Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope
The DOI matches its Crossref record, with a small difference in title or year; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Aims This prospective multicentre observational study assessed the efficacy of specific therapy based on implantable loop recorder (ILR) diagnostic observations in patients with recurrent suspected neurally mediated syncope (NMS). Methods and results Patients with three or more clinically severe syncopal episodes in the last 2 years without significant electrocardiographic and cardiac abnormalities were included. Orthostatic hypotension and carotid sinus syncope were excluded. After ILR implantation, patients were followed until the first documented syncope (Phase I). The ILR documentation of this episode determined the subsequent therapy and commenced Phase II follow-up. Among 392 patients, the 1-year recurrence rate of syncope during Phase I was 33%. One hundred and three patients had a documented episode and entered Phase II: 53 patients received specific therapy [47 a pacemaker because of asystole of a median 11.5 s duration and six anti-tachyarrhythmia therapy (catheter ablation: four, implantable defibrillator: one, anti-arrhythmic drug: one)] and the remaining 50 patients did not receive specific therapy. The 1-year recurrence rate in 53 patients assigned to a specific therapy was 10% (burden 0.07 +/- 0.2 episodes per patient/year) compared with 41% (burden 0.83 +/- 1.57 episodes per patient/year) in the patients without specific therapy (80% relative risk reduction for patients, P = 0.002, and 92% for burden, P = 0.002). The 1-year recurrence rate in patients with pac…
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These patients appear to benefit from permanent pacing.105–112”
In the citing paper
“However, the devices have been shown to improve care in only the subset of patients who are older, have asystole documented on the ILR, and whose tilt test results were negative, probably because many of the diagnoses are of vasovagal syncope.”
In the citing paper
“The number of syncopal events before patients were considered for ILR implantation was close to those reported from EaSyAS and EGSYS 2.”
From Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry (2011) · cites this paper as [13]
In the citing paper
“The population in PICTURE was slightly younger and healthier than those in other syncope studies such as EaSyAS,12 EGSYS 2,13 and ISSUE 2.14”
From Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry (2011) · cites this paper as [13]
In the citing paper
“Similar findings were subsequently observed with ILR use expanded in an early phase of evaluation in patients with recurrent syncope of uncertain origin, in the absence of highrisk criteria and structural heart disease, 176,180-183 and in suspected reflex syncope. 184-186 In particular, an asystolic pause was present during syncope in about 50% of these patients.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [184]
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Self-citationGuidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Self-citationGuidelines on management (diagnosis and treatment) of syncope-update 2004. Executive Summary.
Brignole, M., Alboni, P., Benditt, D. G., Bergfeldt, L., Blanc, J., Thomsen, P. E. B., van Dijk, J. G., Fitzpatrick, A. P., Hohnloser, S. H., Janoušek, J., et al. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.09.004 · Cited by 615
Self-citationEvaluation and Outcome of Patients with Syncope
KAPOOR, W. N. (1990) · Medicine · doi:10.1097/00005792-199005000-00004 · Cited by 539
Connolly, S. J., Sheldon, R., Thorpe, K. E., Roberts, R. S., Ellenbogen, K. A., Wilkoff, B. L., Morillo, C., Gent, M., & for the VPS II Investigators (2003) · JAMA · doi:10.1001/jama.289.17.2224 · Cited by 500
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Mechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators (2001) · Circulation · doi:10.1161/hc3601.095708 · Cited by 378
Self-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
RAVIELE, A., GIADA, F., MENOZZI, C., SPECA, G., ORAZI, S., GASPARINI, G., SUTTON, R., & BRIGNOLE, M. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.031 · Cited by 323
Self-citationRisk Factors for Syncope Recurrence After a Positive Tilt-Table Test in Patients With Syncope
Sheldon, R., Rose, S., Flanagan, P., Koshman, M. L., & Killam, S. (1996) · Circulation · doi:10.1161/01.cir.93.5.973 · Cited by 232
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Self-citationDeveloped in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citation2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citationAuthors/Task Force Members, Brignole, M., Auricchio, A., Baron-Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O.-A., Cleland, J., Deharo, J.-C., Delgado, V., et al. (2013) · Europace · doi:10.1093/europace/eut206 · Cited by 1,124
“In the ISSUE 2 and ISSUE 3 trials, DDD pacing with rate hysteresis (with specific rate-drop algorithm) was used in patients with documented reflex asystolic syncope, but these trials did not consider a comparison with other pacing modalities.(5,19) In all trials of cardiac pacing in tilt-positive vasovagal patients, d…”
