Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope
The DOI matches its Crossref record, with a small difference in title or year; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Aims This prospective multicentre observational study assessed the efficacy of specific therapy based on implantable loop recorder (ILR) diagnostic observations in patients with recurrent suspected neurally mediated syncope (NMS). Methods and results Patients with three or more clinically severe syncopal episodes in the last 2 years without significant electrocardiographic and cardiac abnormalities were included. Orthostatic hypotension and carotid sinus syncope were excluded. After ILR implantation, patients were followed until the first documented syncope (Phase I). The ILR documentation of this episode determined the subsequent therapy and commenced Phase II follow-up. Among 392 patients, the 1-year recurrence rate of syncope during Phase I was 33%. One hundred and three patients had a documented episode and entered Phase II: 53 patients received specific therapy [47 a pacemaker because of asystole of a median 11.5 s duration and six anti-tachyarrhythmia therapy (catheter ablation: four, implantable defibrillator: one, anti-arrhythmic drug: one)] and the remaining 50 patients did not receive specific therapy. The 1-year recurrence rate in 53 patients assigned to a specific therapy was 10% (burden 0.07 +/- 0.2 episodes per patient/year) compared with 41% (burden 0.83 +/- 1.57 episodes per patient/year) in the patients without specific therapy (80% relative risk reduction for patients, P = 0.002, and 92% for burden, P = 0.002). The 1-year recurrence rate in patients with pac…
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These patients appear to benefit from permanent pacing.105–112”
In the citing paper
“However, the devices have been shown to improve care in only the subset of patients who are older, have asystole documented on the ILR, and whose tilt test results were negative, probably because many of the diagnoses are of vasovagal syncope.”
In the citing paper
“The number of syncopal events before patients were considered for ILR implantation was close to those reported from EaSyAS and EGSYS 2.”
From Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry (2011) · cites this paper as [13]
In the citing paper
“The population in PICTURE was slightly younger and healthier than those in other syncope studies such as EaSyAS,12 EGSYS 2,13 and ISSUE 2.14”
From Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry (2011) · cites this paper as [13]
In the citing paper
“Similar findings were subsequently observed with ILR use expanded in an early phase of evaluation in patients with recurrent syncope of uncertain origin, in the absence of highrisk criteria and structural heart disease, 176,180-183 and in suspected reflex syncope. 184-186 In particular, an asystolic pause was present during syncope in about 50% of these patients.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [184]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Self-citationGuidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Self-citationGuidelines on management (diagnosis and treatment) of syncope-update 2004. Executive Summary.
Brignole, M., Alboni, P., Benditt, D. G., Bergfeldt, L., Blanc, J., Thomsen, P. E. B., van Dijk, J. G., Fitzpatrick, A. P., Hohnloser, S. H., Janoušek, J., et al. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.09.004 · Cited by 615
Self-citationEvaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Connolly, S. J., Sheldon, R., Thorpe, K. E., Roberts, R. S., Ellenbogen, K. A., Wilkoff, B. L., Morillo, C., Gent, M., & for the VPS II Investigators (2003) · JAMA · doi:10.1001/jama.289.17.2224 · Cited by 500
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Mechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators (2001) · Circulation · doi:10.1161/hc3601.095708 · Cited by 378
Self-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
RAVIELE, A., GIADA, F., MENOZZI, C., SPECA, G., ORAZI, S., GASPARINI, G., SUTTON, R., & BRIGNOLE, M. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.031 · Cited by 323
Self-citationRisk Factors for Syncope Recurrence After a Positive Tilt-Table Test in Patients With Syncope
