J., Fedorco, M., Čurila, K., Wünschová, H., Pyszko, J., Novák, M., Kozák, M., Válek, M., Polášek, R., et al. (2022) · Cor et Vasa · doi:10.33678/cor.2022.024 · Cited by 4
Neurological Complications of Systemic Disease
Aminoff, M. J. (2008) · Elsevier eBooks · doi:10.1016/b978-0-7506-7525-3.50063-7 · Cited by 4
Characterisation of wearable and implantable physiological measurement devices
Riistama, J. M. (2010) · Tampere University Institutional Repository (Tampere University) · Cited by 4
Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Nazzari, H., Halperin, L. F., & Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99770-9 · Cited by 4
Bradycardia risk stratification with implantable loop recorder after unexplained syncope
Ciancio, G. D., Sadoul, N., Hammache, N., Pace, N., Echivard, M., Freysz, L., Blangy, H., Sellal, J., & Olivier, A. (2024) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2023.12.007 · Cited by 3
Kim, J., Oh, I.-Y., Cha, M., Ahn, J., Lee, S., Lee, S. H., Uhm, J., Yang, P., Shim, J., Park, H., et al. (2025) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2024.364 · Cited by 4
Chien, D. V., Bình, N. T., Dung, N., & Son, P. T. (2021) · Cardiology Research and Practice · doi:10.1155/2021/8496351 · Cited by 3
“Continuous ECG monitoring for more than 24 h is preferred to detect more silent heart rhythm disorders [2], and external ECG recorders have been shown to be noninvasive and more feasible with high efficacy.”
BackgroundKarlinski, M. A., Grabowski, M., Kempa, M., Farkowski, M. M., Sławek, J. W., Rejdak, K., Mitkowski, P. P., Hryniewiecki, T., & Słowik, A. (2024) · Kardiologia Polska · doi:10.33963/v.phj.99401 · Cited by 3
Syncope in Patients with Organic Heart Disease
Olshansky, B., & Sullivan, R. M. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.006 · Cited by 3
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 3
Implantable loop recorder is an effective diagnostic tool for unexplained syncope.
Bovin, A., Malczynski, J., & Dalsgaard, D. (2012) · PubMed · Cited by 3
Malaise, lipothymie et syncope
Cambournac-Buan, A., Dadone, B. C., & Trinh-Duc, A. (2014) · Time to knit · doi:10.1016/s1241-8234(22)47282-8 · Cited by 3
Ray, J. C., Kusumoto, F. M., & Goldschlager, N. (2014) · Journal of Intensive Care Medicine · doi:10.1177/0885066614552988 · Cited by 3
Indikationen Zur Loop-Rekorder-Implantation Bei Synkope
Schuchert, A. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0571-1 · Cited by 2
Tang, Y., Zuo, B., Chen, B., Fan, C., Zhou, J., Song, Y., & Fu, J. X. (2025) · Journal of Arrhythmia · doi:10.1002/joa3.70193 · Cited by 2
“As the primary source of these two parameters was from the only randomized controlled trial [17] with limited sample size, we used alternative sources to further assess the robustness of the model results.”
Vidya, P. L., Ananthakrishnan, R., Mukherjee, R., Sharma, P., Joshi, S., & Mohanty, S. (2021) · Medical Journal Armed Forces India · doi:10.1016/j.mjafi.2020.12.016 · Cited by 2
Amara, W., Sileu, N., Salih, H., Sergent, J., & Monsel, F. (2014) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2014.08.007 · Cited by 2
Prognostic opportunities and limitations in implantable medical devices
Hareland, S. A., & Radtke, L. P. (2013) · IEEE Conference on Prognostics and Health Management · doi:10.1109/icphm.2013.6621412 · Cited by 2
“Implantable medical devices are widely utilized to treat a variety of medical and health conditions ranging from the timely termination of dangerous, immediately life-threatening cardiac arrhytlunias [1-2] to patient monitoring and reporting of diagnostic information for patient management [3].”