MethodSelf-citationSheldon, R. S., Grubb, B. P., Olshansky, B., Shen, W.-K., Calkins, H., Brignole, M., Raj, S. R., Krahn, A. D., Morillo, C. A., Stewart, J. M., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.03.029 · Cited by 1,013
Self-citation2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citationAuthors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Self-citation2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., De Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martiın, A., et al. (2018) · Kardiologia Polska · doi:10.5603/kp.2018.0161 · Cited by 476
Self-citationBrignole, M., Menozzi, C., Moya, A., Andresen, D., Blanc, J. J., Krahn, A. D., Wieling, W., Beiras, X., Deharo, J. C., Russo, V., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.082313 · Cited by 437
Self-citationIndications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
“the initial evaluation, either positive or negative response during tilt testing, in order to capture an asystolic event when cardiac pacing would be justified by the severity and unpredictability of symptoms and lack of alternative therapies.(7) † Diagnosis of syncope not established, just suspected:”
BackgroundMethodInfluentialSelf-citationAuthors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · Europace · doi:10.1093/europace/eum189 · Cited by 291
Self-citationGuía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya, Á., Sutton, R., Ammirati, F., Blanc, J.-J., Brignole, M., Dahm, J. B., Deharo, J.-C., Gajek, J., Gjesdal, K., Krahn, A., et al. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)73541-8 · Cited by 276
Self-citationEdvardsson, N., Frykman, V., van Mechelen, R., Mitro, P., Mohii-Oskarsson, A., Pasquie, J.-L., Ramanna, H., Schwertfeger, F., Ventura, R., Voulgaraki, D., et al. (2011) · Europace · doi:10.1093/europace/euq418 · Cited by 250
2013 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy
(2014) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.11.003 · Cited by 196
“В исследованиях ISSUE 2 и ISSUE 3 DDD электростимуляция с частотным гистерезисом (со специальным алгоритмом для внезапного падения частоты ритма) использовалась у пациентов с документированными рефлекторными асистолическими синкопальными состояниями, но в этих исследованиях не проводилось сравнение с другими режимами…”
Self-citationSouthcott, M., MacVittie, K., Halámek, J., Halámková, L., Jemison, W. D., Lobel, R., & Katz, E. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp50929j · Cited by 189
VAN DIJK, N., BOER, K. R., COLMAN, N., BAKKER, A., STAM, J., VAN GRIEKEN, J. J. M., WILDE, A. A. M., LINZER, M., REITSMA, J. B., & WIELING, W. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00984.x · Cited by 164
Self-citationThe semiology of tilt-induced reflex syncope in relation to electroencephalographic changes
van Dijk, J. G., Thijs, R. D., van Zwet, E., Tannemaat, M. R., van Niekerk, J., Benditt, D. G., & Wieling, W. (2014) · Brain · doi:10.1093/brain/awt332 · Cited by 160
“However, the proportion of cases with asystole 43 s and the duration of asystole in our study were similar to those in the ISSUE-2 and ISSUE-3 trials (Brignole et al., 2006, 2012).”
ResultSelf-citationSyncope Due to Idiopathic Paroxysmal Atrioventricular Block
Brignole, M., Deharo, J.-C., De Roy, L., Menozzi, C., Blommaert, D., Dabiri, L., Ruf, J., & Guieu, R. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.045 · Cited by 147
Self-citationBrignole, M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl164 · Cited by 145
Self-citationESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Nielsen, J. C., Petersen, H. H., Karlsen, F. M., Chri, L. S., & Haarbo, J. (2014) · Cited by 146
Brignole, M., Donateo, P., Tomaino, M., Massa, R., Iori, M., Beiras, X., Moya, A., Kus, T., Deharo, J. C., Giuli, S., et al. (2014) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.113.001103 · Cited by 127
Self-citationHolter Monitoring and Loop Recorders: From Research to Clinical Practice
Galli, A., Ambrosini, F., & Lombardi, F. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.17.2 · Cited by 143
Implantable loop recorder in clinical practice
Bisignani, A., Bonis, S. D., Mancuso, L., Ceravolo, G., & Bisignani, G. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12142 · Cited by 128
Telemedicine in Pediatric Cardiology: A Scientific Statement From the American Heart Association
Satou, G. M., Rheuban, K. S., Alverson, D. C., Lewin, M., Mahnke, C. B., Marcin, J. P., Martin, G. R., Mazur, L. S., Sahn, D. J., Shah, S. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000478 · Cited by 114
The management of vasovagal syncope
Kenny, R. A., & McNicholas, T. (2016) · QJM · doi:10.1093/qjmed/hcw089 · Cited by 127
Sulke, N., Sugihara, C., Hong, P., Patel, N., & Freemantle, N. (2016) · Europace · doi:10.1093/europace/euv228 · Cited by 95
“Successful interventions based on an ECG diagnosis should increase the time to second syncope.(8,13,14) In patients who reported a second syncopal event, only subjects who received an ILR had a significant increase in the time to second syncope.”