Sheldon, R., Rose, S., Flanagan, P., Koshman, M. L., & Killam, S. (1996) · Circulation · doi:10.1161/01.cir.93.5.973 · Cited by 232
Cited by
Items 101–200 of 375
Linker, N. J., Voulgaraki, D., Garutti, C., Rieger, G., & Edvardsson, N. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.10.025 · Cited by 21
2020 Clinical practice guidelines for Bradyarrhythmias and conduction disorders
Revishvili, A. S., Artyukhina, Е. А., Глезер, М. Г., Базаев, В. А., Batalov, R. E., Bokeria, L. A., Bokeria, O. L., Davtyan, K. V., Ivanitsky, E. A., Ковалев, А. С., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4448 · Cited by 30
Tilt testing results are influenced by tilt protocol
Zyśko, D., Fedorowski, A., Nilsson, D., Rudnicki, J., Gajek, J. J., Melander, O., & Sutton, R. (2015) · EP Europace · doi:10.1093/europace/euv262 · Cited by 21
“the difference between spontaneous (≈real-life) and tilt test induced syncope both in terms of the presence of cardioinhibitory reflex and duration of asystole, as previously reported by ISSUE study.(3,4) It is noteworthy that in the ISSUE-3 study, the outcomes for patients with an asystolic tilt and with a non-asysto…”
BackgroundResultSelf-citationSyncope and Idiopathic (Paroxysmal) AV Block
Brignole, M., Deharo, J., & Guieu, R. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.012 · Cited by 22
Self-citationImplant Evaluation of an Insertable Cardiac Monitor Outside the Electrophysiology Lab Setting
PACHULSKI, R. T., Cockrell, J. L., Solomon, H., Yang, F., & Rogers, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071544 · Cited by 20
Solbiati, M., Dipaola, F., Villa, P., Seghezzi, S., Casagranda, I., Rabajoli, F., Fiorini, E., Porta, L., Casazza, G., Voza, A., et al. (2019) · Academic Emergency Medicine · doi:10.1111/acem.13842 · Cited by 22
(2008) · Der Kardiologe · doi:10.1007/s12181-008-0115-8 · Cited by 19
Tomson, T. T., & PASSMAN, R. S. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000129 · Cited by 20
Cardiac Monitoring in Patients with Syncope: Making that Elusive Diagnosis
Subbiah, R., Chia, P.-L., Gula, L., Klein, G., Skanes, A., Yee, R., & Krahn, A. (2014) · Current Cardiology Reviews · doi:10.2174/1573403x10666140214120056 · Cited by 19
Syncope: Review of Monitoring Modalities
Krahn, A. D., Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., & Yee, R. K. (2008) · Current Cardiology Reviews · doi:10.2174/157340308783565447 · Cited by 22
“A recent prospective, multicenter observational study (ISSUE 2) investigated the efficacy of therapies based on ILR diagnosis of recurrent suspected neurocardiogenic syncope [32].”
BackgroundApproach to the Patient with Syncope
Benditt, D. G., & Adkisson, W. O. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.09.002 · Cited by 21
Self-citationShould we treat severe vasovagal syncope with a pacemaker?
Sutton, R. (2017) · Journal of Internal Medicine · doi:10.1111/joim.12603 · Cited by 19
Self-citationPotential usage of cardioneuroablation in vagally mediated functional atrioventricular block
Aksu, T., Güler, T. E., Bozyel, S., & Yalın, K. (2019) · SAGE Open Medicine · doi:10.1177/2050312119836308 · Cited by 21
Pacing for neurally mediated syncope: is placebo powerless?
Brignole, M., & Sutton, R. (2007) · EP Europace · doi:10.1093/europace/eul169 · Cited by 20
Self-citationSelecting Appropriate Diagnostic Tools for Evaluating the Patient With Syncope/Collapse
Krahn, A. D., Andrade, J. G., & Deyell, M. W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.003 · Cited by 19
Moya‐Mitjans, À., Rivas‐Gándara, N., Sarrias, A., Pérez‐Rodon, J., & Roca‐Luque, I. (2012) · Revista Española de Cardiología · doi:10.1016/j.recesp.2012.03.005 · Cited by 24
von Scheidt, W., Seidl, K., Dahm, J. B., Schuchert, A., Wolpert, C., & Zabel, M. (2011) · Der Kardiologe · doi:10.1007/s12181-010-0316-9 · Cited by 22
Implantable Diagnostic Monitors in the Early Assessment of Syncope and Collapse
Hong, P. S. G., & Sulke, N. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.009 · Cited by 17
Evaluation of syncope: focus on diagnosis and treatment of neurally mediated syncope
Lee, A. K. Y., & Krahn, A. D. (2016) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2016.1164034 · Cited by 22
“Even with severe suspected neurally mediated syncopal episodes, the use of an ICM contingent on recurrence and documentation of syncope was a safe and effective strategy [7,50-52].”
