Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
AIM: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) remains uncertain. In this analysis, we sought to evaluate the impact of varying degrees of PVR on both mortality and changes in ventricular geometry and function. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent TAVR from the randomized cohorts and continued access registries in the PARTNER trial were analysed after stratifying by severity of post-implant PVR, which was graded as none/trace in 52.9% (n = 1288), mild in 38.0% (n = 925), and moderate/severe in 9.1% (n = 221). There were significant differences in baseline clinical and echocardiographic characteristics. After TAVR, all the patients demonstrated increase in left ventricular (LV) function and reduction in the LV mass index, although the magnitude of mass regression was lower in the moderate/severe PVR group. The 30-day mortality (3.1 vs. 3.4 vs. 4.5%, P = 0.56) and stroke (3.4 vs. 3.7 vs. 2.3%, P = 0.59) were similar in all groups (none/trace, mild, and moderate/severe). At 1 year, there was increased all-cause mortality (15.9 vs. 22.2 vs. 35.1%, P < 0.0001), cardiac mortality (6.1 vs. 7.4% vs. 16.3%, P < 0.0001) and re-hospitalization (14.4 vs. 23.0 vs. 31.3%, P < 0.0001) with worsening PVR. A multivariable analysis indicated that the presence of moderate/severe PVR (HR: 2.18, 95% CI: 1.57-3.02, P < 0.0001) or mild PVR (HR: 1.37, 95% CI: 1.14-1.90, P = 0.012) was associated with higher late mortality. CONCLUSION: Differences in baseline characteristics in patients with increasing severities of PVR may increase the risk of this complication. Despite these differences, multivariable analysis demonstrated that both mild and moderate/severe PVR predicted higher 1-year mortality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The association between moderate or severe paravalvular aortic regurgitation and increased mortality has been clearly established”
From Calcific aortic stenosis (2016) · cites this paper as [237]
In the citing paper
“with some studies even suggesting that this adverse association extends to mild regurgitation235;237;238.”
From Calcific aortic stenosis (2016) · cites this paper as [237]
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationZoghbi, W. A., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Kraft, C. D., Levine, R. A., Nihoyannopoulos, P., Otto, C. M., Quinones, M. A., Rakowski, H., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00335-3 · Cited by 4,044
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationUpdated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citationTamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Research works printed but not linked: 1
- 2012, New England Journal of Medicine, 366, 1686, 10.1056/nejmoa1200384 · DOI · Paper page
Cited by
Items 101–200 of 476
Sawaya, F., Spaziano, M., Lefèvre, T., Roy, A. K., Garot, P., Hovasse, T., Neylon, A. M., Benamer, H., Romano, M., Unterseeh, T., et al. (2016) · World Journal of Cardiology · doi:10.4330/wjc.v8.i12.735 · Cited by 36
Techniques and outcomes of paravalvular leak repair after transcatheter aortic valve replacement
Waterbury, T. M., Reeder, G. S., Pislaru, S. V., Cabalka, A. K., Rihal, C. S., & Eleid, M. F. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27224 · Cited by 35
Self-citationCharacteristics and longer-term outcomes of paravalvular leak after aortic and mitral valve surgery
Shah, S. Y., Alashi, A., Pettersson, G., Rodriguez, L. L., Gillinov, A. M., Grimm, R. A., Navia, J. L., Kapadia, S. R., Svensson, L. G., Griffin, B. P., et al. (2018) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2018.08.096 · Cited by 34
Self-citationBiase, C. D., Mastrokostopoulos, A., Philippart, R., Desroche, L. M., Blanco, S., Rehal, K., Dumonteil, N., & Tchétché, D. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.01.018 · Cited by 34
Hioki, H., Yamamoto, M., Shirai, S., Ohno, Y., Yashima, F., Naganuma, T., Yamawaki, M., Watanabe, Y., Yamanaka, F., Mizutani, K., et al. (2024) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2024.08.049 · Cited by 34
Ochiai, T., Yoon, S., Sharma, R. P., Miyasaka, M., Nomura, T., Rami, T., Maeno, Y., Chakravarty, T., Nakamura, M., Cheng, W., et al. (2018) · Circulation Journal · doi:10.1253/circj.cj-18-0157 · Cited by 34
Maisano, F., Taramasso, M., & Nietlispach, F. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu410 · Cited by 33