BackgroundCode Clone Detection Using String Based Tree Matching Technique
Selamat, A., & Wahi, N. (2010) · InTech eBooks · doi:10.5772/7303 · Cited by 2
Clinical evaluation and risk stratification in patients with syncope
Koenig, T. W., Duncker, D., Hohmann, S., Schroeder, C., Oswald, H., & Veltmann, C. (2014) · Herz · doi:10.1007/s00059-014-4099-9 · Cited by 2
Evaluación económica del Holter implantable para el diagnóstico de síncope en España
Baena, I. G., García, F. J., Abad, R. N., Sánchez, B. M., & Barrios, J. M. R. (2011) · PharmacoEconomics Spanish Research Articles · doi:10.1007/bf03320886 · Cited by 2
Adkisson, W. O., Can, I., & Benditt, D. G. (2020) · Contemporary cardiology · doi:10.1007/978-3-030-41967-7_23 · Cited by 2
Matsumoto, K., Kodama, Y., Ito, S., Nakamura, Y., Fujiwara, R., Kajio, K., Kasamatsu, K., Murata, E., Nakamura, Y., & Kawase, Y. (2022) · Heart and Vessels · doi:10.1007/s00380-022-02212-x · Cited by 2
“Although several studies have suggested that ICM is more cost effective than a conventional testing approach [8, 11, 39], ICM incurs a greater upfront cost [11, 15] and a risk of procedure-related complications [16].”
BackgroundMethodSynkopendiagnostik: wann ambulant, wann stationär?
Schuchert, A., & Wille, E. (2008) · Herz · doi:10.1007/s00059-008-3145-x · Cited by 2
“Diese Befunde weisen darauf hin, dass die frühzeitige Implantation eines Ereignisrekorders bei Patienten mit rezidivierenden Synkopen unklarer Genese nicht nur einen diagnostischen, sondern auch einen therapeutischen Gewinn darstellt [15].”
BackgroundGehi, A. K., & Narla, V. A. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.10.008 · Cited by 2
Jeong, J. H., Lee, S., Oh, I., Cha, M., Lim, H. E., Park, H., Yang, P., Lee, S. H., Park, J., Kim, K., et al. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16509 · Cited by 1
“Improved quality of life in other ILR indications was not specified in our study, but a significant reduction of recurrent syncope with improved quality of life in patients has been suggested previously [20].”
Immediate Ambulatory Electrocardiographic Monitoring in Syncope
Reed, M. J., Goodacre, S. W., Weir, C. J., Dinsmore, L., Nugent, A., Kennel, T., Lang, C., Grubb, N. R., Thokala, P., Kilcoyne, K., et al. (2026) · New England Journal of Medicine · doi:10.1056/nejmoa2605812 · Cited by 1
The Effect of Late Adoption of Canadian Innovations: A Case for Implantable Cardiac Monitors
Sadri, H., & Winsor, P. (2014) · Healthcare Management Forum · doi:10.1016/j.hcmf.2014.01.002 · Cited by 1
“However, currently, the standard of diagnosis remains the recording of physical observations following a spontaneous syncope event.(17) Owing to the transitory and unpredictable nature of syncope, the opportunity of recording data seldom arises and tests such as tilt table, carotid sinus massage, and EP studies rely o…”
BackgroundManagement of syncope: from evidence to clinical practice
Attardo, T. M., Ambrosino, I., Magnani, E., Artom, N., Battino, N., Cervo, D., Chiuch, M., Frualdo, M., Gino, M., Pasin, F., et al. (2016) · Italian Journal of Medicine · doi:10.4081/itjm.2016.732 · Cited by 1
Implantable Loop Recorder in Clinical Practice
Babuty, D., Pierre, B., Clémenty, N., Lallemand, B., Marie, O., & Fauchier, L. (2011) · InTech eBooks · doi:10.5772/21350 · Cited by 1
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.009 · Cited by 1
Advances in syncope: With emphasis on reflex syncope
Fisher, J. D. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9579-8 · Cited by 1
“Arguments have been made that cost per diagnosis is actually cheaper with an ILR than with conventional stepwise approaches [4, 5].”