BackgroundImplantable rhythm devices in the management of vasovagal syncope
Solbiati, M., & Sheldon, R. S. (2014) · Autonomic Neuroscience · doi:10.1016/j.autneu.2014.05.012 · Cited by 19
Use of implantable and external loop recorders in syncope with unknown causes
Tanno, K. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.03.006 · Cited by 17
“This is due to the difficulty of distinguishing between SVT and VT, and the ambiguous P wave [13,21].”
BackgroundInvestigation of optimal position for implantable loop recorders by potential mapping with Reveal DX
Kawashima, A., Tanimoto, F., Nagao, T., Toyoshima, T., & Okuyama, Y. (2014) · Journal of Arrhythmia · doi:10.1016/j.joa.2014.09.005 · Cited by 18
Prospective evaluation of diagnostic work-up in syncope patients: results of the PL-US registry
Kułakowski, P., Lelonek, M., Kryński, T., Bacior, B., Kowalczyk, J., Małkowska, B., Tokarczyk, M., Stypuła, P., Pawlik, T., & Stec, S. M. (2009) · EP Europace · doi:10.1093/europace/eup367 · Cited by 17
Recurrent syncope: differential diagnosis and management
Bennett, M. T., Leader, N., & Krahn, A. D. (2015) · Heart · doi:10.1136/heartjnl-2014-306627 · Cited by 18
Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope
Solbiati, M., Costantino, G., Casazza, G., Dipaola, F., Galli, A., Furlan, R., Montano, N., & Sheldon, R. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011637 · Cited by 15
Diagnosis of Cardiac Arrhythmias
Miller, J. M., & Zipes, D. P. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0398-6.00036-6 · Cited by 15
Drak-Hernández, Y., Toquero-Ramos, J., Fernández, J. M., Pérez-Pereira, E., Castro-Urda, V., & Fernández-Lozano, I. (2013) · Revista Española de Cardiología · doi:10.1016/j.recesp.2013.06.012 · Cited by 14
Quartieri, F., Manyam, H., Calò, L., Ebrahim, I. O., Fusco, A. M., Mester, S. W., Cauti, F. M., Park, S., Francia, P., Giovagnoni, M., et al. (2023) · EP Europace · doi:10.1093/europace/euad068 · Cited by 20
Psychogenic Syncope? A Cautionary Note
Kanjwal, K., Kanjwal, Y., Karabin, B. L., & Grubb, B. P. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02400.x · Cited by 14
Update on the Role of Pacemaker Therapy in Vasovagal Syncope and Carotid Sinus Syndrome
Parry, S. W., & Matthews, I. G. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.10.012 · Cited by 17
Klein‐Wiele, O., Faghih, M., Dreesen, S., Urbien, R., Abdelghafor, M., Kara, K., Schulte-Hermes, M., Garmer, M., Grönemeyer, D. H. W., & Hailer, B. (2016) · Cardiology Journal · doi:10.5603/cj.a2016.0033 · Cited by 17
Efficacy And Safety Of Implantable Loop Recorder: Experience Of A Center.
Silveira, I., Sousa, M. J., Antunes, N., Silva, V. M. D. S., Roque, C., Pinheiro‐Vieira, A., Lagarto, V., Hipólito-Reis, A., Luz, A., & Torres, S. (2016) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1425 · Cited by 18
WENZKE, K. E., WALSH, K. E., Kalscheur, M. M., Wasmund, S. L., Page, R. L., Brignole, M., & Hamdan, M. H. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13069 · Cited by 15
Self-citationJoza, J. E., da Rosa, L. G. B., AlTurki, A., Anglesio, V., Sánchez-Somonte, P., Poletaev, V., Bernier, M., Verma, A., & Essebag, V. (2024) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2024.101360 · Cited by 16
“The mechanism of spontaneous VVS documented by implantable loop recorder (ILR) is reproducible within patients [5,6], and was found to be asystole in approximately half of syncopal events in the International Study on Syncope of Uncertain /Etiology 2 (ISSUE 2) study [7].”