Schmidt, S., Fortmeier, V., Ludwig, S., Wienemann, H., Körber, M. I., Lee, S., Meertens, M. M., Macherey‐Meyer, S., Iliadis, C., Kuhn, E. W., et al. (2022) · Clinical Research in Cardiology · doi:10.1007/s00392-022-02046-7 · Cited by 33
Yokoyama, H., Sugiyama, Y., Miyashita, H., Jalanko, M., Ochiai, T., Shishido, K., Yamanaka, F., Vähäsilta, T., Saito, S., Laine, M., et al. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2022.12.002 · Cited by 32
Insights into permanent pacemaker implantation following TAVR in a real-world cohort
Tichelbäcker, T., Bergau, L., Puls, M., Friede, T., Mütze, T., Maier, L. S., Frey, N., Hasenfuss, G. P., Zabel, M., Jacobshagen, C., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204503 · Cited by 30
Scotti, A., Baggio, S., Pagnesi, M., Barbanti, M., Adamo, M., Eitan, A., Estévez‐Loureiro, R., Veulemans, V., Toggweiler, S., Mylotte, D., et al. (2023) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.122.012538 · Cited by 30
Rogers, T., & Waksman, R. (2016) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2016.01.011 · Cited by 30
D’Ascenzo, F., Bruno, F., Baldetti, L., FILIPPO, O. D., Marengo, G., Breviario, S., Melillo, F., Thyregod, H. G. H., Thiele, H., Søndergaard, L., et al. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.04.068 · Cited by 30
Self-citationOptimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation
Rocatello, G., Santis, G. D., Bock, S. D., Beule, M. D., Segers, P., & Mortier, P. (2019) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-019-00420-7 · Cited by 29
Transcatheter Treatment of Bicuspid Aortic Valve Disease: Imaging and Interventional Considerations
Das, R., & Puri, R. (2018) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2018.00091 · Cited by 29
Kılıç, T., & Yılmaz, İ. (2017) · PubMed Central · doi:10.11909/j.issn.1671-5411.2017.03.002 · Cited by 29
Vilalta, V., Alperi, A., Cediel, G., Mohammadi, S., Fernández‐Nofrerías, E., Kalvrouziotis, D., DeLarochellière, R., Paradis, J., González-Lopera, M., Fadeuilhe, E., et al. (2021) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.121.011120 · Cited by 29
Transcatheter vs Surgical Aortic Valve Replacement in Pure Native Aortic Regurgitation
Mentias, A. G., Saad, M. S., Menon, V., Reed, G. W., Popović, Z., Johnston, D. R., Rodríguez, L., Gillinov, M., Griffin, B. P., Jneid, H. M., et al. (2022) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2022.09.016 · Cited by 29
Self-citationTang, G. H. L., Zaid, S., Schnittman, S. R., Ahmad, H. A., Kaple, R., Undemir, C., Dutta, T., Poniros, A., Bennett, J., Feng, C., et al. (2018) · EuroIntervention · doi:10.4244/eij-d-18-00005 · Cited by 29
Seeger, J., Gonska, B., Rottbauer, W., & Wöhrle, J. (2017) · Cardiovascular Intervention and Therapeutics · doi:10.1007/s12928-017-0477-6 · Cited by 29
Wöhrle, J., Gonska, B., Rodewald, C., Seeger, J., Scharnbeck, D., & Rottbauer, W. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151247 · Cited by 29
Current issues in transcatheter aortic valve replacement
Mas‐Peiró, S., Fichtlscherer, S., Walther, C., & Vasa‐Nicotera, M. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd.2020.01.10 · Cited by 29
Effect of a fourth‐generation transcatheter valve enhanced skirt on paravalvular leak
Welle, G. A., El-Sabawi, B. R., Thaden, J. J., Greason, K. L., Klarich, K. W., Nkomo, V. T., Alkhouli, M. A., Guerrero, M. E., Crestanello, J. A., Holmes, D. R., et al. (2020) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.29317 · Cited by 28
Self-citationAbdelghani, M., Tateishi, H., Spitzer, E., Tijssen, J. G. P., de Winter, R. J., Soliman, O. I. I., Hahn, R. T., & Serruys, P. W. J. C. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew083 · Cited by 28
Self-citationAbdelghani, M., Miyazaki, Y., de Boer, E., Aben, J., van Sloun, M., Suchecki, T., Veer, M. V. ’., Soliman, O. I. I., Onuma, Y., de Winter, R. J., et al. (2018) · EuroIntervention · doi:10.4244/eij-d-17-00595 · Cited by 28
Low Incidence of Paravalvular Leakage With the Balloon-Expandable Sapien 3 Transcatheter Heart Valve
Wendt, D., Al‐Rashid, F., Kahlert, P., Eißmann, M., Chilali, K. E., Jánosi, R. A., Pasa, S., Tsagakis, K., Liakopoulos, O. J., Erbel, R., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.03.079 · Cited by 28
Gupta, R., Mahmoudi, E., Behnoush, A. H., Khalaji, A., Malik, A. H., Sood, A., Bandyopadhyay, D., Zaid, S., Goel, A., Sreenivasan, J., et al. (2023) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2022.12.006 · Cited by 27
TAVR in 2023: Who Should Not Get It?