OBSOLETE: Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99770-8 · Cited by 1
Registadores de Eventos Implantados no Diagnóstico de Síncope
Oliveira, T. (2019) · Medicina Interna · doi:10.24950/rspmi/revisao/63/18/2/2019 · Cited by 1
Krahn, A. D., Yee, R., Skanes, A. C., & Klein, G. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-44733-1.00066-3 · Cited by 1
Differenzialdiagnostik unklarer Synkopen
Seewöster, T., Lindemann, F., & Hindricks, G. (2019) · Herz · doi:10.1007/s00059-019-04852-8 · Cited by 1
The Economic Impact of Syncope: Direct and Indirect Costs
Narichania, A. D., & Hamdan, M. H. (2020) · Springer eBooks · doi:10.1007/978-3-030-44507-2_4 · Cited by 1
Implantable cardiac monitors: State of the art
Jamal, S. M., Prasad, R. M., Vipparla, N. S., Srivastava, S., Baloch, Z. Q., Banga, E., & Ip, J. H. (2021) · Interventional Cardiology · Cited by 1
Willy, K., Ellermann, C., Syring, S., Rath, B., Reinke, F., Willy, D., Wolfes, J., Wegner, F. K., Eckardt, L., Köbe, J., et al. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12081219 · Cited by 1
Pascual, J. F., Medina-Maguiña, J. M., & Rivas‐Gándara, N. (2025) · Medicina Clínica (English Edition) · doi:10.1016/j.medcli.2025.107107 · Cited by 1
Xie, R., Hong, S., Gao, G., Zhong, J., Geng, L., Gao, S., Xu, Y., Meiling, D., Li, J., Li, Y., et al. (2021) · Research Square · doi:10.21203/rs.3.rs-1056296/v1 · Cited by 1
di Ruffano, L. F. (2013) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Registadores de eventos implantados no diagnóstico da síncope.
Oliveira, T. D. S. (2018) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/z31y-7j33 · Cited by 1
Clinical Trials Landscape: What's New, What's Ongoing, What Do We Need
Brignole, M., Benditt, D. G., & Wieling, W. (2007) · Wiley eBooks · doi:10.1002/9780470692639.ch27
Was ist neu in der ESC-Leitlinie von 2009?
von Scheidt, W., & Seidl, K. (2011) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-011-0133-2
Somlói, M., Toldy-Schedel, E., Nényei, Z., Böszörményi, R., & Tomcsányi, J. (2015) · Orvosi Hetilap · doi:10.1556/oh.2015.30124
Syncope with Heart Disease - Provoke and See or Wait and Watch ?
Selvaraj, R. J. (2015) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30839-7
“This approach has resulted in a high detection rate of the cause of syncope [5, 6] and it can be argued that it continues to be underutilized in the evaluation of these patients as it appears to be in this study.”
ResultClinical Usefulness of Implantable Loop Recorder
Park, S. (2015) · Arrhythmia · doi:10.18501/arrhythmia.2015.025
Cambournac-Buan, A., Dadone, B. C., & Trinh-Duc, A. (2015) · EMC - Urgenze · doi:10.1016/s1286-9341(15)70472-2
Sadri, H., & Winsor, P. (2014) · Healthcare Management Forum · doi:10.1016/j.hcmf.2014.03.005
Boldly Monitoring where Few People Have Monitored Before
McCurdy, R., & Kowey, P. R. (2008) · Cardiology · doi:10.1159/000127444
Long‐Term Insertable Loop Monitors: How Much Should We Watch to Get an Answer (Diagnosis)?