MethodFlammang, D., Church, T. R., De Roy, L., Blanc, J.-J., Leroy, J., Mairesse, G. H., Otmani, A., Graux, P. J., Frank, R., Purnode, P., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.022855 · Cited by 93
Podoleanu, C., DaCosta, A., Defaye, P., Taieb, J., Galley, D., Bru, P., Maury, P., Mabo, P., Boveda, S., Cellarier, G., et al. (2014) · Archives of Cardiovascular Diseases · doi:10.1016/j.acvd.2014.05.009 · Cited by 93
Locati, E. T., Moya, A., Oliveira, M., Tanner, H., Willems, R., Lunati, M., & Brignole, M. (2016) · Europace · doi:10.1093/europace/euv311 · Cited by 95
“Syncope and palpitations tend to occur in clusters, with higher reoccurrence rate early after an event, thus an early use of long-term ECG monitoring may increase the likelihood of clinical diagnosis.(1,10) The SYNARR-Flash study (Monitoring of SYNcopes and/or sustained palpitations of suspected ARRhythmic origin; cli…”
BackgroundSelf-citation2013 ESC GUIDELINES ON CARDIAC PACING AND CARDIAC RESYNCHRONIZATION THERAPY
Brignole, M., Auricchio, A., Barón‐Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O. A., Cleland, J. G. F., Deharo, J., Delgado, V., Elliot, P. M., et al. (2014) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2014-4-5-63 · Cited by 95
Self-citationSantini, M., Castro, A., Giada, F., Ricci, R., Inama, G., Gaggioli, G., Calò, L., Orazi, S., Viscusi, M., Chiodi, L., et al. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.112.975102 · Cited by 84
How to avoid a misdiagnosis in patients presenting with transient loss of consciousness
Petkar, S., Cooper, P. N., & Fitzpatrick, A. P. (2006) · Postgraduate Medical Journal · doi:10.1136/pgmj.2006.046565 · Cited by 108
Is vasovagal syncope a disease?
Alboni, P., Brignole, M., & degli Uberti, E. C. (2007) · EP Europace · doi:10.1093/europace/eul179 · Cited by 82
“In this regard, a specific therapy guided by electrocardiographic examination at the time of syncope recurrence has proved effective in relieving recurrences.(52) In contrast, no specific therapy is generally warranted in most subjects affected by isolated VVS.”
Self-citationSUMNER, G. L., ROSE, M. S., KOSHMAN, M. L., RITCHIE, D., SHELDON, R. S., & for the Prevention of Syncope Trial Investigators (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01848.x · Cited by 80
Brignole, M., Ammirati, F., Arabia, F., Quartieri, F., Tomaino, M., Ungar, A., Lunati, M., Russo, V., Del Rosso, A., & Gaggioli, G. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv069 · Cited by 80
“Major injuries (fractures, brain concussion) 50/234 (21) 7/63 (11) 6/27 (22) 32/129 (25)”
BackgroundSelf-citationMaggi, R., Menozzi, C., Brignole, M., Podoleanu, C., Iori, M., Sutton, R., Moya, A., Giada, F., Orazi, S., & Grovale, N. (2007) · EP Europace · doi:10.1093/europace/eum092 · Cited by 79
Self-citationDiagnosis and treatment of syncope
Brignole, M. (2006) · Heart · doi:10.1136/hrt.2005.080713 · Cited by 87
Self-citationFURUKAWA, T., MAGGI, R., BERTOLONE, C., FONTANA, D., & BRIGNOLE, M. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02133.x · Cited by 77
Self-citationBrignole, M., Arabia, F., Ammirati, F., Tomaino, M., Quartieri, F., Rafanelli, M., Del Rosso, A., Rita Vecchi, M., Russo, V., & Gaggioli, G. (2016) · Europace · doi:10.1093/europace/euv343 · Cited by 76
Self-citationNew Concepts in the Assessment of Syncope
Brignole, M., & Hamdan, M. H. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.11.056 · Cited by 87
“Pooled data from 14 studies (8–21) including a total of 1,598 patients showed an average diagnostic yield of 32% over an observation period of 18 months and 43% (20), 49% (8), and approximately 50% (21) when the monitoring period was up to 2 years.”
