Long-term follow-up of primary prophylactic implantable cardioverter-defibrillator therapy in Brugada syndrome
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: To analyse the follow-up data of implantable cardioverter-defibrillator (ICD) therapy in Brugada syndrome (BS). METHODS AND RESULTS: We conducted a retrospective, single centre study of 47 patients (mean age: 44.5 +/- 15 years) with BS, who underwent primary prophylactic ICD implantation. All patients had baseline spontaneous (23 patients) or drug-induced (24 patients) coved type I ECG pattern. All patients were judged to be at high risk because of syncope (26 patients) and/or a positive family history of sudden death (26 patients). During a median follow-up of 47.5 months, seven patients had appropriate shocks. The presence of spontaneous type I ECG and non-sustained ventricular tachyarrhythmia in the ICD datalog suggested a trend towards shorter appropriate shock-free survival by Kaplan-Meier analysis (P = 0.037 and P = 0.012, respectively). Seventeen patients received inappropriate shocks (IS); eight patients for sinus tachycardia; six patients for new onset atrial arrhythmias; and five patients for noise oversensing. In multivariable Cox-regression analysis, new onset atrial fibrillation (AF) and less than 50 years of age were independent predictors of significantly shorter IS-free survival (P = 0.04 and P = 0.036, respectively). CONCLUSION: In high-risk patients with BS, primary prophylactic ICD therapy is an effective treatment. In this, young and otherwise healthy patient population, the IS rate is high.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Cited by
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Priori, S. G., Wilde, A. A., Horie, M., Cho, Y., Behr, E. R., Berul, C., Blom, N., Brugada, J., Chiang, C.-E., Huikuri, H., et al. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.05.014 · Cited by 1,942
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,489
Probst, V., Veltmann, C., Eckardt, L., Meregalli, P. G., Gaita, F., Tan, H. L., Babuty, D., Sacher, F., Giustetto, C., Schulze-Bahr, E., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.887026 · Cited by 847
“Until now, the only available treatment that has proven to prevent SCD in BrS patients is ICD implantation.(5,28) This intervention represents an attractive option to protect patients against SCD.”
BackgroundTracy, C. M., Epstein, A. E., Darbar, D., DiMarco, J. P., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P. E., Link, M. S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 732
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 552
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.004 · Cited by 478
Sacher, F., Probst, V., Maury, P., Babuty, D., Mansourati, J., Komatsu, Y., Marquie, C., Rosa, A., Diallo, A., Cassagneau, R., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.001941 · Cited by 448
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000499 · Cited by 438
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000498 · Cited by 407
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.003 · Cited by 327
Sacher, F., Probst, V., Iesaka, Y., Jacon, P., Laborderie, J., Mizon-Gérard, F., Mabo, P., Reuter, S., Lamaison, D., Takahashi, Y., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.628537 · Cited by 293
Olde Nordkamp, L. R. A., Postema, P. G., Knops, R. E., van Dijk, N., Limpens, J., Wilde, A. A. M., & de Groot, J. R. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.09.010 · Cited by 267
Delise, P., Allocca, G., Marras, E., Giustetto, C., Gaita, F., Sciarra, L., Calo, L., Proclemer, A., Marziali, M., Rebellato, L., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq381 · Cited by 221
“In the current literature, the predictive value of EPS is controversial.(23,24) Indeed, while some authors(13,14) report a high prognostic significance of EPS, others deny its usefulness.”
A score model to predict risk of events in patients with Brugada Syndrome
Sieira, J., Conte, G., Ciconte, G., Chierchia, G.-B., Casado-Arroyo, R., Baltogiannis, G., Di Giovanni, G., Saitoh, Y., Juliá, J., Mugnai, G., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx119 · Cited by 215
Self-citationImplantable Cardioverter-Defibrillator Therapy in Brugada Syndrome
Conte, G., Sieira, J., Ciconte, G., de Asmundis, C., Chierchia, G.-B., Baltogiannis, G., Di Giovanni, G., La Meir, M., Wellens, F., Czapla, J., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.12.031 · Cited by 199
“9%) conducted in patients undergoing ICD implantation for prophylactic purposes only (6).”
BackgroundResultInfluentialSelf-citationShen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.002 · Cited by 155
“III: No Benefit B-NR ICD implantation is not recommended in patients with Brugada ECG pattern and reflex-mediated syncope in the absence of other risk factors.(205,206) 4.”
BackgroundOlde Nordkamp, L. R. A., Vink, A. S., Wilde, A. A. M., de Lange, F. J., de Jong, J. S. S. G., Wieling, W., van Dijk, N., & Tan, H. L. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2014.10.014 · Cited by 80
“Prevalence of nonarrhythmic syncope The high prevalence of syncope in our study is in line with previous studies of BrS patients.(10,11) However, our study confirms data from other smaller studies that almost half of patients with syncope have suffered from suspected nonarrhythmic syncope, which also explains the rela…”
ResultSyncope in Children and Adolescents
Kanjwal, K., & Calkins, H. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.008 · Cited by 52
Medeiros, P., Santos, M., Arantes, C., Pereira, V. H., & Rocha, S. (2023) · Heart & Lung · doi:10.1016/j.hrtlng.2023.02.012 · Cited by 9
Metadata
- Authors
- Sarkozy, A., Boussy, T., Kourgiannides, G., Chierchia, G.-B., Richter, S., De Potter, T., Geelen, P., Wellens, F., Dingena Spreeuwenberg, M., & Brugada, P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-01-11
- Volume
- 28
- Issue
- 3
- Pages
- 334-344
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2149671207
- Cited by
- 231
- References
- 1
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.