Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
AIM: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) remains uncertain. In this analysis, we sought to evaluate the impact of varying degrees of PVR on both mortality and changes in ventricular geometry and function. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent TAVR from the randomized cohorts and continued access registries in the PARTNER trial were analysed after stratifying by severity of post-implant PVR, which was graded as none/trace in 52.9% (n = 1288), mild in 38.0% (n = 925), and moderate/severe in 9.1% (n = 221). There were significant differences in baseline clinical and echocardiographic characteristics. After TAVR, all the patients demonstrated increase in left ventricular (LV) function and reduction in the LV mass index, although the magnitude of mass regression was lower in the moderate/severe PVR group. The 30-day mortality (3.1 vs. 3.4 vs. 4.5%, P = 0.56) and stroke (3.4 vs. 3.7 vs. 2.3%, P = 0.59) were similar in all groups (none/trace, mild, and moderate/severe). At 1 year, there was increased all-cause mortality (15.9 vs. 22.2 vs. 35.1%, P < 0.0001), cardiac mortality (6.1 vs. 7.4% vs. 16.3%, P < 0.0001) and re-hospitalization (14.4 vs. 23.0 vs. 31.3%, P < 0.0001) with worsening PVR. A multivariable analysis indicated that the presence of moderate/severe PVR (HR: 2.18, 95% CI: 1.57-3.02, P < 0.0001) or mild PVR (HR: 1.37, 95% CI: 1.14-1.90, P = 0.012) was associated with higher late mortality. CONCLUSION: Differences in baseline characteristics in patients with increasing severities of PVR may increase the risk of this complication. Despite these differences, multivariable analysis demonstrated that both mild and moderate/severe PVR predicted higher 1-year mortality.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The association between moderate or severe paravalvular aortic regurgitation and increased mortality has been clearly established”
From Calcific aortic stenosis (2016) · cites this paper as [237]
In the citing paper
“with some studies even suggesting that this adverse association extends to mild regurgitation235;237;238.”
From Calcific aortic stenosis (2016) · cites this paper as [237]
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationZoghbi, W. A., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Kraft, C. D., Levine, R. A., Nihoyannopoulos, P., Otto, C. M., Quinones, M. A., Rakowski, H., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00335-3 · Cited by 4,044
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationUpdated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citationTamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Moat, N. E., Ludman, P., de Belder, M. A., Bridgewater, B., Cunningham, A. D., Young, C. P., Thomas, M., Kovac, J., Spyt, T., MacCarthy, P. A., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.050 · Cited by 884
Research works printed but not linked: 1
- 2012, New England Journal of Medicine, 366, 1686, 10.1056/nejmoa1200384 · DOI · Paper page
Cited by
Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citation2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Thourani, V. H., Kodali, S., Makkar, R. R., Herrmann, H. C., Williams, M., Babaliaros, V., Smalling, R., Lim, S., Malaisrie, S. C., Kapadia, S., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30073-3 · Cited by 1,028
Self-citationLindman, B. R., Clavel, M.-A., Mathieu, P., Iung, B., Lancellotti, P., Otto, C. M., & Pibarot, P. (2016) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2016.6 · Cited by 982
Five-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement
Makkar, R. R., Thourani, V. H., Mack, M. J., Kodali, S. K., Kapadia, S., Webb, J. G., Yoon, S.-H., Trento, A., Svensson, L. G., Herrmann, H. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1910555 · Cited by 832
Self-citationYoon, S.-H., Bleiziffer, S., De Backer, O., Delgado, V., Arai, T., Ziegelmueller, J., Barbanti, M., Sharma, R., Perlman, G. Y., Khalique, O. K., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.017 · Cited by 489
Self-citationZoghbi, W. A., Asch, F. M., Bruce, C., Gillam, L. D., Grayburn, P. A., Hahn, R. T., Inglessis, I., Islam, A. M., Lerakis, S., Little, S. H., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.01.003 · Cited by 439
Self-citationDeeb, G. M., Reardon, M. J., Chetcuti, S., Patel, H. J., Grossman, P. M., Yakubov, S. J., Kleiman, N. S., Coselli, J. S., Gleason, T. G., Lee, J. S., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.03.506 · Cited by 352
Kodali, S., Thourani, V. H., White, J., Malaisrie, S. C., Lim, S., Greason, K. L., Williams, M., Guerrero, M., Eisenhauer, A. C., Kapadia, S., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw112 · Cited by 352
Self-citationBicuspid Aortic Valve Morphology and Outcomes After Transcatheter Aortic Valve Replacement
Yoon, S.-H., Kim, W.-K., Dhoble, A., Milhorini Pio, S., Babaliaros, V., Jilaihawi, H., Pilgrim, T., De Backer, O., Bleiziffer, S., Vincent, F., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.07.005 · Cited by 295
Self-citationAssessment of Paravalvular Regurgitation Following TAVR
Pibarot, P., Hahn, R. T., Weissman, N. J., & Monaghan, M. J. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.01.008 · Cited by 277
Self-citationThiele, H., Kurz, T., Feistritzer, H.-J., Stachel, G., Hartung, P., Eitel, I., Marquetand, C., Nef, H., Doerr, O., Lauten, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa036 · Cited by 262
Yoon, S.-H., Lefèvre, T., Ahn, J.-M., Perlman, G. Y., Dvir, D., Latib, A., Barbanti, M., Deuschl, F., De Backer, O., Blanke, P., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.06.041 · Cited by 227
Self-citationPibarot, P., Hahn, R. T., Weissman, N. J., Arsenault, M., Beaudoin, J., Bernier, M., Dahou, A., Khalique, O. K., Asch, F. M., Toubal, O., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3425 · Cited by 222
Self-citationForrest, J. K., Mangi, A. A., Popma, J. J., Khabbaz, K., Reardon, M. J., Kleiman, N. S., Yakubov, S. J., Watson, D., Kodali, S., George, I., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.10.014 · Cited by 185
Self-citationHerrmann, H. C., Thourani, V. H., Kodali, S. K., Makkar, R. R., Szeto, W. Y., Anwaruddin, S., Desai, N., Lim, S., Malaisrie, S. C., Kereiakes, D. J., et al. (2016) · Circulation · doi:10.1161/circulationaha.116.022797 · Cited by 183
Self-citationTranscatheter Treatment of Valvular Heart Disease: A Review
Davidson, L. J., & Davidson, C. J. (2021) · JAMA · doi:10.1001/jama.2021.2133 · Cited by 181
Popma, J. J., Reardon, M. J., Khabbaz, K., Harrison, J. K., Hughes, G. C., Kodali, S., George, I., Deeb, G. M., Chetcuti, S., Kipperman, R., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.08.050 · Cited by 180
Self-citationVan Belle, E., Vincent, F., Labreuche, J., Auffret, V., Debry, N., Lefèvre, T., Eltchaninoff, H., Manigold, T., Gilard, M., Verhoye, J.-P., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.043785 · Cited by 171
Feldman, T. E., Reardon, M. J., Rajagopal, V., Makkar, R. R., Bajwa, T. K., Kleiman, N. S., Linke, A., Kereiakes, D. J., Waksman, R., Thourani, V. H., et al. (2018) · JAMA · doi:10.1001/jama.2017.19132 · Cited by 168
Self-citationPîbarot, P., Salaün, E., Dahou, A., Avenatti, E., Guzzetti, E., Annabi, M., Toubal, O., Bernier, M., Beaudoin, J., Ong, G., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.044574 · Cited by 160
Self-citationVon Willebrand Factor Multimers during Transcatheter Aortic-Valve Replacement
Van Belle, E., Rauch, A., Vincent, F., Robin, E., Kibler, M., Labreuche, J., Jeanpierre, E., Levade, M., Hurt, C., Rousse, N., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1505643 · Cited by 159
Duncan, A., Ludman, P., BANYA, W. A. S., Cunningham, D., Marlee, D., Davies, S., Mullen, M., Kovac, J., Spyt, T. J., & Moat, N. E. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.01.009 · Cited by 154
Transcatheter Aortic Valve Replacement 2016
Vahl, T. P., Kodali, S., & Leon, M. B. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.12.059 · Cited by 149
Self-citationOutcomes Following Urgent/Emergent Transcatheter Aortic Valve Replacement
Kolte, D., Khera, S., Vemulapalli, S., Dai, D., Heo, S., Goldsweig, A. M., Aronow, H. D., Elmariah, S., Inglessis, I., Palacios, I. F., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.03.002 · Cited by 140
Self-citationKodali, S., Williams, M. R., Doshi, D., Hahn, R. T., Humphries, K. H., Nkomo, V. T., Cohen, D. J., Douglas, P. S., Mack, M., Xu, K., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-0121 · Cited by 138
Self-citationOkuno, T., Asami, M., Heg, D., Lanz, J., Praz, F., Hagemeyer, D., Brugger, N., Gräni, C., Huber, A. T., Spirito, A., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.04.015 · Cited by 131
Meredith, I. T., Walters, D., Dumonteil, N., Worthley, S. G., Tchétché, D., Manoharan, G., Blackman, D. J., Rioufol, G., Hildick‐Smith, D., Whitbourn, R., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.10.024 · Cited by 129
Management strategies and future challenges for aortic valve disease
Bonow, R. O., Leon, M. B., Doshi, D., & Moat, N. E. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00586-9 · Cited by 128
Self-citationSá, M. P., Jacquemyn, X., den Eynde, J. V., Tasoudis, P., Erten, O., Sicouri, S., Macedo, F., Pasala, T. K. R., Kaple, R., Weymann, A., et al. (2022) · Structural Heart · doi:10.1016/j.shj.2022.100118 · Cited by 125
Five-year outcomes of mild paravalvular regurgitation after transcatheter aortic valve implantation
Okuno, T., Tomii, D., Heg, D., Lanz, J., Praz, F., Stortecky, S., Reineke, D., Windecker, S., & Pilgrim, T. (2022) · EuroIntervention · doi:10.4244/eij-d-21-00784 · Cited by 125
Mauri, V., Kim, W. K., Abumayyaleh, M., Walther, T., Moellmann, H., Schäfer, U., Conradi, L., Hengstenberg, C., Hilker, M., Wahlers, T., et al. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.117.005013 · Cited by 123
Webb, J. G., Doshi, D., Mack, M. J., Makkar, R., Smith, C. R., Pichard, A. D., Kodali, S., Kapadia, S. R., Miller, D. C., Babaliaros, V. C., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.08.017 · Cited by 111
Self-citationMulticenter Comparison of Novel Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves
Hüsser, O., Kim, W., Pellegrini, C., Holzamer, A., Walther, T., Mayr, N. P., Joner, M., Kasel, A. M., Trenkwalder, T., Michel, J., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.06.026 · Cited by 111
Transcatheter Aortic Valve Replacement: Comprehensive Review and Present Status
Arora, S., Misenheimer, J. A., & Ramaraj, R. (2017) · Texas Heart Institute Journal · doi:10.14503/thij-16-5852 · Cited by 110
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Cuartas, M. M., Abreu, A., Adamo, M., Marsan, N. A., Barili, F., Bonaros, N. E., Cosyns, B., et al. (2025) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezaf276 · Cited by 107
Seiffert, M., Fujita, B., Avanesov, M., Lunau, C., Schön, G., Conradi, L., Prashovikj, E., Scholtz, S., Börgermann, J., Scholtz, W., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jev174 · Cited by 106
Takagi, H., & Umemoto, T. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.07.006 · Cited by 105
Oh, J. K., Little, S. H., Abdelmoneim, S. S., Reardon, M. J., Kleiman, N. S., Lin, G., Bach, D. S., Gillam, L. D., Kar, B., Coselli, J. S., et al. (2015) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2015.07.012 · Cited by 101
Sato, K., Kumar, A., Jones, B., Mick, S. L., Krishnaswamy, A., Grimm, R. A., Desai, M. Y., Griffin, B. P., Rodriguez, L. L., Kapadia, S. R., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.005798 · Cited by 95
Russo, G., Tang, G. H. L., Sangiorgi, G., Pedicino, D., Enriquez-Sarano, M. L., Maisano, F., & Taramasso, M. (2022) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.122.012388 · Cited by 94
Transcatheter aortic valve replacement (TAVR): Recent updates
Avvedimento, M., & Tang, G. H. L. (2021) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2021.11.003 · Cited by 92
Longitudinal Hemodynamics of Transcatheter and Surgical Aortic Valves in the PARTNER Trial
Douglas, P. S., Leon, M. B., Mack, M. J., Svensson, L. G., Webb, J. G., Hahn, R. T., Pîbarot, P., Weissman, N. J., Miller, D. C., Kapadia, S. R., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3306 · Cited by 89
Self-citationLaakso, T., Laine, M., Moriyama, N., Dahlbacka, S., Airaksinen, J. K. E., Virtanen, M. P. O., Husso, A., Tauriainen, T., Niemelä, M. J., Mäkikallio, T. H., et al. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezaa254 · Cited by 88
Hellhammer, K., Piayda, K., Afzal, S., Kleinebrecht, L., Makosch, M., Hennig, I., Quast, C., Jung, C., Polzin, A., Westenfeld, R., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.07.023 · Cited by 87
Renin–angiotensin system blockade therapy after transcatheter aortic valve implantation
Ochiai, T., Saito, S., Yamanaka, F., Shishido, K., Tanaka, Y., Yamabe, T., Shirai, S., Tada, N., Araki, M., Naganuma, T., et al. (2018) · Heart · doi:10.1136/heartjnl-2017-311738 · Cited by 84
Transcatheter Aortic Valve Replacement With Next-Generation Self-Expanding Devices
Pagnesi, M., Kim, W.-K., Conradi, L., Barbanti, M., Stefanini, G. G., Zeus, T., Pilgrim, T., Schöfer, J., Zweiker, D., Testa, L., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.11.036 · Cited by 81
Dowling, C., Bavo, A. M., Faquir, N. E., Mortier, P., de Jaegere, P. P. T., Backer, O. D., Søndergaard, L., Ruile, P., Mylotte, D., McConkey, H. Z. R., et al. (2019) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.119.009178 · Cited by 79
Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review
Claessen, B. E. P. M., Tang, G. H. L., Kini, A. S., & Sharma, S. K. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2020.3682 · Cited by 78
Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves
Rheude, T. A., Pellegrini, C., Lutz, J., Alvarez‐Covarrubias, H. A., Lahmann, A. L., Mayr, N. P., Michel, J., Kasel, A. M., Joner, M., & Xhepa, E. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.07.013 · Cited by 75
Zhou, D., Pan, W., Wang, J., Wu, Y., Chen, M., Modine, T., Mylotte, D., Piazza, N., & Ge, J. (2019) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28226 · Cited by 75
Falk, V., Wöhrle, J., Hildick‐Smith, D., Bleiziffer, S., Blackman, D. J., Abdel‐Wahab, M., Gerckens, U. J., Linke, A. H.-P., İnce, H., Wenaweser, P., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx297 · Cited by 74
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Cuartas, M. M., Abreu, A., Adamo, M., Marsan, N. A., Barili, F., Bonaros, N. E., Cosyns, B., et al. (2025) · European Heart Journal - Valvular and Structural Heart Disease · doi:10.1093/ehjvshd/xwag001 · Cited by 71
Ando, T., Briasoulis, Α., Telila, T. A., Afonso, L., Grines, C. L., & Takagi, H. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27336 · Cited by 71
Nijhoff, F., Abawi, M., Agostoni, P., Ramjankhan, F. Z., Doevendans, P. A., & Stella, P. R. (2015) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.115.002408 · Cited by 71
The transcatheter valve technology pipeline for treatment of adult valvular heart disease
Figulla, H. R., Webb, J. G., Lauten, A., & Feldman, T. E. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw153 · Cited by 64
Echocardiographic Imaging for Transcatheter Aortic Valve Replacement
Hahn, R. T., Nicoara, A., Kapadia, S. R., Svensson, L. G., & Martin, R. P. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.10.022 · Cited by 64
Self-citationSorajja, P., Kodali, S., Reardon, M. J., Szeto, W. Y., Chetcuti, S. J., Hermiller, J. B., Chenoweth, S., Adams, D. H., & Popma, J. J. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.07.027 · Cited by 63
Self-citationA 20-year journey in transcatheter aortic valve implantation: Evolution to current eminence
Kalogeropoulos, A. S., Redwood, S. R., Allen, C. J., Hurrell, H., Chehab, O., Rajani, R., Prendergast, B., & Patterson, T. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.971762 · Cited by 61
Rogers, T., Steinvil, A., Gai, J., Torguson, R., Koifman, E., Kiramijyan, S., Negi, S., Lee, S. Y., Okubagzi, P. G., Satler, L. F., et al. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2016.11.044 · Cited by 59
Dowling, C., Firoozi, S., & Brecker, S. J. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.07.032 · Cited by 59
Jones, B., Tuzcu, E. M., Krishnaswamy, A., Popović, Z., Mick, S., Roselli, E. E., Gul, S., Devgun, J. K., Mistry, S., Jaber, W. A., et al. (2016) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2016.05.023 · Cited by 57
Self-citationTissue-Engineered Heart Valves: A Call for Mechanistic Studies
Blum, K. M., Drews, J. D., & Breuer, C. K. (2018) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2017.0425 · Cited by 56
Rogers, T., Steinvil, A., Buchanan, K. D., Alraies, M. C., Koifman, E., Gai, J., Torguson, R., Okubagzi, P. G., Ben‐Dor, I., Pichard, A. D., et al. (2017) · Journal of Interventional Cardiology · doi:10.1111/joic.12389 · Cited by 56
Nazif, T. M., Cahill, T. J., Daniels, D. V., McCabe, J. M., Reisman, M., Chakravarty, T., Makkar, R., Krishnaswamy, A., Kapadia, S. R., Chehab, B., et al. (2021) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.121.010543 · Cited by 55
Self-citationHüsser, O., Pellegrini, C., Kessler, T., Burgdorf, C., Thaller, H., Mayr, N. P., Ott, I., Kasel, A. M., Schunkert, H., Kastrati, A., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.08.014 · Cited by 55
Chau, K. C., Chen, S., Crowley, A., Redfors, B., Li, D., Hahn, R. H., Douglas, P. S., Alu, M. C., Finn, M. F., Kodali, S., et al. (2022) · EuroIntervention · doi:10.4244/eij-d-20-01293 · Cited by 54
Self-citationFrom CoreValve to Evolut PRO: Reviewing the Journey of Self-Expanding Transcatheter Aortic Valves
Mahtta, D., Elgendy, I. Y., & Bavry, A. A. (2017) · Cardiology and Therapy · doi:10.1007/s40119-017-0100-z · Cited by 54
Abdel‐Wahab, M., Abdelghani, M., Miyazaki, Y., Holy, E. W., Merten, C., Zachow, D., Tonino, P. A. L., