Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 277

The DOI matches its Crossref record.

Detection of acute changes in circulating troponin in the setting of transient stress test-induced myocardial ischaemia using an ultrasensitive assay: results from TIMI 35

Open access
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Jarolim, P., Braunwald, E.·2008·European Heart Journal

Abstract

AIMS: To determine whether an ultrasensitive assay can permit quantification of changes in circulating cardiac troponin (Tn) in the setting of stress test-induced myocardial ischaemia. METHODS AND RESULTS: Blood samples were obtained before, immediately after, and 2 and 4 h after stress testing with nuclear perfusion imaging in 120 patients. Troponin was measured using commercial assays as well as with a novel, ultrasensitive cardiac TnI assay with a limit of detection of 0.2 pg/mL. Using the ultrasensitive assay, TnI was detectable in all patients before stress testing (median 4.4 pg/mL, interquartile range 3.1-8.6 pg/mL). By 4 h, troponin levels were unchanged in patients without ischaemia, whereas circulating levels had increased by a median of 1.4 pg/mL (24% increase) in patients with mild ischaemia (P = 0.002) and by 2.1 pg/mL (40% increase) in patients with moderate-to-severe ischaemia (P = 0.0006). In contrast, changes in troponin levels across patients in different ischaemic categories were indistinguishable using commercial troponin assays. When added to clinical factors, a >1.3 pg/mL increase in TnI using the ultrasensitive assay was an independent predictor of ischaemia (odds ratio 3.54, P = 0.007). CONCLUSION: Transient stress test-induced myocardial ischaemia is associated with a quantifiable increase in circulating troponin that is detectable with a novel, ultrasensitive TnI assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehn504

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 277

Metadata

Authors
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Jarolim, P., & Braunwald, E.
Venue
European Heart Journal
Published
2008-05-21
Volume
30
Issue
2
Pages
162-169
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2165025270
Cited by
277
References
0
FWCI
16.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of acute changes in circulating troponin in the setting of transient stress test-induced myocardial ischaemia using an ultrasensitive assay: results from TIMI 35. https://app.cochat.ai/papers/10.1093/eurheartj/ehn504
The paper
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Jarolim, P., & Braunwald, E. (2008). Detection of acute changes in circulating troponin in the setting of transient stress test-induced myocardial ischaemia using an ultrasensitive assay: results from TIMI 35. European Heart Journal. https://doi.org/10.1093/eurheartj/ehn504

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.