BackgroundSutton, R. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00048 · Cited by 15
Self-citationTilt-induced cardioinhibitory syncope: a follow-up study in 16 patients
Guaraldi, P., Buonaura, G. C., Terlizzi, R., Cecere, A., Solieri, L., Barletta, G., & Cortelli, P. (2011) · Clinical Autonomic Research · doi:10.1007/s10286-011-0153-3 · Cited by 18
“Although only limited information is available as regards the correspondence between induced and clinical episodes of asystole [15, 16], we believe that the use of 65 passive tilt test up to 30 min without additional provocative agents, despite being less sensitive has a greater specificity and better reflects the con…”
Shanmugam, N., & Liew, R. (2012) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.v41n3p115 · Cited by 14
Tilt-table testing: transient loss of consciousness discriminator or epiphenomenon?
Petkar, S., & Fitzpatrick, A. P. (2008) · EP Europace · doi:10.1093/europace/eun100 · Cited by 16
Guo, Y., Chen, X., Zeng, T., Wang, L., & Cen, L. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.667171 · Cited by 11
Strano, S., Toni, D., Ammirati, F., Sanna, T., Tomaino, M., Brignole, M., Mazza, A., Nguyen, B. L., Bonaventura, C. D., Ricci, R. P., et al. (2019) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000866 · Cited by 13
Self-citationThe implantable loop recorder: a critical review
Graf, D., Pascale, P., Pruvot, E., & Iglesias, F. (2009) · Kardiovask Med · doi:10.4414/cvm.2009.01406 · Cited by 14
Treatment of persistent sinus bradycardia with intermittent symptoms: are guidelines clear?
Alboni, P., Gianfranchi, L., & Brignole, M. (2009) · EP Europace · doi:10.1093/europace/eup014 · Cited by 12
Self-citationTilt Table Testing and Implantable Loop Recorders for Syncope
Sheldon, R. S. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.10.009 · Cited by 12
The management of syncope in older adults.
Ungar, A., Morrione, A., Rafanelli, M., Ruffolo, E., Brunetti, M. A., Chisciotti, V. M., Masotti, G., Rosso, A. D., & Marchionni, N. (2009) · PubMed · Cited by 12
Current treatment of recurrent vasovagal syncope: between evidence-based therapy and common sense
Alboni, P., Dinelli, M., Gianfranchi, L., & Pacchioni, F. (2007) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e3280122d50 · Cited by 11
Syncope: Etiology and diagnostic approach
Hanna, E. B. (2014) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.81a.13152 · Cited by 14
The Value of Tilt Testing and Autonomic Nervous System Assessment
Sutton, R. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.003 · Cited by 11
Self-citationThe Implantable Loop Recorder: Current Uses, Future Directions
Kanjwal, K., Figueredo, V. M., Karabin, B. L., & Grubb, B. P. (2011) · Cited by 12
Treatment of Neurocardiogenic Syncope: From Conservative to Cutting-edge
Gampa, A., & Upadhyay, G. A. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090702 · Cited by 10
Diagnosis and prevention of the vasodepressor type of neurally mediated syncope in Japanese patients
Hasegawa, M., Komiyama, T., Ayabe, K., Sakama, S., Sakai, T., Lee, K. H., Morise, M., Yagishita, A., Amino, M., Sasaki, A., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0251450 · Cited by 11
Chang, W.-L., Hou, C. J., Wei, S.-P., Tsai, J., Chen, Y.-J., Chen, M., Chuech, C.-C., Hung, C., Huang, M.-Y., Lee, C.-H., et al. (2015) · International journal of gerontology · doi:10.1016/j.ijge.2015.06.002 · Cited by 9
Loop recorders for syncope evaluation: what is the evidence?
Cheung, C. C., & Krahn, A. D. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1243463 · Cited by 8
“Earlier implantation of ILR in the work-up of unexplained syncope has been advocated in some studies, with reports of fewer investigations, lower rates of injury and hospitalization, and equivalent efficacy, compared to delayed implantation [50,51].”