BackgroundSelf-citationManagement of syncope: clinical and economic impact of a Syncope Unit
Ammirati, F., Colaceci, R., Cesario, A., Strano, S., Della Scala, A., Colangelo, I., De Santo, T., Toscano, E., Ricci, R., & Santini, M. (2008) · Europace · doi:10.1093/europace/eun061 · Cited by 73
The Reveal LINQ insertable cardiac monitor
Tomson, T. T., & Passman, R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.953059 · Cited by 72
“The ISSUE 2 study was a prospective multicenter observational study that also investigated the early application of ICMs in patients with recurrent syncope suspected to be neurally mediated [27].”
BackgroundVIRAG, N., Sutton, R., Vetter, R., Markowitz, T., & Erickson, M. K. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.07.018 · Cited by 77
Self-citationSyncope and paroxysmal atrioventricular block
Aste, M., & Brignole, M. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.03.008 · Cited by 80
“In the ISSUE 2, SUP 2, and ISSUE 3 trials [29,33,34], dual-chamber cardiac pacing in patients with syncope and documentation of asystolic pause (either sinus arrest or AVB) by means of ECG monitoring was associated with a not infrequent recurrence rate of syncopal events (12–25% at 2-year follow-up).”
BackgroundSelf-citationImplications of mechanism of bradycardia on response to pacing in patients with unexplained syncope
Sud, S., Klein, G. J., Skanes, A. C., Gula, L. J., Yee, R., & Krahn, A. D. (2007) · EP Europace · doi:10.1093/europace/eum020 · Cited by 66
“In the recently published ISSUE 2 study, however, hypertension, age, and the absence of pacemaker therapy were most predictive of recurrent syncope (after pacemaker insertion).(30) These differences may be explained by minor differences in methodology; all patients in our study received a pacemaker, and the analysis w…”
MethodDrugs and pacemakers for vasovagal, carotid sinus and situational syncope
Romme, J. J., Reitsma, J. B., Black, C. N., Colman, N., Scholten, R. J., Wieling, W., & Van Dijk, N. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004194.pub3 · Cited by 65
Self-citationThe Steering Committee of the ISSUE 3 Study (2007) · Europace · doi:10.1093/europace/eul135 · Cited by 65
Cardioneuroablation for Treatment of Atrioventricular Block
Aksu, T., Gopinathannair, R., Bozyel, S., Yalın, K., & Gupta, D. (2021) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.121.010018 · Cited by 73
Cardiovascular Disorders and Falls Among Older Adults: A Systematic Review and Meta-Analysis
Bourke, R., Doody, P., Pérez, S., Moloney, D. J., Lipsitz, L. A., & Kenny, R. A. (2023) · The Journals of Gerontology Series A · doi:10.1093/gerona/glad221 · Cited by 84
Mechanism of syncope without prodromes with normal heart and normal electrocardiogram
Brignole, M., Guieu, R., Tomaino, M., Iori, M., Ungar, A., Bertolone, C., Unterhuber, M., Bottoni, N., Tesi, F., & Claude Deharo, J. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2016.08.046 · Cited by 59
“Statistical analysis The probability of diagnostic asystolic ECG documentation in ISSUE-2 and ISSUE-3 was 17% at 1 year.(7,8) In the absence of any data on the prevalence of asystolic pauses in patients with unexplained syncope, no prodromes, and a normal heart, we planned to enroll 60 patients.”
