Imaging of myocardial infarction using ultrasmall superparamagnetic iron oxide nanoparticles: a human study using a multi-parametric cardiovascular magnetic resonance imaging approach
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: The purpose of this clinical trial was to investigate whether cardiovascular magnetic resonance imaging (CMR) using ferumoxytol (Feraheme™, FH), an ultrasmall superparamagnetic iron oxide nanoparticle (USPIO), allows more detailed characterization of infarct pathology compared with conventional gadolinium-based necrosis/fibrosis imaging in patients with acute myocardial infarction. METHODS AND RESULTS: Fourteen patients who had experienced an acute ST-elevation myocardial infarction were included in this study. Following coronary angiography, a first baseline study (pre-FH) was performed followed by subsequent CMR studies (post-FH) 48 h after intravenous ferumoxytol administration. The CMR studies comprised cine-CMR, T(2)-weighted short tau inversion recovery spin echo imaging, T(2)-mapping, and T(1)-weighted late gadolinium enhancement (LGE) imaging. The median extent of short-axis in-plane LGE was 30% [inter-quartile range (IQR) 26-40%]. The median in-plane extent of T(2)-weighted 'hypoenhancement' in the region of myocardial infarction, which was not present prior to ferumoxytol administration in any patient, was 19% (IQR 14-22%; P < 0.001 compared with the extent of LGE). The median in-plane extent of areas showing signal void in T(2)-mapping images post-FH in the region of myocardial infarction was 16% (IQR 12-18%; P < 0.001 compared with the extent of LGE; P = 0.34 compared with the extent of T(2)-weighted hypoenhancement). A substantial drop in absolute T(2)-values was observed not only in the infarct core and peri-infarct zone, but also in the remote 'healthy' myocardium, although there was only a minor change in the skeletal muscle. Substantial ferumoxytol uptake was detected only in cultured macrophages, but not in peripheral blood monocytes from study patients. CONCLUSION: We could demonstrate in humans that USPIO-based contrast agents enable a more detailed characterization of myocardial infarct pathology mainly by detecting infiltrating macrophages. Considering the multi-functionality of USPIO-based particles and their superior safety profile compared with gadolinium-based compounds, these observations open up new vistas for the clinical application of USPIO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500 · cited 1×
“5 T) and a blood half-life of 15 h.(16) It has been developed by AMAG Pharmaceuticals, Inc.”
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Imaging macrophages with nanoparticles
Weissleder, R., Nahrendorf, M., & Pittet, M. J. (2014) · Nature Materials · doi:10.1038/nmat3780 · Cited by 809
Inflammatory processes in cardiovascular disease: a route to targeted therapies
Ruparelia, N., Chai, J. T., Fisher, E. A., & Choudhury, R. P. (2017) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.185 · Cited by 477
Jeon, M., Halbert, M. V., Stephen, Z. R., & Zhang, M. (2021) · Advanced Materials · doi:10.1002/adma.201906539 · Cited by 477
Application of Light Scattering Techniques to Nanoparticle Characterization and Development
Carvalho, P. M., Felício, M. R., Santos, N. C., Gonçalves, S., & Domingues, M. M. (2018) · Frontiers in Chemistry · doi:10.3389/fchem.2018.00237 · Cited by 402
Metadata
- Authors
- Yilmaz, A., Dengler, M. A., van der Kuip, H., Yildiz, H., Rösch, S., Klumpp, S., Klingel, K., Kandolf, R., Helluy, X., Hiller, K.-H., Jakob, P. M., & Sechtem, U.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-10-26
- Volume
- 34
- Issue
- 6
- Pages
- 462-475
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2130710122
- Cited by
- 149
- References
- 1
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.