CoChat

Identification of a loss-of-function inducible degrader of the low-density lipoprotein receptor variant in individuals with low circulating low-density lipoprotein

Open access
Sorrentino, V., Fouchier, S. W., Motazacker, M. M., Nelson, J. K., Defesche, J. C., Dallinga-Thie, G. M., Kastelein, J. J. P., Kees Hovingh, G., Zelcer, N. · 2013 · European Heart Journal
Cited by 58

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

AIMS: Recent genome-wide association studies suggest that IDOL (also known as MYLIP) contributes to variation in circulating levels of low-density lipoprotein cholesterol (LDL-C). IDOL, an E3-ubiquitin ligase, is a recently identified post-transcriptional regulator of LDLR abundance. Briefly, IDOL promotes degradation of the LDLR thereby limiting LDL uptake. Yet the exact role of IDOL in human lipoprotein metabolism is unclear. Therefore, this study aimed at identifying and functionally characterizing IDOL variants in the Dutch population and to assess their contribution to circulating levels of LDL-C. METHODS AND RESULTS: We sequenced the IDOL coding region in 677 individuals with LDL-C above the 95th percentile adjusted for age and gender (high-LDL-C cohort) in which no mutations in the LDLR, APOB, and PCSK9 could be identified. In addition, IDOL was sequenced in 560 individuals with baseline LDL-C levels below the 20th percentile adjusted for age and gender (low-LDL-C cohort). We identified a total of 14 IDOL variants (5 synonymous, 8 non-synonymous, and 1 non-sense). Functional characterization of these variants demonstrated that the p.Arg266X variant represents a complete loss of IDOL function unable to promote ubiquitylation and subsequent degradation of the LDLR. Consistent with loss of IDOL function, this variant was identified in individuals with low circulating LDL-C. CONCLUSION: Our results support the notion that IDOL contributes to variation in circulating levels of LDL-C. Strategies to inhibit IDOL activity may therefore provide a novel therapeutic venue to treating dyslipidaemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehs472

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 58

Metadata

Authors
Sorrentino, V., Fouchier, S. W., Motazacker, M. M., Nelson, J. K., Defesche, J. C., Dallinga-Thie, G. M., Kastelein, J. J. P., Kees Hovingh, G., & Zelcer, N.
Venue
European Heart Journal
Published
2013-01-16
Volume
34
Issue
17
Pages
1292-1297
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2131577329
Cited by
58
References
17
FWCI
6.89
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of a loss-of-function inducible degrader of the low-density lipoprotein receptor variant in individuals with low circulating low-density lipoprotein. https://app.cochat.ai/papers/10.1093/eurheartj/ehs472
The paper
Sorrentino, V., Fouchier, S. W., Motazacker, M. M., Nelson, J. K., Defesche, J. C., Dallinga-Thie, G. M., Kastelein, J. J. P., Kees Hovingh, G., & Zelcer, N. (2013). Identification of a loss-of-function inducible degrader of the low-density lipoprotein receptor variant in individuals with low circulating low-density lipoprotein. European Heart Journal. https://doi.org/10.1093/eurheartj/ehs472

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.