The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Do implantable loop recorders impact the survival of patients with recurrent unexplained syncope?
Open accessAbstract
Aim: This study compares the outcomes of patients who receive an implantable loop recorder (ILR) for unexplained syncope to a control group without the diagnostic device in German claims data. Methods and materials: Patients with ILR were matched to a control group based on prior syncope events, age, gender and Charlson Comorbidity index (CCI). Survival, syncope hospitalizations, treatment and costs were compared. Results/conclusion: Four hundred and twelve ILR patients were matched with controls, mean age was 68, mean CCI was 2.7, 42% females. ILR patients lived on average 1.2 years longer than patients in the control group. Twenty-five percent of ILR patients received a therapeutic device compared with 5% in the control group. ILRs might help to diagnose and treat patients with positive impact on survival.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Hence, the ILR provided a high diagnostic yield in terms of cardiac arrhythmias in patients with syncope, not restricted to arrhythmias directly related to syncope [12,13,14,15,17,19,35,36] but including other diagnoses with therapeutic implications such as atrial fibrillation.”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [19]
In the citing paper
“with a shorter time to diagnosis, more frequent treatment initiation, and a positive impact on survival compared to a conventional diagnostic workup [13,17,19].”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [19]
Citations
Cites
Validation of a combined comorbidity index
Charlson, M., Szatrowski, T. P., Peterson, J., & Gold, J. (1994) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)90129-5 · Cited by 6,587
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Incidence and Prognosis of Syncope
Soteriades, E. S., Evans, J. C., Larson, M. G., Chen, M. H., Chen, L., Benjamin, E. J., & Levy, D. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012407 · Cited by 1,364
Thygesen, S. K., Christiansen, C. F., Christensen, S., Lash, T. L., & Sørensen, H. T. (2011) · BMC Medical Research Methodology · doi:10.1186/1471-2288-11-83 · Cited by 1,195
Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
Connolly, S. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2476 · Cited by 1,126
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 631
Research works printed but not linked: 1
- National Institute for Health and Care Excellence (NICE). Implantable cardioverter defibrillators and cardiac resynchronisation therapy for arrhythmias and heart failure. NICE Technology Appraisal Guidance 314 (2014).
Cited by
Quartieri, F., Manyam, H., Calò, L., Ebrahim, I. O., Fusco, A. M., Mester, S. W., Cauti, F. M., Park, S., Francia, P., Giovagnoni, M., et al. (2023) · EP Europace · doi:10.1093/europace/euad068 · Cited by 18
Duvillier, L., Demolder, A., Renterghem, S. V., Mey, C. D., West, F., & Pooter, J. D. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16420 · Cited by 5
Mueller-Leisse, J., Hillmann, H. A. K., Iserloh, L., Fruehauf, B., & Duncker, D. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13061564 · Cited by 4
“Formally, the ICD-10-GM code R55 includes syncope as well as collapse, which may have led to the inclusion of patients without actual syncope.”
BackgroundMethodInfluentialPorta‐Sánchez, A., Casado, R., Salvador, O., Sánchez‐Enrique, C., Bayona, S., Sanchez-Borque, P., Campal, J. M. R., & Cabrera, J. Á. (2021) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2021.10.011 · Cited by 3
Saha, S. A., Rosemas, S. C., Sarkar, S., Ramos, V., Radtke, A. P., Majumder, S., Melis, M. D., Zhou, J., & Sims, J. (2025) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.70214 · Cited by 2
Metadata
- Authors
- Perings, C., Wolff, C., Wilk, A., Witthohn, A., Voss, R., & Rybak, K.
- Affiliations
- Katholisches Klinikum Lünen/Werne , St.-Marien-Hospital Lünen (DE)
- Medtronic (Switzerland) (CH)
- Team Gesundheit, Gesellschaft für Gesundheitsmanagement GmbH, Rellinghauser Str. 93, 45128 Essen, Germany
- Medtronic (Germany) (DE)
- Kardiologische Praxis, Kochstedter Kreisstraße 11, 06847 Dessau-Roßlau, Germany
- Corresponding author
- Wolff, Claudia
- Venue
- Journal of Comparative Effectiveness Research
- Publisher
- Becaris Publishing Limited
- Published
- 2021-03
- Volume
- 10
- Issue
- 4
- Pages
- 285-294
- ISSN
- 2042-6305 (ISSN-L)
- 2042-6313
- OpenAlex
- W3122480719
- Cited by
- 7
- References
- 32
- Citations by year
- 2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 2
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Comparative Effectiveness Research (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- implantable loop recorder, unexplained syncope, recurrent syncope, survival, health care costs, cardiac implantable electronic devices, syncope diagnosis, claims data
- MeSH terms
- Aged, Electrodes, Implanted, Female, Humans, Male, Syncope
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Do implantable loop recorders impact the survival of patients with recurrent unexplained syncope? https://app.cochat.ai/papers/10.2217/cer-2020-0242
- The paper
- Perings, C., Wolff, C., Wilk, A., Witthohn, A., Voss, R., & Rybak, K. (2021). Do implantable loop recorders impact the survival of patients with recurrent unexplained syncope? Journal of Comparative Effectiveness Research. https://doi.org/10.2217/cer-2020-0242
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.