Bhogal, S. S., Rogers, T., Aladin, A. I., Ben‐Dor, I., Cohen, J. E., Shults, C., Wermers, J. P., Weissman, G., Satler, L. F., Reardon, M. J., et al. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.01.040 · Cited by 27
Seiffert, M., Treede, H., Schöfer, J., Linke, A. H.-P., Wöehrle, J., Baumbach, H., Mehilli, J., Bapat, V., Simonato, M., Walther, T., et al. (2018) · EuroIntervention · doi:10.4244/eij-d-17-00546 · Cited by 27
Intermediate Clinical and Hemodynamic Outcomes After Transcatheter Aortic Valve Implantation
D’Onofrio, A., Facchin, M., Besola, L., Manzan, E., Tessari, C., Bizzotto, E., Bianco, R., Tarantini, G., Napodano, M., Fraccaro, C., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2015.08.032 · Cited by 26
Head, S. J., Reardon, M. J., Deeb, G. M., Mieghem, N. M. V., Popma, J. J., Gleason, T. G., Williams, M. R., Radhakrishnan, S., Fremes, S. E., Oh, J. K., et al. (2019) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.118.007396 · Cited by 26
Self-citationHu, Q., Li, Y., Ren, Q., Liang, Y., Zhang, J., Wang, Y., Wang, C., Hong, T.-L., Wang, S., Zhang, Y., et al. (2023) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2023.04.025 · Cited by 25
Rao, G., Sheth, S., Donnelly, J., Scatola, A., Tariq, U., Laighold, S., Grines, C. L., & Rutkin, B. J. (2019) · Journal of Interventional Cardiology · doi:10.1155/2019/1906814 · Cited by 25
CT in planning transcatheter aortic valve implantation procedures and risk assessment
Yucel-Finn, A., Nicol, E. D., Leipsic, J. A., & Weir-McCall, J. R. (2019) · Clinical Radiology · doi:10.1016/j.crad.2019.11.015 · Cited by 25
Colli, A., Besola, L., Salizzoni, S., Gregori, D., Tarantini, G., Agrifoglio, M., Chieffo, A., Regesta, T., Gabbieri, D., Saia, F., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.005 · Cited by 25
Dowling, C., Seshasai, S. R. K., Firoozi, S., & Brecker, S. J. (2019) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28504 · Cited by 25
Fovino, L. N., Badawy, M. R. A., Fraccaro, C., D’Onofrio, A., Purita, P., Frigo, A. C., Tellaroli, P., Agnifili, M., Tusa, M. B., Napodano, M., et al. (2018) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000705 · Cited by 25
Gonska, B., Seeger, J., Baarts, J., Rodewald, C., Scharnbeck, D., Rottbauer, W., & Wöhrle, J. (2016) · Journal of Cardiology · doi:10.1016/j.jjcc.2016.08.008 · Cited by 25
Muratori, M., Fusini, L., Tamborini, G., Gripari, P., Alì, S. G., Mapelli, M., Fabbiocchi, F., Trabattoni, P., Roberto, M., Agrifoglio, M., et al. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jex046 · Cited by 24
Predilatation Prior to Transcatheter Aortic Valve Implantation: Is it Still a Prerequisite?
