Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
AIMS: Multidetector computed tomography coronary angiography (CTA) has emerged as a feasible imaging modality for non-invasive assessment of coronary artery disease (CAD). Recently, 320-row CTA systems were introduced, with 16 cm anatomical coverage, allowing image acquisition of the entire heart within a single heart beat. The aim of the present study was to assess the diagnostic accuracy of 320-row CTA in patients with known or suspected CAD. METHODS AND RESULTS: A total of 64 patients (34 male, mean age 61 +/- 16 years) underwent CTA and invasive coronary angiography. All CTA scans were evaluated for the presence of obstructive coronary stenosis by a blinded expert, and results were compared with quantitative coronary angiography. Four patients were excluded from initial analysis due to non-diagnostic image quality. Sensitivity, specificity, and positive and negative predictive values to detect > or =50% luminal narrowing on a patient basis were 100, 88, 92, and 100%, respectively. Moreover, sensitivity, specificity, and positive and negative predictive values to detect > or =70% luminal narrowing on a patient basis were 94, 95, 88, and 98%, respectively. With inclusion of non-diagnostic imaging studies, sensitivity, specificity, and positive and negative predictive values to detect > or =50% luminal narrowing on a patient basis were 100, 81, 88, and 100%, respectively. CONCLUSION: The current study shows that 320-row CTA allows accurate non-invasive assessment of significant CAD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256 · cited 1×
“Coronary anatomy was assessed in a standardized manner by dividing the coronary artery tree into 17 segments according to a modified American Heart Association classification.(8) Each segment was determined interpretable or uninterpretable, and evaluated for the presence of 50 and 70% stenosis.”
MethodBudoff, M. J., Dowe, D., Jollis, J. G., Gitter, M., Sutherland, J., Halamert, E., Scherer, M., Bellinger, R., Martin, A., Benton, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.031 · Cited by 2,125 · cited 1×
“These findings are in line with previously published data using a 70% stenosis cut-off in the evaluation of CAD using 64-row CTA.(12)”
ResultDiagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Self-citationEinstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410 · cited 1×
“Concerns have been raised about radiation dose, especially with respect to the long-term sequelae in younger people and women of childbearing age.(24) Accordingly, careful patient selection is warranted, and conservative imaging protocols, with respect to radiation dose, should be aimed for.”
BackgroundBenefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
Meijboom, W. B., Meijs, M. F. L., Schuijf, J. D., Cramer, M. J., Mollet, N. R., van Mieghem, C. A. G., Nieman, K., van Werkhoven, J. M., Pundziute, G., Weustink, A. C., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.058 · Cited by 1,239 · cited 1×
“These results are in line with previous published data on the performance of 64-row CTA.(9) –12”
ResultSelf-citationSCCT guidelines for the interpretation and reporting of coronary computed tomographic angiography
Raff, G. L., Chair, Abidov, A., Achenbach, S., Berman, D. S., Boxt, L. M., Budoff, M. J., Cheng, V., DeFrance, T., Hellinger, J. C., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.01.001 · Cited by 773 · cited 1×
“Subsequently, axial slices were visually examined for the presence of significant narrowing by determining the presence of 50 and 70% reduction of luminal diameter as recommended by the SCCT guidelines for the interpretation and reporting of CTA.(7) Computed tomography coronary angiography analysis was assisted by cur…”
MethodInitial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm613 · Cited by 530 · cited 1×
“maximal dose reduction by using tube voltages with a maximum of 100 or 120 kV as well as performing image acquisition during a minimal phase window of only 75% of the cardiac cycle.(20,21) Other technical advances, such as adaptive collimation and highpitch spiral acquisition, may also allow significant radiation redu…”
Mowatt, G., Cook, J. A., Hillis, G. S., Walker, S., Fraser, C., Jia, X., & Waugh, N. (2008) · Heart · doi:10.1136/hrt.2008.145292 · Cited by 484
Achenbach, S. S., Ropers, D., Kuettner, A., Flohr, T. G., Ohnesorge, B. M., Bruder, H., Theessen, H., Karakaya, M., Daniel, W. G., Bautz, W. A., et al. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.12.017 · Cited by 435 · cited 1×
“Similarly, dual-source systems, with even superior temporal resolution (83 ms), allow limited craniocaudal coverage per rotation.(15) In contrast, 320-row CTA allows volumetric data acquisition with full cardiac coverage in a single rotation, eliminating the problem of stair-step artefacts associated with helical and…”
BackgroundManaging patient dose in Multi-Detector Computed Tomography (MDCT)
Valentin, J. (2007) · Elsevier eBooks · Cited by 352
High-pitch spiral acquisition: A new scan mode for coronary CT angiography
Achenbach, S., Marwan, M., Schepis, T., Pflederer, T., Bruder, H., Allmendinger, T., Petersilka, M., Anders, K., Lell, M., Kuettner, A., et al. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.02.008 · Cited by 258
Raff, G. L. (2009) · JAMA · doi:10.1001/jama.2009.814 · Cited by 233
Maruyama, T., Takada, M., Hasuike, T., Yoshikawa, A., Namimatsu, E., & Yoshizumi, T. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.048 · Cited by 175 · cited 1×
“Subsequently, prospective ECG triggering became available, allowing data acquisition during a narrow pre-defined portion of the R-R interval (usually enddiastolic phase when the heart is relatively motion-free), resulting in a substantial reduction in radiation dose.(17) Importantly, volumetric data acquisition used b…”
MethodSun, Z., & Jiang, W. J. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.009 · Cited by 138 · cited 11×
“In addition, CTA was performed in patients referred for invasive coronary angiography, creating a selection bias of patients with a relatively high prevalence of significant CAD.”