ResultValue of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.004 · Cited by 11
Guía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)73132-x · Cited by 29
Self-citationMoya‐Mitjans, À., Roca‐Luque, I., Pascual, J. F., Pérez‐Rodon, J., & Rivas‐Gándara, N. (2012) · Cardiology Clinics · doi:10.1016/j.ccl.2012.10.001 · Cited by 9
Implantable Cardiac Monitors: Evolution Through Disruption
Sandesara, C. M., Gopinathannair, R., & Olshansky, B. (2017) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2017.080903 · Cited by 8
“Other trials have shown ICMs to be superior to an otherwise-standard evaluation.(14,15) These data indicate that prolonged monitoring was necessary to capture a diagnosis in syncope patients.”
BackgroundRaj, S. R. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-386525-0.00070-6 · Cited by 9
Single center experience in Japanese patients with syncope
Onuki, T., Ito, H., Ochi, A., Chiba, Y., Kawasaki, S., Onishi, Y., Munetsugu, Y., Kikuchi, M., Minoura, Y., Watanabe, N., et al. (2015) · Journal of Cardiology · doi:10.1016/j.jjcc.2014.12.009 · Cited by 11
Syncope: Approaches to Diagnosis and Management
Palaniswamy, C., Aronow, W. S., Agrawal, N., Balasubramaniyam, N., & Lakshmanadoss, U. (2012) · American Journal of Therapeutics · doi:10.1097/mjt.0b013e318256ed0f · Cited by 12
“The recent ISSUE II trial reported that permanent pacing in patients with periods of asystole had a significant reduction in the frequency of syncope.(58) Patients with the cardioinhibitory or mixed forms of carotid sinus hypersensitivity may benefit also from permanent pacing.”
MethodTrends in Subcutaneous Cardiac Monitoring Technology
Kohno, R., Nantsupawat, T., & Benditt, D. G. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090703 · Cited by 8
Self-citationEvaluation of Syncope and Palpitations in Women
Misiri, J., Candler, S. A., & Kusumoto, F. M. (2011) · Journal of Women s Health · doi:10.1089/jwh.2010.2636 · Cited by 8
The implantable loop recorder in older patients with syncope: is sooner better?
Parry, S. W., & Matthews, I. (2010) · Age and Ageing · doi:10.1093/ageing/afq023 · Cited by 10
Economic value of insertable cardiac monitors in unexplained syncope in the United States
Sutton, B. S., Bermingham, S. L., Diamantopoulos, A., Rosemas, S. C., Tsintzos, S. I., Xia, Y., & Reynolds, M. R. (2021) · Open Heart · doi:10.1136/openhrt-2020-001263 · Cited by 7
Cardiac sarcoidosis resembling panic disorder: a case report
Tokumitsu, K., Demachi, J., Yamanoi, Y., Oyama, S., Takeuchi, J. S., Yachimori, K., & Yasui‐Furukori, N. (2017) · BMC Psychiatry · doi:10.1186/s12888-016-1184-z · Cited by 7
“To perform an accurate diagnosis earlier, it may have been useful to use an implantable loop recorder to analyze electrocardiographic findings during attacks [6].”
MethodImplantable Loop Recorders—Syncope, Cryptogenic Stroke, Atrial Fibrillation
Mittal, S. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.006 · Cited by 7
Jhanjee, R., Can, I., & Benditt, D. G. (2009) · Disease-a-Month · doi:10.1016/j.disamonth.2009.04.004 · Cited by 8
Self-citationClinical Utility of Implantable Loop Recorders
Houmsse, M., Ishola, A., & Daoud, E. G. (2014) · Postgraduate Medicine · doi:10.3810/pgm.2014.03.2738 · Cited by 7
Pacing for vasovagal syncope: Tips for use in practice
Morillo, C. A., & Brignole, M. (2022) · Autonomic Neuroscience · doi:10.1016/j.autneu.2022.102998 · Cited by 9
Self-citationVasovagal syncope and vasovagal disease.