Pagnesi, M., Baldetti, L., Sole, P. A. D., Mangieri, A., Ancona, M., Regazzoli, D., Buzzatti, N., Giannini, F., Colombo, A., & Latib, A. (2017) · Interventional Cardiology Reviews Research Resources · doi:10.15420/icr.2017:17:2 · Cited by 23
Evolving Devices and Material in Transcatheter Aortic Valve Replacement: What to Use and for Whom
Chiarito, M., Spirito, A., Nicolas, J., Selberg, A. M., Stefanini, G. G., Colombo, A., Reimers, B., Kini, A. S., Sharma, S. K., Dangas, G., et al. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11154445 · Cited by 23
Seeger, J., Gonska, B., Rottbauer, W., & Wöhrle, J. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.116.004670 · Cited by 23
Ki, Y., Kang, J., Lee, H. S., Chang, M., Han, J., Yang, H., Park, K. W., Kang, H., Koo, B., & Kim, H.-S. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9123936 · Cited by 23
Miyasaka, M., Yoon, S., Sharma, R. P., Maeno, Y., Sandhu, J. S., Taguri, M., Kato, S., Kawamori, H., Nomura, T., Ochiai, T., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-18-1059 · Cited by 22
Is it the time to reconsider the choice of valves for cardiac surgery: mechanical or bioprosthetic?
Patricia, M., Douglas, W., Richard, L., & Liu, H. (2017) · Journal of Biomedical Research · doi:10.7555/jbr.31.20170027 · Cited by 22
Eschalier, R., Massoullié, G., Nahli, Y., Jean, F., Combaret, N., Ploux, S., Souteyrand, G., Chabin, X., Bosle, R., Lambert, C., et al. (2019) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2019.05.012 · Cited by 22
Schaefer, A., Linder, M., Seiffert, M., Schoen, G., Deuschl, F. G., Schofer, N., Schneeberger, Y., Blankenberg, S., Reichenspurner, H. C., Schäfer, U., et al. (2017) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivx194 · Cited by 22
Cannata, S., Sultan, I. S., Mieghem, N. M. V., Giordano, A., Backer, O. D., Byrne, J., Tchétché, D., Buccheri, S., y, L. N.-F., Teles, R. C., et al. (2025) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2025.03.015 · Cited by 21
Sanz‐Sánchez, J., Regazzoli, D., Barbanti, M., Fiorina, C., Adamo, M., Angelillis, M., Carlo, M. D., Bellini, B., Montorfano, M., Mangieri, A., et al. (2023) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.30907 · Cited by 21
Impact of Annular Oversizing on Paravalvular Regurgitation and Valve Hemodynamics
Ihdayhid, A. R., Leipsic, J. A., Hahn, R. T., Pîbarot, P., Thourani, V. H., Makkar, R., Kodali, S., Russo, M. J., Kapadia, S. R., Chen, Y., et al. (2021) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2021.07.018 · Cited by 21
Self-citationCannata, S., Gandolfo, C. M., Ribichini, F. L., Mieghem, N. M. V., Buccheri, S., Barbanti, M., Berti, S. L., Teles, R. C., Bartorelli, A. L., Musumeci, G., et al. (2023) · EuroIntervention · doi:10.4244/eij-d-22-01022 · Cited by 21
Modolo, R., Chang, C., Tateishi, H., Miyazaki, Y., Pighi, M., Abdelghani, M., Roos, M. A., Wolff, Q. M., Wykrzykowska, J. J., de Winter, R. J., et al. (2019) · EuroIntervention · doi:10.4244/eij-d-19-00362 · Cited by 21
Yoshijima, N., Yanagisawa, R., Hase, H., Tanaka, M., Tsuruta, H., Shimizu, H., Fukuda, K., Naganuma, T., Mizutani, K., Araki, M., et al. (2019) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28279 · Cited by 20
Bocksch, W., Menden, B., Geisler, T., Steeg, M., Droppa, M., Jorbenadze, R., Haap, M. M., Gawaz, M., & Fateh‐Moghadam, S. (2016) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26562 · Cited by 21
Maeno, Y., Abramowitz, Y., Yoon, S., Israr, S., Jilaihawi, H., Watanabe, Y., Sharma, R. P., Kawamori, H., Miyasaka, M., Kazuno, Y., et al. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.08.018 · Cited by 20
Meguro, K., Kumamaru, H., Kohsaka, S., Hashimoto, T., Kakizaki, R., Kitamura, T., Shimizu, H., & Ako, J. (2021) · Circulation Journal · doi:10.1253/circj.cj-20-1084 · Cited by 20
