Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
AIMS: Early recognition of impending decompensation and timely intervention may prevent heart failure (HF) hospitalization. We investigated the performance of OptiVol® intrathoracic fluid monitoring for the prediction of HF events in chronic HF patients newly implanted with a device (implantable cardioverter-defibrillator with or without cardiac resynchronization therapy). METHODS AND RESULTS: SENSE-HF was a prospective, multi-centre study that enrolled 501 patients. Phase I (double blinded, 6 months) determined the sensitivity and positive predictive value (PPV) of the OptiVol data in predicting HF hospitalizations. Of 58 adjudicated HF hospitalizations that occurred during the first 6 months in Phase I, 12 were predicted by OptiVol (sensitivity = 20.7%). Sensitivity appeared to be dynamic in nature and at the end of Phase I, had increased to 42.1%. With 253 OptiVol detections, PPV for Phase I was 4.7%. Phase II/III (unblinded, 18 months) determined the PPV of the first OptiVol Patient Alert for detection of worsening HF status with signs and/or symptoms of pulmonary congestion. A total of 233 patients noted such an OptiVol alert and for 210, HF status was evaluated within 30 days. Heart failure status had worsened for 80 patients (PPV = 38.1%). CONCLUSIONS: An intrathoracic impedance-derived fluid index had low sensitivity and PPV in the early period after implantation of a device in chronic HF patients. Sensitivity improved within the first 6 months after implant. Further studies are needed to assess the place of this monitoring technology in the clinical management of patients with HF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term trends in the incidence of and survival with heart failure
Levy, D., Kenchaiah, S., Larson, M. G., Benjamin, E. J., Kupka, M. J., Ho, K. K. L., Murabito, J. M., & Vasan, R. S. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa020265 · Cited by 2,152 · cited 1×
“Accruing evidence shows that episodes of heart failure (HF) decompensation unfavourably affect prognosis.(1)”
BackgroundYu, C.-M., Wang, L., Chau, E., Chan, R. H.-W., Kong, S.-L., Tang, M.-O., Christensen, J., Stadler, R. W., & Lau, C.-P. (2005) · Circulation · doi:10.1161/circulationaha.104.492207 · Cited by 711
Self-citationCleland, J. G. F., Louis, A. A., Rigby, A. S., Janssens, U., & Balk, A. H. M. M. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.050 · Cited by 700 · cited 1×
“Different approaches, such as monitoring of weight, blood pressure, heart rate, and rhythm, have been tested to predict HF-related hospital admissions.(3,5) Information obtained from a totally implantable continuous haemodynamic monitor in the COMPASS-HF trial led to a non-significant 21% lower rate of HF-related even…”
Zile, M. R., Bennett, T. D., St. John Sutton, M., Cho, Y. K., Adamson, P. B., Aaron, M. F., Aranda, J. M., Abraham, W. T., Smart, F. W., Stevenson, L. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.783910 · Cited by 571
Bourge, R. C., Abraham, W. T., Adamson, P. B., Aaron, M. F., Aranda, J. M., Magalski, A., Zile, M. R., Smith, A. L., Smart, F. W., O’Shaughnessy, M. A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.061 · Cited by 550
Congestion in Acute Heart Failure Syndromes: An Essential Target of Evaluation and Treatment
Gheorghiade, M., Filippatos, G., De Luca, L., & Burnett, J. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2006.09.011 · Cited by 426
Whellan, D. J., Ousdigian, K. T., Al-Khatib, S. M., Pu, W., Sarkar, S., Porter, C. B., Pavri, B. B., & O'Connor, C. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.089 · Cited by 374
Preventing Osteoporosis-Related Fractures: An Overview
Gass, M., & Dawson-Hughes, B. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.12.017 · Cited by 342
Adamson, P. B., Smith, A. L., Abraham, W. T., Kleckner, K. J., Stadler, R. W., Shih, A., & Rhodes, M. M. (2004) · Circulation · doi:10.1161/01.cir.0000139841.42454.78 · Cited by 309
The pathophysiology of acute heart failure—Is it all about fluid accumulation?