Brignole, M. (2008) · PubMed · Cited by 8
Self-citation2025 Clinical practice guidelines for Bradyarrhythmias and conduction disorders
Revishvili, A. S. H., Glezer, M. G., Artyukhina, Е. А., Базаев, В. А., Batalov, R. E., Bockeria, L. A., Davtyan, K. V., Lebedev, D. S., Лебедева, В. К., Lyubimtseva, T. A., et al. (2026) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2025-6669 · Cited by 8
Reed, M. J., Grubb, N. R., Lang, C., Goodacre, S. W., O’Brien, R., Weir, C. J., Thokala, P., Freeman, N., Blackstock, C., Dinsmore, L., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-069530 · Cited by 6
Current Management of Syncope: Focus on Drug Therapy
Venugopal, D., Jhanjee, R., & Benditt, D. G. (2007) · American Journal of Cardiovascular Drugs · doi:10.2165/00129784-200707060-00003 · Cited by 7
Self-citationDiagnostic algorithm for syncope
Mereu, R., Sau, A., & Lim, P. B. (2014) · Autonomic Neuroscience · doi:10.1016/j.autneu.2014.05.008 · Cited by 8
“A recent meta-analysis of HUTT found a sensitivity of AC C EP TE D M AN U SC R IP T 37% and a specificity of 96% when performed without drug administration and a sensitivity of 59% and a specificity of 96% when performed with nitroglycerine (Forleo et al., 2013).”
BackgroundMethodInfluentialImplantable Loop Recorders for Cardiac Dysrhythmia Monitoring
Akella, K., Murtaza, G., Rocca, D. G. D., Kodwani, N., Gopinathannair, R., Natale, A., & Lakkireddy, D. (2020) · Future Cardiology · doi:10.2217/fca-2020-0035 · Cited by 7
Syncope in congestive heart failure.
Gopinathannair, R., Mazur, A., & Olshansky, B. (2008) · PubMed · Cited by 6
Aspects of Pacemakers - Functions and Interactions in Cardiac and Non-Cardiac Indications
Vonend, O., & Eckert, S. (2011) · InTech eBooks · doi:10.5772/845 · Cited by 7
CURRENT METHODS OF AMBULATORY ELECTROCARDIOGRAM MONITORING. TECHNICAL ASPECTS
Pervova, E. V. (2017) · The Clinician · doi:10.17650/1818-8338-2016-10-4-16-28 · Cited by 7
Emerging concepts in diagnosis and treatment of syncope by pacing
Sutton, R., Deharo, J., Brignole, M., & Hamdan, M. H. (2018) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2018.01.009 · Cited by 6
Self-citationAngaran, P., Klein, G. J., Yee, R. K., Skanes, A. C., Gula, L. J., Leong‐Sit, P., & Krahn, A. D. (2011) · Neurologic Clinics · doi:10.1016/j.ncl.2011.07.005 · Cited by 7
Usefulness of implantable loop recorder in a patient with syncope during bathing
Nakao, M., & Kobayashi, S. (2012) · Journal of Arrhythmia · doi:10.1016/j.joa.2012.10.001 · Cited by 6
“The decreasing blood pressure supported the diagnosis of mild vasodepressor NMS.”
BackgroundInfluentialSchernthaner, C., Danmayr, F., Altenberger, J., Pichler, M., & Strohmer, B. (2008) · PubMed · Cited by 6
Sutton, R. (2012) · Heart · doi:10.1136/heartjnl-2012-303062 · Cited by 8
Self-citationThe Rate of Asystolic Reflex Syncope Is Not Influenced by Age
Brignole, M., Groppelli, A., Russo, V., Fedorowski, A., van Dijk, G., & Alboni, P. (2024) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2023.11.021 · Cited by 6
Self-citationSyncope update 2013: diagnosis and treatment
Kułakowski, P. (2013) · Kardiologia Polska · doi:10.5603/kp.2013.0031 · Cited by 7
Pacing for Patients Suffering From Cardioinhibitory Vasovagal Syncope Using the Closed-Loop System
Barón‐Esquivias, G., Barón-Solís, C., & Ordóñez, A. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2019.00192 · Cited by 6
“This study was a registry rather than a randomized, doubleblind, controlled trial (10).”
