Lower risk of stent thrombosis and restenosis with unrestricted use of ‘new-generation’ drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR)
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
AIMS: To compare the long-term outcome after percutaneous coronary intervention with 'new-generation' drug-eluting stents (n-DES) to 'older generation' DES (o-DES), and bare-metal stents (BMS) in a real-world population. METHODS AND RESULTS: We evaluated 94 384 consecutive stent implantations (BMS, n = 64 631; o-DES, n = 19 202; n-DES, n = 10 551) in Sweden from November 2006 to October 2010. All cases of definite stent thrombosis (ST) and restenosis were documented in the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Older generation DES were classified as: Cypher and Cypher Select (Cordis Corporation, Miami, FL, USA), Taxus Express and Taxus Liberté (Boston Scientific Corporation), and Endeavor (Medtronic Inc.) and n-DES as: Endeavor Resolute (Medtronic Inc.), XienceV, Xience Prime (Abbott Laboratories) and Promus, Promus Element (Boston Scientific Corporation). The Cox regression analyses unadjusted and adjusted for clinical and angiographic covariates showed a statistically significant lower risk of restenosis in n-DES compared with BMS [adjusted hazard ratio (HR) 0.29; 95% confidence interval (CI): 0.25-0.33] and o-DES (HR 0.62; 95% CI: 0.53-0.72). A lower risk of definite ST was found in n-DES compared with BMS (HR 0.38; 95% CI: 0.28-0.52) and o-DES (HR, 0.57; 95% CI: 0.41-0.79). The risk of death was significantly lower in n-DES compared with o-DES (adjusted HR: 0.77; 95% CI: 0.63-0.95) and BMS (adjusted HR: 0.55; 95% CI: 0.46-0.67). CONCLUSION: Percutaneous coronary intervention with n-DES is associated with a 38% lower risk of clinically meaningful restenosis, a 43% lower risk of definite ST, and a 23% lower risk of death compared with o-DES in this observational study from a large real-world population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Finn, A. V., Joner, M., Nakazawa, G., Kolodgie, F., Newell, J., John, M. C., Gold, H. K., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.107.693739 · Cited by 1,277
Long-Term Outcomes with Drug-Eluting Stents versus Bare-Metal Stents in Sweden
Lagerqvist, B., James, S. K., Stenestrand, U., Lindbäck, J., Nilsson, T., & Wallentin, L. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067722 · Cited by 1,197
Self-citationAnalysis of 14 Trials Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Kastrati, A., Mehilli, J., Pache, J., Kaiser, C., Valgimigli, M., Kelbæk, H., Menichelli, M., Sabaté, M., Suttorp, M. J., Baumgart, D., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067484 · Cited by 1,006
Everolimus-Eluting versus Paclitaxel-Eluting Stents in Coronary Artery Disease
Stone, G. W., Rizvi, A., Newman, W., Mastali, K., Wang, J. C., Caputo, R., Doostzadeh, J., Cao, S., Simonton, C. A., Sudhir, K., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0910496 · Cited by 902
A Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Spaulding, C., Daemen, J., Boersma, E., Cutlip, D. E., & Serruys, P. W. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066633 · Cited by 704
Windecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
Endothelial Cell Recovery Between Comparator Polymer-Based Drug-Eluting Stents
Joner, M., Nakazawa, G., Finn, A. V., Quee, S. C., Coleman, L., Acampado, E., Wilson, P. S., Skorija, K., Cheng, Q., Xu, X., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.030 · Cited by 641
Nakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611
Stone, G. W. (2008) · JAMA · doi:10.1001/jama.299.16.1903 · Cited by 582
Kirtane, A. J., Gupta, A., Iyengar, S., Moses, J. W., Leon, M. B., Applegate, R., Brodie, B., Hannan, E., Harjai, K., Jensen, L. O., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.826479 · Cited by 577
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Incidence and Correlates of Drug-Eluting Stent Thrombosis in Routine Clinical Practice
Wenaweser, P., Daemen, J., Zwahlen, M., van Domburg, R., Jüni, P., Vaina, S., Hellige, G., Tsuchida, K., Morger, C., Boersma, E., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.006 · Cited by 481
Fajadet, J., Wijns, W., Laarman, G.-J., Kuck, K.-H., Ormiston, J., Münzel, T., Popma, J. J., Fitzgerald, P. J., Bonan, R., & Kuntz, R. E. (2006) · Circulation · doi:10.1161/circulationaha.105.591206 · Cited by 464
Morice, M.-C., Colombo, A., Meier, B., Serruys, P., Tamburino, C., Guagliumi, G., Sousa, E., Stoll, H.-P., & REALITY Trial Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.295.8.895 · Cited by 458