Eftychiou, C., Eteocleous, N., Zittis, I., Simamonian, K., Ioannou, A., Loukaidou, P., Ntaka, A., Hadjigregoriou, A., Vasiliades, V., Adamou, M., et al. (2020) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2020.09.011 · Cited by 21
Transcatheter Aortic Valve Implantation – Yesterday, Today and Tomorrow
Gooley, R., Cameron, J. D., & Meredith, I. T. (2015) · Heart Lung and Circulation · doi:10.1016/j.hlc.2015.07.017 · Cited by 20
Transcatheter Aortic Valve Replacement: Outcomes, Indications, Complications, and Innovations
Young, M. N., & Inglessis, I. (2017) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-017-0580-0 · Cited by 19
Miyazaki, Y., Abdelghani, M., de Boer, E., Aben, J., van Sloun, M., Suchecki, T., Veer, M. V. ’., Collet, C. A., Asano, T., Katagiri, Y., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00355 · Cited by 19
Meredith, I. T., Dumonteil, N., Blackman, D., Tchétché, D., Walters, D., Hildick‐Smith, D., Manoharan, G., Harnek, J., Worthley, S. G., Rioufol, G., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-16-01024 · Cited by 18
Eckel, C. E., Kim, W.-K., Grothusen, C., Tiyerili, V., Elsässer, A., Sötemann, D., Schlüter, J., Choi, Y., Charitos, E. I., Renker, M., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12123999 · Cited by 18
A new calcium score to predict paravalvular leak in transcatheter aortic valve implantation
Kofler, M., Meyer, A., Schwartz, J., Sündermann, S., Penkalla, A., Solowjowa, N., Klein, C. A., Unbehaun, A., Falk, V., & Kempfert, J. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezaa424 · Cited by 17
Hahn, R. T., Ternacle, J., Silva, I., Giuliani, C., Zanuttini, A., Théron, A., Cristell, N. A., Bernier, M., Skaf, S., Beaudoin, J., et al. (2025) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2025.01.015 · Cited by 17
Self-citationTateishi, H., Abdelghani, M., Cavalcante, R., Miyazaki, Y., Campos, C. M., Collet, C. A., Slots, T., Leite, R. S., Mangione, J. A., Abizaid, A., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-16-00647 · Cited by 17
Blackman, D. J., Meredith, I. T., Dumonteil, N., Tchétché, D., Hildick‐Smith, D., Spence, M. S., Walters, D., Harnek, J., Worthley, S. G., Rioufol, G., et al. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.04.026 · Cited by 17
Zadok, O. I. B., Kornowski, R., Finkelstein, A., Barbash, I. M., Danenberg, H. D., Segev, A., Guetta, V., Halkin, A., Vaknin, H., Planer, D., et al. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.09.018 · Cited by 17
Miyazaki, Y., Modolo, R., Abdelghani, M., Tateishi, H., Cavalcante, R., Collet, C. A., Asano, T., Katagiri, Y., Tenekecioğlu, E., Sarmento‐Leite, R., et al. (2018) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20180139 · Cited by 17
Rudolph, T. K., Herrmann, E. M., Bon, D., Walther, T., Bauer, T., Ensminger, S. M., Frerker, C., Beckmann, A., Möllmann, H., Bekeredjian, R., et al. (2023) · Clinical Research in Cardiology · doi:10.1007/s00392-023-02242-z · Cited by 17
Oh, J. K., Lee, S. H., Lee, S., Kang, D., Lee, S., Kim, H. J., Ahn, J., Kim, J. B., Park, D., Song, J., et al. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.03.053 · Cited by 17
Modolo, R., Serruys, P. W. J. C., Chang, C. C., Wöhrle, J., Hildick‐Smith, D., Bleiziffer, S., Blackman, D. J., Abdel‐Wahab, M., Onuma, Y., Soliman, O. I. I., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.11.004 · Cited by 17
Perrin, N., Roffi, M., Frei, A., Hachulla, A.-L., Ellenberger, C., Müller, H., Çıkırıkçıoğlu, M., Licker, M. J., & Noble, S. (2016) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2016.11.024 · Cited by 16
Chew, N., Hon, J., Yip, W., Chan, S., Poh, K. K., Kong, W., Teoh, K. H., Tc, Y., Tan, H., & Tay, E. (2017) · Singapore Medical Journal · doi:10.11622/smedj.2016128 · Cited by 16
