Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial

Conraads, Viviane M., Tavazzi, Luigi, Santini, Massimo, Oliva, Fabrizio, Gerritse, Bart, Yu, Cheuk-Man, Cowie, Martin R.·2011·European Heart Journal

Abstract

AIMS: Early recognition of impending decompensation and timely intervention may prevent heart failure (HF) hospitalization. We investigated the performance of OptiVol® intrathoracic fluid monitoring for the prediction of HF events in chronic HF patients newly implanted with a device (implantable cardioverter-defibrillator with or without cardiac resynchronization therapy). METHODS AND RESULTS: SENSE-HF was a prospective, multi-centre study that enrolled 501 patients. Phase I (double blinded, 6 months) determined the sensitivity and positive predictive value (PPV) of the OptiVol data in predicting HF hospitalizations. Of 58 adjudicated HF hospitalizations that occurred during the first 6 months in Phase I, 12 were predicted by OptiVol (sensitivity = 20.7%). Sensitivity appeared to be dynamic in nature and at the end of Phase I, had increased to 42.1%. With 253 OptiVol detections, PPV for Phase I was 4.7%. Phase II/III (unblinded, 18 months) determined the PPV of the first OptiVol Patient Alert for detection of worsening HF status with signs and/or symptoms of pulmonary congestion. A total of 233 patients noted such an OptiVol alert and for 210, HF status was evaluated within 30 days. Heart failure status had worsened for 80 patients (PPV = 38.1%). CONCLUSIONS: An intrathoracic impedance-derived fluid index had low sensitivity and PPV in the early period after implantation of a device in chronic HF patients. Sensitivity improved within the first 6 months after implant. Further studies are needed to assess the place of this monitoring technology in the clinical management of patients with HF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehr050

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 298

Metadata

Authors
Conraads, V. M., Tavazzi, L., Santini, M., Oliva, F., Gerritse, B., Yu, C.-M., & Cowie, M. R.
Venue
European Heart Journal
Published
2011-02-28
Volume
32
Issue
18
Pages
2266-2273
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2140482095
Cited by
298
References
1
FWCI
19.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial. https://app.cochat.ai/papers/10.1093/eurheartj/ehr050
The paper
Conraads, V. M., Tavazzi, L., Santini, M., Oliva, F., Gerritse, B., Yu, C.-M., & Cowie, M. R. (2011). Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial. European Heart Journal. https://doi.org/10.1093/eurheartj/ehr050

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.