Serruys, P. W. J. C., Ruygrok, P., Neuzner, J., Piek, J. J., Seth, A., Schofer, J. J., Richardt, G., Wiemer, M., Carrié, D., Thuesen, L., et al. (2006) · EuroIntervention · doi:10.4244/eijv2i3a53 · Cited by 376
Schömig, A., Dibra, A., Windecker, S., Mehilli, J., Suárez de Lezo, J., Kaiser, C., Park, S.-J., Goy, J.-J., Lee, J.-H., Di Lorenzo, E., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.047 · Cited by 359
Kandzari, D. E., Leon, M. B., Popma, J. J., Fitzgerald, P. J., O’Shaughnessy, C., Ball, M. W., Turco, M., Applegate, R. J., Gurbel, P. A., Midei, M. G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.035 · Cited by 347
de la Torre-Hernández, J. M., Alfonso, F., Hernández, F., Elizaga, J., Sanmartin, M., Pinar, E., Lozano, I., Vazquez, J. M., Botas, J., Perez de Prado, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.057 · Cited by 311
Kastrati, A., Dibra, A., Eberle, S., Mehilli, J., Suárez de Lezo, J., Goy, J.-J., Ulm, K., & Schömig, A. (2005) · JAMA · doi:10.1001/jama.294.7.819 · Cited by 282
Leon, M. B., Mauri, L., Popma, J. J., Cutlip, D. E., Nikolsky, E., O'Shaughnessy, C., Overlie, P. A., McLaurin, B. T., Solomon, S. L., Douglas, J. S., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.067 · Cited by 241
Long-Term Safety and Efficacy of Drug-Eluting versus Bare-Metal Stents in Sweden
James, S. K., Stenestrand, U., Lindbäck, J., Carlsson, J., Scherstén, F., Nilsson, T., Wallentin, L., & Lagerqvist, B. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0809902 · Cited by 237
Self-citationKastrati, A., Dibra, A., & Eberle, S. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.10.047 · Cited by 235
Long-Term Clinical Outcomes With Sirolimus-Eluting Coronary Stents
Morice, M.-C., Serruys, P. W., Barragan, P., Bode, C., Van Es, G.-A., Stoll, H.-P., Snead, D., Mauri, L., Cutlip, D. E., & Sousa, E. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.06.029 · Cited by 224
A Prospective, Randomized Evaluation of a Novel Everolimus-Eluting Coronary Stent
Stone, G. W., Teirstein, P. S., Meredith, I. T., Farah, B., Dubois, C. L., Feldman, R. L., Dens, J., Hagiwara, N., Allocco, D. J., & Dawkins, K. D. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.02.016 · Cited by 204
Yeung, A. C., Leon, M. B., Jain, A., Tolleson, T. R., Spriggs, D. J., Laurin, B. T. M., Popma, J. J., Fitzgerald, P. J., Cutlip, D. E., Massaro, J. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.03.005 · Cited by 155
Park, D., Kim, Y., Yun, S., Kang, S., Lee, S., Lee, C. W., Park, S., In-Whan, S., Lee, J.-H., Seung-Jea, T., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.03.086 · Cited by 153
Lagerqvist, B., CARLSSON, J., Fröbert, O., Lindbäck, J., Scherstén, F., Stenestrand, U., & James, S. K. (2009) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.108.844985 · Cited by 127
Self-citationStefanini, G. G., Serruys, P. W. J. C., Silber, S., Khattab, A. A., van Geuns, R., Richardt, G., Buszman, P. E., Kelbæk, H., van Boven, A. J., Hofma, S. H., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.036 · Cited by 114
Clinical Follow-Up 3 Years After Everolimus- and Paclitaxel-Eluting Stents
Caixeta, A. M., Lansky, A. J., Serruys, P. W. J. C., Hermiller, J. B., Ruygrok, P., Onuma, Y., Gordon, P. C., Yaqub, M., Miquel‐Hébert, K., Veldhof, S., et al. (2010) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.07.017 · Cited by 50
Outcome of Drug-Eluting Versus Bare-Metal Stenting Used According to On- and Off-Label Criteria
CARLSSON, J., James, S. K., Lindbäck, J., Scherstén, F., Nilsson, T., Stenestrand, U., & Lagerqvist, B. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.09.067 · Cited by 32
Self-citation
Cited by
Cosentino, F., Grant, P. J., Aboyans, V., Bailey, C. J., Ceriello, A., Delgado, V., Federici, M., Filippatos, G., Grobbee, D. E., Hansen, T. B., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz486 · Cited by 4,763
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
Self-citation(2013) · European Heart Journal · doi:10.1093/eurheartj/eht108 · Cited by 1,955
(2014) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.10.013 · Cited by 609
Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease
Bønaa, K. H., Mannsverk, J., Wiseth, R., Aaberge, L., Myreng, Y., Nygård, O., Nilsen, D. W., Kløw, N.-E., Uchto, M., Trovik, T., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1607991 · Cited by 553
Metadata
- Authors
- Sarno, G., Lagerqvist, B., Fröbert, O., Nilsson, J., Olivecrona, G., Omerovic, E., Saleh, N., Venetzanos, D., & James, S.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-09
- Volume
- 33
- Issue
- 5
- Pages
- 606-613
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2109100788
- Cited by
- 378
- References
- 34
- FWCI
- 49.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.