The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
MR-IMPACT II: Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial
Open accessAbstract
AIMS: Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. METHODS AND RESULTS: In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. CONCLUSION: In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2011 Update: A Report From the American Heart Association
Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Adams, R. J., Berry, J. D., Brown, T. M., Carnethon, M. R., Dai, S., de Simone, G., Ford, E. S., et al. (2011) · Circulation · doi:10.1161/cir.0b013e3182009701 · Cited by 6,149
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191261 · Cited by 3,140
Piaggio, G., Elbourne, D. R., Pocock, S. J., Evans, S. J. W., Altman, D. G., & CONSORT Group, F. T. (2012) · JAMA · doi:10.1001/jama.2012.87802 · Cited by 2,428
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Guidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
European cardiovascular disease statistics
Allender, S. E., Scarborough, P., Peto, V., Rayner, M., Leal, J., Luengo-Fernández, R., & Gray, A. M. (2008) · Deakin Research Online (Deakin University) · Cited by 1,459
Wagner, A., Mahrholdt, H., Holly, T. A., Elliott, M. D., Regenfus, M., Parker, M., Klocke, F. J., Bonow, R. O., Kim, R. J., & Judd, R. M. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12389-6 · Cited by 1,307
Reporting of Noninferiority and Equivalence Randomized Trials: An Extension of the CONSORT Statement
Piaggio, G., Elbourne, D. R., Altman, D. G., Pocock, S. J., Evans, S. J. W., & CONSORT Group, F. T. (2006) · JAMA · doi:10.1001/jama.295.10.1152 · Cited by 1,153
Schwitter, J., Wacker, C. M., van Rossum, A. C., Lombardi, M., Al-Saadi, N., Ahlstrom, H., Dill, T., Larsson, H. B. W., Flamm, S. D., Marquardt, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm617 · Cited by 672
Self-citationSchwitter, J., Nanz, D., Kneifel, S., Bertschinger, K., Büchi, M., Knüsel, P. R., Marincek, B., Lüscher, T. F., & von Schulthess, G. K. (2001) · Circulation · doi:10.1161/01.cir.103.18.2230 · Cited by 663
Self-citationMagnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Nagel, E., Klein, C., Paetsch, I., Hettwer, S., Schnackenburg, B., Wegscheider, K., & Fleck, E. (2003) · Circulation · doi:10.1161/01.cir.0000080915.35024.a9 · Cited by 627
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Self-citationJahnke, C., Nagel, E., Gebker, R., Kokocinski, T., Kelle, S., Manka, R., Fleck, E., & Paetsch, I. (2007) · Circulation · doi:10.1161/circulationaha.106.652016 · Cited by 514
Gerber, T. C., Carr, J. J., Arai, A. E., Dixon, R. L., Ferrari, V. A., Gomes, A. S., Heller, G. V., McCollough, C. H., McNitt-Gray, M. F., Mettler, F. A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191650 · Cited by 487
Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imaging
Iskander, S., & Iskandrian, A. E. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00177-6 · Cited by 475
ACC/AHA/SCAI Practice Guidelines, February 21, 2006
(2006) · Circulation · doi:10.1161/circulationaha.106.173220 · Cited by 422
Shaw, L. J., Hachamovitch, R., Berman, D. S., Marwick, T. H., Lauer, M. S., Heller, G. V., Iskandrian, A. E., Kesler, K. L., Travin, M. I., Lewin, H. C., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00606-8 · Cited by 353
Hendel, R. C., Berman, D. S., Cullom, S. J., Follansbee, W., Heller, G. V., Kiat, H., Groch, M. W., & Mahmarian, J. J. (1999) · Circulation · doi:10.1161/01.cir.99.21.2742 · Cited by 236
Giang, T. V., Nanz, D., Coulden, R. A., Friedrich, M. G., Graves, M. J., Al‐Saadi, N., Lüscher, T. F., vonSchulthess, G., & Schwitter, J. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.037 · Cited by 211
Self-citationIshida, N., Sakuma, H., Motoyasu, M., Okinaka, T., Isaka, N., Nakano, T., & Takeda, K. (2003) · Radiology · doi:10.1148/radiol.2291021118 · Cited by 208
[Guidelines for percutaneous coronary interventions].
Silber, S., Albertsson, P., Fernández‐Avilés, F., Camici, P. G., Colombo, A., Hamm, C. W., Jørgensen, E. O., Marco, J., Nordrehaug, J.-E., Rużyłło, W., et al. (2005) · PubMed · Cited by 201
EuroCMR (European Cardiovascular Magnetic Resonance) Registry
Bruder, O., Schneider, S., Nothnagel, D., Dill, T., Hombach, V., Schulz-Menger, J., Nagel, E., Lombardi, M., van Rossum, A. C., Wagner, A., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.07.003 · Cited by 187
Self-citationPlein, S., Kozerke, S., Sürder, D., Lüscher, T. F., Greenwood, J. P., Boesiger, P., & Schwitter, J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn297 · Cited by 111
Self-citationAcute Adverse Reactions to Gadolinium-Based Contrast Agents in CMR
Bruder, O., Schneider, S., Nothnagel, D., Pilz, G., Lombardi, M., Sinha, A. M., Wagner, A., Dill, T., Frank, H., van Rossum, A. C., et al. (2011) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2011.06.019 · Cited by 86
Self-citationClinical e valuation of magnetic resonance imaging in coronary heart disease: The CE-MARC study
Greenwood, J. P., Maredia, N., Radjenovic, A., Brown, J. M., Nixon, J., Farrin, A. J., Dickinson, C. J., Younger, J. F., Ridgway, J. P., Sculpher, M., et al. (2009) · Trials · doi:10.1186/1745-6215-10-62 · Cited by 67
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu282 · Cited by 1,656
Gulati, M., Levy, P. D., Mukherjee, D., Amsterdam, E., Bhatt, D. L., Birtcher, K. K., Blankstein, R., Boyd, J., Bullock-Palmer, R. P., Conejo, T., et al. (2021) · Circulation · doi:10.1161/cir.0000000000001029 · Cited by 1,611
Metadata
- Authors
- Schwitter, J., Wacker, C. M., Wilke, N., Al-Saadi, N., Sauer, E., Huettle, K., Schönberg, S. O., Luchner, A., Strohm, O., Ahlstrom, H., Dill, T., Hoebel, N., Simor, T., & for the MR-IMPACT Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-03-04
- Volume
- 34
- Issue
- 10
- Pages
- 775-781
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2129884887
- Cited by
- 456
- References
- 25
- FWCI
- 34.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.