Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 462

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry

Open access
Lambiase, Pier D., Barr, Craig, Theuns, Dominic A.M.J., Knops, Reinoud, Neuzil, Petr, Johansen, Jens Brock, Hood, Margaret, Pedersen, Susanne, Kääb, Stefan, Murgatroyd, Francis, Reeve, Helen L., Carter, Nathan, Boersma, Lucas, on behalf of the EFFORTLESS Investigators, Adragão, P., Agarwal, S., Barr, C., Boersma, L., Brock-Johanssen, J., Butter, C., Calò, L., Eckhardt, L., Gulizia, M., Scholten, M., Dekker, L., Khiani, R., Hjortshot, S., Høgh Petersen, H., Hood, M., Kääb, S., Knops, R., Kuschyk, J., Lambiase, P., Maass, K. A., McLeod, K., Molon, G., Morgan, J., Mortensen, P., Murgatroyd, F., Neuzil, P., Pepper, C., Sheridan, P., Stellbrink, C., Stuart, G., Theuns, D., Vernooy, K., Veltmann, C., Wende, C.·2014·European Heart Journal

Abstract

AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large international patient population collected as part of the EFFORTLESS S-ICD Registry. METHODS AND RESULTS: The EFFORTLESS S-ICD Registry is a non-randomized, standard of care, multicentre Registry designed to collect long-term, system-related, clinical, and patient reported outcome data from S-ICD implanted patients since June 2009. Follow-up data are systematically collected over 60-month post-implant including Quality of Life. The study population of 472 patients of which 241 (51%) were enrolled prospectively has a mean follow-up duration of 558 days (range 13-1342 days, median 498 days), 72% male, mean age of 49 ± 18 years (range 9-88 years), 42% mean left ventricular ejection fraction. Complication-free rates were 97 and 94%, at 30 and 360 days, respectively. Three hundred and seventeen spontaneous episodes were recorded in 85 patients during the follow-up period. Of these episodes, 169 (53%) received therapy, 93 being for Ventricular Tachycardia/Fibrillation (VT/VF). One patient died of recurrent VF and severe bradycardia. Regarding discrete VT/VF episodes, first shock conversion efficacy was 88% with 100% overall successful clinical conversion after a maximum of five shocks. The 360-day inappropriate shock rate was 7% with the vast majority occurring for oversensing (62/73 episodes), primarily of cardiac signals (94% of oversensed episodes). CONCLUSION: The first large cohort of real-world data from an International patient S-ICD population demonstrates appropriate system performance with clinical event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehu112

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Cited by

See all 462

Metadata

Authors
Lambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., Reeve, H. L., Carter, N., Boersma, L., on behalf of the EFFORTLESS Investigators, Adragão, P., Agarwal, S., Barr, C., Boersma, L., Brock-Johanssen, J., Butter, C., Calò, L., Eckhardt, L., Gulizia, M., Scholten, M., Dekker, L., Khiani, R., Hjortshot, S., Høgh Petersen, H., Hood, M., Kääb, S., Knops, R., Kuschyk, J., Lambiase, P., Maass, K. A., McLeod, K., Molon, G., Morgan, J., Mortensen, P., Murgatroyd, F., Neuzil, P., Pepper, C., Sheridan, P., Stellbrink, C., Stuart, G., Theuns, D., Vernooy, K., Veltmann, C., & Wende, C.
Venue
European Heart Journal
Published
2014-03-26
Volume
35
Issue
25
Pages
1657-1665
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2032366440
Cited by
462
References
38
FWCI
44.43
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry. https://app.cochat.ai/papers/10.1093/eurheartj/ehu112
The paper
Lambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., Reeve, H. L., Carter, N., Boersma, L., on behalf of the EFFORTLESS Investigators, Adragão, P., Agarwal, S., Barr, C., Boersma, L., Brock-Johanssen, J., . . . Wende, C. (2014). Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry. European Heart Journal. https://doi.org/10.1093/eurheartj/ehu112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.