Piroli, F., Franchin, L., Bruno, F., FILIPPO, O. D., D’Ascenzo, F., & Conrotto, F. (2020) · Kardiologia Polska · doi:10.33963/kp.15522 · Cited by 16
3-Dimensional–Printed Models for TAVR Planning
Alkhouli, M. A., & Sengupta, P. P. (2017) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2017.05.002 · Cited by 16
Gozdek, M., Zieliński, K., Pasierski, M., Matteucci, M., Fina, D., Jiritano, F., Meani, P., Raffa, G. M., Malvindi, P. G., Pilato, M., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020397 · Cited by 15
Ueyama, H. A., Kuno, T., Ando, T., Hayashida, K., & Takagi, H. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.02.088 · Cited by 15
Abdelghani, M., & Serruys, P. W. J. C. (2016) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.115.002944 · Cited by 15
Transcatheter aortic valve implantation: a new standard of care
Nelson, A. J., Montarello, N. J., Cosgrove, C., Roberts-Thomson, R., Delacroix, S., Chokka, R. G., Montarello, J. K., & Worthley, S. G. (2018) · The Medical Journal of Australia · doi:10.5694/mja17.01255 · Cited by 15
Comparison of Self-Expanding RDV Perceval S versus TAVI ACURATE neo/TF
Mauri, V., Gerfer, S., Kuhn, E. W., Adam, M., Eghbalzadeh, K., Djordjevic, I., Ivanov, B., Gaisendrees, C., Frerker, C., Schmidt, T., et al. (2021) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0040-1722692 · Cited by 15
Tabata, N., Al‐Kassou, B., Sugiura, A., Shamekhi, J., Sedaghat, A., Treede, H., Tsujita, K., Werner, N., Grube, E., Nickenig, G., et al. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01609-w · Cited by 15
One-Year Outcomes of Transcatheter Aortic Valve Implantation Using the Direct Aortic Approach
Bruschi, G., Branny, M., Schiltgen, M., Ettori, F., Marcheix, B., Amrane, H., Bushnaq, H. S., Tan, M., Trivedi, U., Branny, P., et al. (2016) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2016.08.080 · Cited by 15
Transcatheter aortic valve replacement in China – a review of the available evidence
Wei, L., Wang, B., Yang, Y., Dong, L., Chen, X., Bramlage, P., & Wang, Y. (2024) · AsiaIntervention · doi:10.4244/aij-d-23-00049 · Cited by 15
Schymik, G., Varsami, C., Bramlage, P., Conzelmann, L. O., Würth, A., Luik, A., Schröfel, H., & Tzamalis, P. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.02.053 · Cited by 15
Musa, T. A., Plein, S., & Greenwood, J. P. (2016) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2016.06.05 · Cited by 14
Year in review: transcatheter aortic valve replacement
Tsai, M., Tang, G. H. L., & Cohen, G. N. (2016) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000260 · Cited by 14
Yeats, B. B., Yadav, P., Dasi, L. P., & Thourani, V. H. (2022) · Current Cardiology Reports · doi:10.1007/s11886-021-01617-w · Cited by 14
Self-citationWöhrle, J., Gonska, B., Rodewald, C., Seeger, J., Scharnbeck, D., & Rottbauer, W. (2016) · EuroIntervention · doi:10.4244/eijv12i6a124 · Cited by 14
Tateishi, H., Miyazaki, Y., Okamura, T., Abdelghani, M., Modolo, R., Wada, Y., Okuda, S., Omuro, A., Ariyoshi, T., Fujii, A., et al. (2018) · Circulation Journal · doi:10.1253/circj.cj-17-1376 · Cited by 14
Outcome of Patients with Mixed Aortic Valve Disease Undergoing Transfemoral Aortic Valve Replacement
Seeger, J., Gonska, B., Mörike, J., Rottbauer, W., & Wöhrle, J. (2017) · Structural Heart · doi:10.1080/24748706.2017.1348648 · Cited by 14
Abdelshafy, M., Serruys, P. W. J. C., Kim, W., Rück, A., Wang, R., Tao, L., Elkoumy, A., Elzomor, H., Garg, S., Onuma, Y., et al. (2022) · Journal of the Society for Cardiovascular Angiography & Interventions · doi:10.1016/j.jscai.2022.100037 · Cited by 13
Yeats, B. B., Yadav, P., Dasi, L. P., & Thourani, V. H. (2022) · Annals of Cardiothoracic Surgery · doi:10.21037/acs-2022-bav-20 · Cited by 13