BackgroundMethodSelf-citationRuwald, M. H., Hansen, M. L., Lamberts, M., Hansen, C. M., Numé, A.-K., Vinther, M., Køber, L., Torp-Pedersen, C., Hansen, J., & Gislason, G. H. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.07.041 · Cited by 59
Ungar, A., Sgobino, P., Russo, V., Vitale, E., Sutton, R., Melissano, D., Beiras, X., Bottoni, N., Ebert, H. H., Gulizia, M., et al. (2013) · Heart · doi:10.1136/heartjnl-2013-304399 · Cited by 58
Self-citationEffectiveness of remote monitoring in the management of syncope and palpitations
Furukawa, T., Maggi, R., Bertolone, C., Ammirati, F., Santini, M., Ricci, R., Giada, F., & Brignole, M. (2011) · Europace · doi:10.1093/europace/euq503 · Cited by 57
“In patients with recurrent reflex syncope, a syncopal relapse was documented after 3 months (interquartile range 1–7).(3) In patients with structural heart disease and negative work-up, a syncopal relapse was documented after 6+5 months.”
BackgroundSelf-citationImplantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope
Solbiati, M., Costantino, G., Casazza, G., Dipaola, F., Galli, A., Furlan, R., Montano, N., & Sheldon, R. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011637.pub2 · Cited by 56
Benditt, D. G., & Nguyen, J. T. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.065 · Cited by 60
Self-citationLocati, E. T., Vecchi, A. M., Vargiu, S., Cattafi, G., & Lunati, M. (2014) · Europace · doi:10.1093/europace/eut337 · Cited by 53
Kubala, M., Aïssou, L., Traullé, S., Gugenheim, A.-L., & Js, H. (2011) · EP Europace · doi:10.1093/europace/eur319 · Cited by 57
“2005 201 43 Brignole et al.(13) 2006 392 33 Edvardsson et al.”
BackgroundInfluentialHigh Remission Rates in Vasovagal Syncope
Pournazari, P., Sahota, I. S., & Sheldon, R. S. (2016) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2016.10.012 · Cited by 59
“(8) (2006) (phase 1) OBS – NA 2 2 392 Brignole et al.”
Pezawas, T., Stix, G., Kastner, J., Schneider, B., Wolzt, M., & Schmidinger, H. (2008) · Heart · doi:10.1136/hrt.2007.116616 · Cited by 52
Likelihood of injury due to vasovagal syncope: a systematic review and meta-analysis
Jorge, J. G., Raj, S. R., Teixeira, P. S., Teixeira, J. A. C., & Sheldon, R. S. (2021) · EP Europace · doi:10.1093/europace/euab041 · Cited by 55
New insights in diagnostics and therapies in syncope: a novel approach to non-cardiac syncope
Brignole, M., & Rivasi, G. (2021) · Heart · doi:10.1136/heartjnl-2020-318261 · Cited by 51
Self-citationPostural syncope: mechanisms and management
Vaddadi, G., Lambert, E., Corcoran, S. J., & Esler, M. D. (2007) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2007.tb01248.x · Cited by 48
Evidence-based treatment for vasovagal syncope
Kuriachan, V., Sheldon, R. S., & Platonov, M. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.08.023 · Cited by 47
Brignole, M., Deharo, J. C., Menozzi, C., Moya, A., Sutton, R., Tomaino, M., & Ungar, A. (2018) · EP Europace · doi:10.1093/europace/eux321 · Cited by 39
Self-citationImproved Arrhythmia Detection in Implantable Loop Recorders
Brignole, M., Bellardine, C. L., Thomsen, P. E. B., Sutton, R., Moya‐Mitjans, À., STADLER, R. W., Cao, J. J., Messier, M., & Huikuri, H. V. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01156.x · Cited by 48
Self-citationPredicting the cause of syncope from clinical history in patients undergoing prolonged monitoring
Sud, S., Klein, G. J., Skanes, A. C., Gula, L. J., Yee, R., & Krahn, A. D. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.035 · Cited by 43
Clinical Classification of Syncope
Sutton, R. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.005 · Cited by 48
Self-citationInsertable cardiac monitors: current indications and devices
Sakhi, R., Theuns, D. A. M. J., Szili-Torok, T., & Yap, S.-C. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1557046 · Cited by 39
“ICM should be considered in patients with suspected or certain reflex syncope presenting with frequent or severe syncopal episodes [9,10,27].”
BackgroundPathophysiology of neurally mediated syncope: Role of cardiac output and total peripheral resistance
Fu, Q., & Levine, B. D. (2014) · Autonomic Neuroscience · doi:10.1016/j.autneu.2014.07.004 · Cited by 39
“The International Study on Syncope of Unknown Etiology (ISSUE) 2 study hypothesized that spontaneous asystole should form the basis for patient selection for pacemaker therapy (Brignole et al., 2006).”