KIM, M. H. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02158.x
“It is important to note that the cost-effectiveness of implementing a strategy of very prolonged ILR monitoring is unknown and multiple factors could influence such an analysis including (1) appropriate or inappropriate ILR utilization based on clinical presentation, (2) cost of the device, implant, and follow-up, (3)…”
BackgroundImplantable Device to Monitor Cardiac Activity with Sternal Wires
Ganapathy, A. V., Palmer, A., BURRER, A., Bersi, M. R., GARZA, J., & Razavi, M. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12487
Beleslin, B., Deljanin, M., Kanjuh, V., Parapid, B. J., Giga, V. L., Prostran, M. S., Angelkov, L., Balinovac, J., Bikicki, M., Ambrosio, G., et al. (2013)
E L TRATAMIENTO DE LAS ARRITMIAS : PERSPECTIVA DE UN DESAFÍO
Moyá, A., Rivas‐Gándara, N., Pérez‐Rodon, J., Roca, I., & García‐Dorado, D. (2016)
An update on the use of implantable loop recorders
Gilmore, M., & Anderson, M. (2016) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2016.11.1.21
Management del paziente con cefalea, vertigine e sincope: dalle evidenze alla pratica clinica
Gnerre, P., Attardo, T. M., & Giovani, A. N. D. G. F. (2016) · Italian Journal of Medicine · doi:10.4081/itjm.q.2016.2
Implanterbar rytmeovervåker ved utredning av synkope
Christiansen, C. S. (2007) · NVA (Nasjonalt vitenarkiv)
Value of Ambulatory Electrocardiogra phic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013)
Implantierbare Loop-Rekorder in der Synkopendiagnostik
Kaess, B. M., & Ehrlich, J. R. (2016) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-016-0476-9
Brignole, M., Blanc, J., Sutton, R., & Moyá, A. (2009)
Implantable syncope and arrhythmia monitors, and automated external defibrillators
PHILLIPS, J. R., & Ro, P. S. (2017) · Wiley eBooks · doi:10.1002/9781119333050.ch17
Cardiovascular associations of falls and syncope in the elderly
Bhangu, J. S. (2017) · Trinity's Access to Research Output (TARA) (Trinity College Dublin)
Use of Implantable Monitors for Arrhythmia Detection
Tomala, J., & Piorkowski, C. (2019) · Springer eBooks · doi:10.1007/978-3-030-22882-8_9
张, 雁. (2019) · Advances in Clinical Medicine · doi:10.12677/acm.2019.911196
Krahn, A. D., Yee, R. K., Skanes, A. C., & Klein, G. J. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00064-9
Dong, Y., Yang, M., Zhang, R., Li, G., Li, D., Yin, X., Gao, L., & Xia, Y. (2019) · International Journal of Heart Rhythm · doi:10.4103/ijhr.ijhr_5_20
Differenzialdiagnostik unklarer Synkopen
Seewöster, T., Lindemann, F., & Hindricks, G. (2020) · CME · doi:10.1007/s11298-020-8062-1
Indicazioni all’utilizzo diagnostico del loop recorder impiantabile ed esterno
Brignole, M., Vardas, P. E., Hoffman, E., Huikuri, H. V., Moyá, A., Ricci, R. P., Sulke, N., & Wieling, W. (2011) · Giornale Italiano di Aritmologia e Cardiostimolazione
Self-citation
Metadata
- Authors
- Farwell, D. J., Freemantle, N., & Sulke, N.
- Affiliations
- Eastbourne District General Hospital (GB)
- Corresponding author
- Farwell, David J.
- ORCID
- Freemantle, Nick
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-11-28
- Volume
- 27
- Issue
- 3
- Pages
- 351-356
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2116206997
- Cited by
- 219
- References
- 35
- Citations by year
- 2026: 6 · 2025: 4 · 2024: 6 · 2023: 8 · 2022: 6 · 2021: 16 · 2020: 5 · 2019: 9 · 2018: 10 · 2017: 19 · 2016: 14 · 2015: 15 · 2014: 17 · 2013: 16 · 2012: 11
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- University of Birmingham Research Portal (University of Birmingham) (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- HighWire Press Open Archive (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Life Sciences › Neuroscience › Neurology › Vestibular and auditory disorders
- Keywords
- implantable loop recorder, recurrent syncope, unexplained syncope, syncope diagnosis, quality of life, syncope recurrence, mortality, cost reduction
- MeSH terms
- Aged, Aged, 80 and over, Cost-Benefit Analysis, Electrodes, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prognosis, Quality of Life, Recurrence, Syncope, Time Factors, Electrocardiography, Ambulatory, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.