Cotter, G., Felker, G. M., Adams, K. F., Milo-Cotter, O., & O'Connor, C. M. (2008) · American Heart Journal · doi:10.1016/j.ahj.2006.02.038 · Cited by 201
Vollmann, D., Nägele, H., Schauerte, P., Wiegand, U., Butter, C., Zanotto, G., Quesada, A., Guthmann, A., Hill, M. R. S., & Lamp, B. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl506 · Cited by 180
Lewin, J., Ledwidge, M., O’Loughlin, C., McNally, C., & McDonald, K. (2005) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2005.06.003 · Cited by 177
Magalski, A., Adamson, P., Gadler, F., Böehm, M., Steinhaus, D., Reynolds, D., Vlach, K., Linde, C., Cremers, B., Sparks, B., et al. (2002) · Journal of Cardiac Failure · doi:10.1054/jcaf.2002.32373 · Cited by 175
Zhang, J., Goode, K. M., Cuddihy, P. E., & Cleland, J. G. F. (2009) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp033 · Cited by 156
Catanzariti, D., Lunati, M., Landolina, M., Zanotto, G., LONARDI, G., Iacopino, S., Oliva, F. G., Perego, G. B., VARBARO, A., Denaro, A., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02245.x · Cited by 130
Self-citationSmall, R. S., Wickemeyer, W. J., Germany, R. E., Hoppe, B. L., Andrulli, J., Brady, P. A., Labeau, M., Koehler, J. L., Sarkar, S., Hettrick, D. A., et al. (2009) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2009.01.012 · Cited by 115
Fundamentals of Intrathoracic Impedance Monitoring in Heart Failure
Wang, L. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.02.009 · Cited by 110
Perego, G. B., Landolina, M., Vergara, G., Lunati, M., Zanotto, G., Pappone, A., LONARDI, G., Speca, G., Iacopino, S., VARBARO, A., et al. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9303-5 · Cited by 61
Braunschweig, F., Ford, I., Conraads, V., Cowie, M. R., Jondeau, G., Kautzner, J., Lunati, M., Aguilera, R. M., Yu, C. M., Marijianowski, M., et al. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.06.016 · Cited by 60
Self-citationBraunschweig, F., Mortensen, P. T., Gras, D., Reiser, W., Lawo, T., Mansour, H., Søgaard, P., Stegemann, B., Bruns, H.-J., & Linde, C. M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.12.069 · Cited by 60
Ambulatory Monitoring of Congestive Heart Failure by Multiple Bioelectric Impedance Vectors
Khoury, D. S., Naware, M., Siou, J., Blomqvist, A., Mathuria, N. S., Wang, J., Shih, H.-T., Nagueh, S. F., & Panescu, D. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.018 · Cited by 39
Burri, H., Quesada, A., Ricci, R. P., Boriani, G., Davinelli, M., Favale, S., Da Costa, A., Kautzner, J., Moser, R., Navarro, X., et al. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.04.005 · Cited by 36
Self-citationCowie, M., Conraads, V. M., Tavazzi, L., & Yu, C. (2009) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2008.12.004 · Cited by 22
Self-citationMaines, M., Landolina, M., Lunati, M., LONARDI, G., Pappone, A., Proclemer, A., Zanotto, G., Santini, M., VARBARO, A., Vimercati, M., et al. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02579.x · Cited by 19
Self-citation
Cited by
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
Self-citationDaubert, J.-C., Saxon, L., Adamson, P. B., Auricchio, A., Berger, R. D., Beshai, J. F., Breithard, O., Brignole, M., Cleland, J., DeLurgio, D. B., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.07.025 · Cited by 467
van Veldhuisen, D. J., Braunschweig, F., Conraads, V., Ford, I., Cowie, M. R., Jondeau, G., Kautzner, J., Muñoz Aguilera, R., Lunati, M., Yu, C. M., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.043042 · Cited by 444
Self-citationA Multisensor Algorithm Predicts Heart Failure Events in Patients With Implanted Devices
Boehmer, J. P., Hariharan, R., Devecchi, F. G., Smith, A. L., Molon, G., Capucci, A., An, Q., Averina, V., Stolen, C. M., Thakur, P. H., et al. (2017) · JACC: Heart Failure · doi:10.1016/j.jchf.2016.12.011 · Cited by 393
Metadata
- Authors
- Conraads, V. M., Tavazzi, L., Santini, M., Oliva, F., Gerritse, B., Yu, C.-M., & Cowie, M. R.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-02-28
- Volume
- 32
- Issue
- 18
- Pages
- 2266-2273
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2140482095
- Cited by
- 298
- References
- 24
- FWCI
- 19.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.