MethodInfluentialHerzog, B. A., Husmann, L., Burkhard, N., Gaemperli, O., Valenta, I., Tatsugami, F., Wyss, C. A., Landmesser, U., & Kaufmann, P. A. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn485 · Cited by 128 · cited 1×
“maximal dose reduction by using tube voltages with a maximum of 100 or 120 kV as well as performing image acquisition during a minimal phase window of only 75% of the cardiac cycle.(20,21) Other technical advances, such as adaptive collimation and highpitch spiral acquisition, may also allow significant radiation redu…”
Initial experience with a chest pain protocol using 320-slice volume MDCT
Hein, P. A., Romano, V. C., Lembcke, A. E., May, J., & Rogalla, P. (2009) · European Radiology · doi:10.1007/s00330-008-1255-8 · Cited by 78 · cited 1×
“In addition, improved temporal resolution and scan time result in an overall reduction of cardiac motion artefacts and eliminate the problem of stair-step artefacts, observed during step-and-shoot acquisition techniques and helical imaging.(2) –5”
BackgroundRybicki, F. J., Melchionna, S., Mitsouras, D., Coskun, A. U., Whitmore, A. G., Steigner, M. L., Nallamshetty, L., Welt, F. G. P., Bernaschi, M., Borkin, M. A., et al. (2009) · International journal of cardiac imaging · doi:10.1007/s10554-008-9418-x · Cited by 75
What are the potential advantages and disadvantages of volumetric CT scanning?
Vörös, S. (2009) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2008.12.010 · Cited by 37
A modified rabbit model of reperfused myocardial infarction for cardiac MR imaging research
Feng, Y., Xie, Y., Wang, H., Chen, F., Ye, Y., Jin, L., Marchal, G., & Ni, Y. (2008) · International journal of cardiac imaging · doi:10.1007/s10554-008-9393-2 · Cited by 29
Cited by
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Boogers, M. J., Broersen, A., van Velzen, J. E., de Graaf, F. R., El-Naggar, H. M., Kitslaar, P. H., Dijkstra, J., Delgado, V., Boersma, E., de Roos, A., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr465 · Cited by 233
“The non-enhanced and contrast-enhanced scans were performed as previously described.(6,12) Reconstructed images were transferred to a remote dedicated workstation with post-processing software (Vitrea FX 1.”
MethodSelf-citationIsrael, O., Pellet, O., Biassoni, L., De Palma, D., Estrada-Lobato, E., Gnanasegaran, G., Kuwert, T., la Fougère, C., Mariani, G., Massalha, S., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04404-6 · Cited by 225
Coronary CT angiography: current status and continuing challenges
Sun, Z., Choo, G. H., & Ng, K. H. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15296170 · Cited by 189
“50% coronary stenosis on a patient-based analysis [39].”
Schuetz, G. M., Schlattmann, P., & Dewey, M. (2012) · BMJ · doi:10.1136/bmj.e6717 · Cited by 176
Metadata
- Authors
- de Graaf, F. R., Schuijf, J. D., van Velzen, J. E., Kroft, L. J., de Roos, A., Reiber, J. H. C., Boersma, E., Schalij, M. J., Spano, F., Jukema, J. W., van der Wall, E. E., & Bax, J. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-01-04
- Volume
- 31
- Issue
- 15
- Pages
- 1908-1915
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2097925321
- Cited by
- 200
- References
- 21
- FWCI
- 20.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.