BackgroundExperience With Implantable Loop Recorders for Recurrent Unexplained Syncope
Brignole, M. (2008) · Congestive Heart Failure · doi:10.1111/j.1751-7133.2008.tb00014.x · Cited by 4
Self-citationSau, A., Mereu, R., Taraborrelli, P., Dhutia, N. M., Willson, K., Hayat, S. A., Francis, D. P., Sutton, R., & Lim, P. B. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.10.090 · Cited by 6
Self-citationCurrent concepts in the evaluation and management of syncope
Kuriachan, V. P., & Sheldon, R. S. (2008) · Current Cardiology Reports · doi:10.1007/s11886-008-0061-x · Cited by 6
The Role of the Syncope Management Unit
Kenny, R. A., Rice, C. P., & Byrne, L. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.016 · Cited by 5
Remote Device Management in Patients with Cardiac Complaints
Burri, H., & Varma, N. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.05.005 · Cited by 5
The implantable loop recorder in children: searching for indications
Pass, R. H., & Liberman, L. (2008) · Heart · doi:10.1136/hrt.2007.126276 · Cited by 5
Adkisson, W. O., & Benditt, D. G. (2012) · EP Europace · doi:10.1093/europace/eus224 · Cited by 5
Self-citationSalih, H., Monsel, F., Sergent, J., & Amara, W. (2012) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2012.08.033 · Cited by 4
Syncope and Idiopathic (Paroxysmal) AV Block
Brignole, M., Deharo, J., & Guieu, R. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.008 · Cited by 4
Self-citationKenny, R. A. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-6231-8.10046-7 · Cited by 5
Implantable loop recorder in Brugada syndrome: Insights from a single-center experience
Arabia, G., Cerini, M., Cersosimo, A., Vinciguerra, P., Calvi, E., Mitacchione, G., Aboelhassan, M., Giacopelli, D., & Curnis, A. (2024) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2024.101371 · Cited by 4
“Several studies have demonstrated the recurrence of vasovagal syncope with sinus rhythm recorded by ILRs, while ventricular arrhythmias have been rarely reported [11 – 14].”
ResultReflexsynkopen und Synkopen bei orthostatischer Hypotonie
Simonis, G., Gerk, U., Pabst, F., Machetanz, J., Spitzer, S. G., & Schellong, S. (2014) · Der Internist · doi:10.1007/s00108-014-3552-4 · Cited by 4
Numeroso, F., Mossini, G., Lippi, G., & Cervellin, G. (2017) · Acta cardiologica. Supplementum · doi:10.1080/00015385.2017.1362146 · Cited by 5
Steinberg, C., Bennett, M. T., & Krahn, A. D. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_5 · Cited by 6
Different Types of Syncope Presenting to Clinic: Do We Miss Cardiac Syncope?
Al-Busaidi, I. S., & Jardine, D. L. (2019) · Heart Lung and Circulation · doi:10.1016/j.hlc.2019.09.008 · Cited by 5
Metadata
- Authors
- Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P.
- Affiliations
- Presidio Ospedaliero (IT)
- Royal Brompton & Harefield NHS Foundation Trust (GB)
- Santa Maria Nuova Hospital (IT)
- University of Amsterdam (NL)
- Vivantes Klinikum (DE)
- University Hospital of Heraklion (GR)
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-03-28
- Volume
- 27
- Issue
- 9
- Pages
- 1085-1092
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2143491599
- Semantic Scholar
- c9d27f15e5d1ad4d72f98e17ec4271db925253f6
- Cited by
- 376
- References
- 22
- Citations by year
- 2026: 9 · 2025: 5 · 2024: 8 · 2023: 7 · 2022: 10 · 2021: 15 · 2020: 10 · 2019: 11 · 2018: 17 · 2017: 25 · 2016: 20 · 2015: 20 · 2014: 29 · 2013: 37 · 2012: 22
- FWCI
- 26.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- HighWire Press Open Archive (submittedVersion)
- Pure Amsterdam UMC (submittedVersion)
- Funders
- Medtronic
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- neurally mediated syncope, implantable loop recorder, syncope recurrence, pacemaker implantation, catheter ablation, implantable cardioverter-defibrillator, specific therapy
- MeSH terms
- Adult, Aged, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Cardiac Pacing, Artificial, Electrodes, Implanted, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Recurrence, Risk Factors, Catheter Ablation, Syncope, Vasovagal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.