Self-citationQuantitative aortography assessment of aortic regurgitation
Modolo, R., Chang, C. C., Onuma, Y., Schultz, C. J., Tateishi, H., Abdelghani, M., Miyazaki, Y., Aben, J., Rutten, M. C. M., Pighi, M., et al. (2020) · EuroIntervention · doi:10.4244/eij-d-19-00879 · Cited by 13
SAVR versus TAVI: What about the Hemodynamic Performance? An In Vivo and In Vitro Analysis
Rahmanian, P. B., Eghbalzadeh, K., Giese, D., Kuhn, E. W., Djordjevic, I., Kaya, S. Y., Weber, C., Baldus, S. E., Mader, N., & Wahlers, T. (2019) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0039-1695779 · Cited by 13
Overtchouk, P., Prendergast, B., & Modine, T. (2019) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2019.03.004 · Cited by 13
Ferrara, J., Deharo, P., Resseguier, N., Porto, A., Jaussaud, N., Morera, P., Amanatiou, C., Gariboldi, V., Collart, F., Cuisset, T., et al. (2021) · Journal of Cardiac Surgery · doi:10.1111/jocs.15483 · Cited by 13
Gozdek, M., Ratajczak, J. M., Arndt, A., Zieliński, K., Pasierski, M., Matteucci, M., Fina, D., Jiritano, F., Meani, P., Raffa, G. M., et al. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.12.107 · Cited by 12
Senguttuvan, N. B., Bhatt, H., Balakrishnan, V. K., Krishnamoorthy, P. M., Goel, S., Reddy, P. M. K., Subramanian, V., Claessen, B. E. P. M., Kumar, A., Majmundar, M. M., et al. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1130354 · Cited by 12
Kooistra, N. H. M., Abawi, M., Voskuil, M., Urgel, K., Samim, M., Nijhoff, F., Nathoe, H. M., Doevendans, P. A., Chamuleau, S. A. J., Leenders, G. E. H., et al. (2020) · Netherlands Heart Journal · doi:10.1007/s12471-020-01414-0 · Cited by 12
Doenst, T., Strüning, C., Moschovas, A., Gonzalez-Lopez, D., Essa, Y., Kirov, H., Diab, M., & Färber, G. (2016) · Clinical Research in Cardiology · doi:10.1007/s00392-016-1013-x · Cited by 12
Metadata
- Authors
- Kodali, S., Pibarot, P., Douglas, P. S., Williams, M., Xu, K., Thourani, V., Rihal, C. S., Zajarias, A., Doshi, D., Davidson, M., Tuzcu, E. M., Stewart, W., Weissman, N. J., Svensson, L., Greason, K., Maniar, H., Mack, M., Anwaruddin, S., Leon, M. B., & Hahn, R. T.
- Affiliations
- NewYork–Presbyterian Hospital (US)
- Duke Clinical Research Institute (US)
- Cardiovascular Research Foundation (US)
- Emory University (US)
- Mayo Clinic (US)
- Brigham and Women's Hospital (US)
- Cleveland Clinic (US)
- MedStar Health Research Institute (US)
- Washington University in St. Louis (US)
- Hospital of the University of Pennsylvania (US)
- Corresponding author
- Kodali, S.
- ORCID
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-10-01
- Volume
- 36
- Issue
- 7
- Pages
- 449-456
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2081463532
- Cited by
- 446
- References
- 40
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 17 · 2023: 29 · 2022: 33 · 2021: 31 · 2020: 48 · 2019: 45 · 2018: 49 · 2017: 67 · 2016: 60 · 2015: 31 · 2014: 3
- FWCI
- 36.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- Corpus Université Laval (Université Laval) (submittedVersion)
- Funders
- Edwards Lifesciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- paravalvular leak, transcatheter aortic valve implantation, Edwards SAPIEN valve, PARTNER trial, aortic stenosis, mortality, left ventricular mass, ventricular geometry, hospital readmission, stroke, echocardiographic assessment, risk stratification, transcatheter versus surgical aortic valve replacement, left ventricular function
- MeSH terms
- Aged, 80 and over, Aortic Valve Insufficiency, Aortic Valve Stenosis, Echocardiography, Female, Humans, Male, Mitral Valve Insufficiency, Organ Size, Reoperation, Heart Valve Prolapse, Treatment Outcome, Transcatheter Aortic Valve Replacement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.