Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study
Open accessAbstract
AIM: Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre 'real-world' patient population in highly experienced centres. METHODS AND RESULTS: Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. CONCLUSION: The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
Self-citationDecision-making in elderly patients with severe aortic stenosis: why are so many denied surgery?
Iung, B., Cachier, A., Baron, G., Messika-Zeitoun, D., Delahaye, F., Tornos, P., Gohlke-Bärwolf, C., Boersma, E., Ravaud, P., & Vahanian, A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi471 · Cited by 1,108
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Self-citation
Cited by
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Haussig, S., Mangner, N., Dwyer, M. G., Lehmkuhl, L., Lücke, C., Woitek, F., Holzhey, D. M., Mohr, F. W., Gutberlet, M., Zivadinov, R., et al. (2016) · JAMA · doi:10.1001/jama.2016.10302 · Cited by 367
Self-citationvan Rosendael, P. J., Delgado, V., & Bax, J. J. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx785 · Cited by 292
Metadata
- Authors
- Linke, A., Wenaweser, P., Gerckens, U., Tamburino, C., Bosmans, J., Bleiziffer, S., Blackman, D., Schafer, U., Muller, R., Sievert, H., Sondergaard, L., Klugmann, S., Hoffmann, R., Tchetche, D., Colombo, A., Legrand, V. M., Bedogni, F., lePrince, P., Schuler, G., Mazzitelli, D., Eftychiou, C., Frerker, C., Boekstegers, P., Windecker, S., Mohr, F.-W., Woitek, F., Lange, R., Bauernschmitt, R., Brecker, S., & For the ADVANCE study Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-03-28
- Volume
- 35
- Issue
- 38
- Pages
- 2672-2684
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2102679179
- Cited by
- 206
- References
- 5
- FWCI
- 26.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study. https://app.cochat.ai/papers/10.1093/eurheartj/ehu162
- The paper
- Linke, A., Wenaweser, P., Gerckens, U., Tamburino, C., Bosmans, J., Bleiziffer, S., Blackman, D., Schafer, U., Muller, R., Sievert, H., Sondergaard, L., Klugmann, S., Hoffmann, R., Tchetche, D., Colombo, A., Legrand, V. M., Bedogni, F., lePrince, P., Schuler, G., . . . For the ADVANCE study Investigators. (2014). Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study. European Heart Journal. https://doi.org/10.1093/eurheartj/ehu162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.