BackgroundMoya, A., Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Wieling, W., Andresen, D., Benditt, D. G., Garcia-Sacristán, J. F., Beiras, X., et al. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.07.043 · Cited by 38
Self-citationBrien, H. O., & Kenny, R. A. (2014) · European Cardiology Review · doi:10.15420/ecr.2014.9.1.28 · Cited by 49
Reflex syncope: Diagnosis and treatment
Sutton, R. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.03.007 · Cited by 38
“This was done initially in the International study of syncope of unknown etiology (ISSUE-2) [29] by implantation of ILRs in all patients.”
MethodSelf-citationCardiac Causes for Falls and Their Treatment
Cronin, H., & Kenny, R. A. (2010) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2010.07.006 · Cited by 48
Pathophysiology of reflex syncope: A review
Adkisson, W. O., & Benditt, D. G. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13266 · Cited by 49
Self-citationvan Dijk, N., Boer, M. C., Santo, T. D., Grovale, N., AERTS, A. J. J., Boersma, L. V. A., & Wieling, W. (2007) · EP Europace · doi:10.1093/europace/eum104 · Cited by 36
“During the 2-year inclusion period 442 patients were eligible for inclusion in ISSUE-2.”
BackgroundMethodSelf-citationKey challenges in the current management of syncope
Sutton, R., Brignole, M., & Benditt, D. G. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.102 · Cited by 33
Self-citationDiagnostic and therapeutic value of implantable loop recorder: A tertiary care center experience
Padmanabhan, D., Kancharla, K., El‐Harasis, M. A., Isath, A. M., Makkar, N., Noseworthy, P. A., Friedman, P. A., Cha, Y., & Kapa, S. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13533 · Cited by 35
“8%) patients over a median of 12 (1-42) months.”
BackgroundFukunaga, M., Wichterle, D., Peichl, P., Aldhoon, B., Cihak, R., & Kautzner, J. (2017) · Europace · doi:10.1093/europace/euw100 · Cited by 33
Sutton, R., de Jong, J. S. Y., Stewart, J. M., Fedorowski, A., & de Lange, F. J. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.01.029 · Cited by 35
Self-citationde Jong, J. S. Y., Blok, M. R. S., Thijs, R. D., Harms, M. P. M., Hemels, M. E. W., de Groot, J. R., van Dijk, N., & de Lange, F. J. (2020) · EP Europace · doi:10.1093/europace/euaa345 · Cited by 38
Current and Emerging Indications for Implantable Cardiac Monitors
Giada, F., Bertaglia, E., Reimers, B., Noventa, D., & Raviele, A. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03411.x · Cited by 39
Implantable loop recorders in the investigation of unexplained syncope: a state of the art review
Parry, S. W., & Matthews, I. G. (2010) · Heart · doi:10.1136/hrt.2010.193417 · Cited by 31
Diretrizes Brasileiras de Dispositivos Cardíacos Eletrônicos Implantáveis (DCEI)
Martinelli, M., Gerais, C., & Brasileira, S. (2007) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2007001800017 · Cited by 61
Efficacy of theophylline in patients affected by low adenosine syncope
Brignole, M., Solari, D., Iori, M., Bottoni, N., Guieu, R., & Deharo, J. C. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.12.016 · Cited by 29
“#5 3 5 2 1 1 20 0 0 Median (IQR) 12 (3-18) 5 (2-20) 13 (1124) 0.”
BackgroundSelf-citationBrignole, M., Sutton, R., Wieling, W., Lu, S., Erickson, M. K., Markowitz, T., Grovale, N., Ammirati, F., Benditt, D. G., & on behalf of the ISSUE 2 investigators (2007) · EP Europace · doi:10.1093/europace/eum017 · Cited by 28
Self-citationManagement of Syncope in Adults: An Update
Chen, L. Y., Benditt, D. G., & Shen, W.-K. (2008) · Mayo Clinic Proceedings · doi:10.4065/83.11.1280 · Cited by 33
Self-citationEffectiveness and Safety of Remote Monitoring of Patients With an Implantable Loop Recorder
Hernández, Y. D., Toquero‐Ramos, J., Fernández, J. M., Pérez-Pereira, E., Castro‐Urda, V., & Lozano, I. F. (2013) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.06.009 · Cited by 36
Blood pressure oscillations during tilt testing as a predictive marker of vasovagal syncope
Hausenloy, D. J., Arhi, C., Chandra, N. S., Franzén, A.-C., Meyer, A., & Sutton, R. (2009) · EP Europace · doi:10.1093/europace/eup338 · Cited by 30
Self-citationParuchuri, V., Adhaduk, M., Garikipati, N. V., Steinberg, J. S., & Mittal, S. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.01.039 · Cited by 29
PETIX, N. R., DEL ROSSO, A., FURLAN, R., GUARNACCIA, V., & ZIPOLI, A. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12235 · Cited by 27
Guía ESC 2021 sobre estimulación cardiaca y terapia de resincronización
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · Revista Española de Cardiología · doi:10.1016/j.recesp.2021.10.025 · Cited by 37
Self-citationVitale, E., Ungar, A., Maggi, R., Francese, M., Lunati, M., Colaceci, R., Rosso, A. D., Castro, A., Santini, M., Giuli, S., et al. (2010) · EP Europace · doi:10.1093/europace/euq302 · Cited by 28
Self-citationHistory of electrical therapy for the heart
Sutton, R., Fisher, J. D., Linde, C. M., & Benditt, D. G. (2007) · European Heart Journal Supplements · doi:10.1093/eurheartj/sum072 · Cited by 28
Self-citationSutton, R., Ungar, A., Sgobino, P., Russo, V., Massa, R., Melissano, D., Beiras, X., Bottoni, N., Ebert, H., Francese, M., et al. (2014) · EP Europace · doi:10.1093/europace/eut323 · Cited by 26
Self-citationArrocha, A., Klein, G. J., Benditt, D. G., Sutton, R., & Krahn, A. D. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02857.x · Cited by 24
Self-citationRuwald, M. H., & Zaręba, W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.08.007 · Cited by 23
“As many as 50% of all syncopal events in patients with no apparent heart disease present as arrhythmias when the patients have been subject to investigations with implantable loop recorder (ILR).(12,18) If the patient experiences a recurrence while monitored and no symptom–ECG correlation was evident, this allows for…”
BackgroundResultInfluentialBurkowitz, J., Merzenich, C., Grassme, K. S., & Brüggenjürgen, B. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316632628 · Cited by 25
“For the application of ICM in reflex syncope, the series of International Study of Syncope of Uncertain Etiology (ISSUE) studies more recently established the benefits of pacing therapy in patients with neutrally mediated syncope with an ICM-based diagnosis of asystole.(19,20) The ISSUE 3 study also supported the clas…”
MethodCalkins, H. G., & Zipes, D. P. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0398-6.00042-1 · Cited by 24
Huemer, M., Becker, A., Wutzler, A., Attanasio, P., Parwani, A. S., Lacour, P., Boldt, L., Pieske, B. M., Haverkamp, W., & Blaschke, F. (2018) · Cardiology Journal · doi:10.5603/cj.a2018.0008 · Cited by 24
“Cardiac arrhythmias as primary cause of syncopes are common and most of them are caused by bradyarrhythmic events [10].”
Background
Metadata
- Authors
- Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P.
- Affiliations
- Presidio Ospedaliero (IT)
- Royal Brompton & Harefield NHS Foundation Trust (GB)
- Santa Maria Nuova Hospital (IT)
- University of Amsterdam (NL)
- Vivantes Klinikum (DE)
- University Hospital of Heraklion (GR)
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-03-28
- Volume
- 27
- Issue
- 9
- Pages
- 1085-1092
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2143491599
- Cited by
- 376
- References
- 22
- Citations by year
- 2026: 9 · 2025: 5 · 2024: 8 · 2023: 7 · 2022: 10 · 2021: 15 · 2020: 10 · 2019: 11 · 2018: 17 · 2017: 25 · 2016: 20 · 2015: 20 · 2014: 29 · 2013: 37 · 2012: 22
- FWCI
- 26.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- HighWire Press Open Archive (submittedVersion)
- Pure Amsterdam UMC (submittedVersion)
- Funders
- Medtronic
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- neurally mediated syncope, implantable loop recorder, syncope recurrence, pacemaker implantation, catheter ablation, implantable cardioverter-defibrillator, specific therapy
- MeSH terms
- Adult, Aged, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Cardiac Pacing, Artificial, Electrodes, Implanted, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Recurrence, Risk Factors, Catheter Ablation, Syncope, Vasovagal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.