Strain rate imaging for functional quantification of the left atrium: atrial deformation predicts the maintenance of sinus rhythm after catheter ablation of atrial fibrillation
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
AIMS: The aim of the study was to investigate the atrial myocardial deformation properties using ultrasound strain rate (SR) imaging in patients after catheter ablation of atrial fibrillation (AF) and to compare its prognostic value in maintaining sinus rhythm. METHODS AND RESULTS: A total of 118 patients with AF (74 paroxysmal AF, 44 persistent AF) underwent transthoracic echocardiography with Doppler-derived SR examinations before and after ablation as well as during 3 months of follow-up (FU). Peak SR and strain (S) were measured at each left atrium (LA) segment (septal, lateral, anterior, inferior) during systole (LAs) and at early (LAe) and late diastole (LAa). Clinical and echocardiographic parameters of patients with maintained sinus rhythm during FU were compared with those with recurrent AF and controls (n = 25 patients). Of 118 patients 82 (69%) showed stable sinus rhythm during FU. Atrial myocardial properties after catheter ablation differed significantly in patients with paroxysmal AF (SR-LAs 2.5 s(-1), S-LAs 30%, SR-LAa -2.2 s(-1)) from patients with persistent AF (SR-LAs 2.3 s(-1), S-LAs 25%, SR-LAa -1.9 s(-1)) and controls (SR-LAs 4.1 s(-1), S-LAs 88%, SR-LAa -2.9 s(-1)) (P = 0.011). Best individual predictors of sinus rhythm maintenance were cut-off values of >2.25 s(-1) for septal and inferior SR-LAs and of >19.5% for inferior S-LAs (P < 0.001). LA deformation properties increased in patients with maintained sinus rhythm during FU in contrast to patients with recurrent AF (P = 0.001). CONCLUSION: SR imaging enables the quantitative assessment of the LA function and can be considered as a potential marker of atrial reverse remodelling. Patients with higher atrial S and SR after catheter ablation appear to have a greater likelihood of maintenance of sinus rhythm. This may have further implications for the anticoagulation regime and the risk of cardioembolic complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388 · cited 2×
“Atrial fibrillation (AF) is the most common cardiac arrhythmia.(1,2) It”
BackgroundStatistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220 · cited 1×
“For interobserver variability, Bland–Altman plots and 95% limits of the equal-tailed Jeffrey’s prior interval were used by analysing 20 patients by two independent investigators.(11) For the assessment of intraobserver variability, 11 randomly chosen patients were analysed by the same investigator twice.”
MethodSuppression of paroxysmal atrial tachyarrhythmias—results of the SOPAT trial
PATTEN, M., MAAS, R., BAUER, P., LUDERITZ, B., SONNTAG, F., DLUZNIEWSKI, M., HATALA, R., OPOLSKI, G., MULLER, H., & MEINERTZ, T. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.014 · Cited by 157
Cited by
Hoit, B. D. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.055 · Cited by 980
Goette, A., Kalman, J. M., Aguinaga, L., Akar, J., Cabrera, J. A., Chen, S. A., Chugh, S. S., Corradi, D., D’Avila, A., Dobrev, D., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2016.05.028 · Cited by 771
Goette, A., Kalman, J. M., Aguinaga, L., Akar, J., Cabrera, J. A., Chen, S. A., Chugh, S. S., Corradi, D., D'Avila, A., Dobrev, D., et al. (2016) · Europace · doi:10.1093/europace/euw161 · Cited by 762
Kuppahally, S. S., Akoum, N., Burgon, N. S., Badger, T. J., Kholmovski, E. G., Vijayakumar, S., Rao, S. N., Blauer, J., Fish, E. N., DiBella, E. V. R., et al. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.865683 · Cited by 709
Left Atrial Structure and Function, and Left Ventricular Diastolic Dysfunction
Thomas, L., Marwick, T. H., Popescu, B. A., Donal, E., & Badano, L. P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.059 · Cited by 653
Left atrial function: physiology, assessment, and clinical implications
Blume, G. G., Mcleod, C. J., Barnes, M. E., Seward, J. B., Pellikka, P. A., Bastiansen, P. M., & Tsang, T. S. M. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq175 · Cited by 518
Left Atrial Function in Diastolic Heart Failure
Kurt, M., Wang, J., Torre-Amione, G., & Nagueh, S. F. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.813071 · Cited by 502
Clinical Utility of Multimodality LA Imaging
To, A. C. Y., Flamm, S. D., Marwick, T. H., & Klein, A. L. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2011.02.018 · Cited by 236
Left Atrial Strain Predicts Reverse Remodeling After Catheter Ablation for Atrial Fibrillation
Tops, L. F., Delgado, V., Bertini, M., Marsan, N. A., Den Uijl, D. W., Trines, S. A. I. P., Zeppenfeld, K., Holman, E., Schalij, M. J., & Bax, J. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.063 · Cited by 223
“hythm during 3 months of follow-up (8).”
BackgroundLeft atrial function: evaluation by strain analysis
Gan, G. C. H., Ferkh, A., Boyd, A., & Thomas, L. (2018) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.06.08 · Cited by 206
Structure and Function of the Left Atrium and Left Atrial Appendage
Delgado, V., Di Biase, L., Leung, M., Romero, J., Tops, L. F., Casadei, B., Marrouche, N., & Bax, J. J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.063 · Cited by 203
“In patients undergoing catheter ablation for AF, LA reservoir function is predictive of maintaining sinus rhythm (17), and is an independent predictor of LA reverse remodeling (18).”
BackgroundHabibi, M., Lima, J. A. C., Khurram, I. M., Zimmerman, S. L., Zipunnikov, V., Fukumoto, K., Spragg, D., Ashikaga, H., Rickard, J., Marine, J. E., et al. (2015) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.114.002769 · Cited by 194
“In a study of 74 paroxysmal and 44 patients with persistent AF, those with persistent AF had lower absolute values for both strain and strain rate measurements and also lower total LA emptying fraction.(21) Kuppahally et al(7) also reported lower LA midseptal strain and SR-s, and lower midlateral strain but not SR-s i…”
Result
Metadata
- Authors
- Schneider, C., Malisius, R., Krause, K., Lampe, F., Bahlmann, E., Boczor, S., Antz, M., Ernst, S., & Kuck, K.-H.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-01-18
- Volume
- 29
- Issue
- 11
- Pages
- 1397-1409
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2164376203
- Cited by
- 189
- References
- 6
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.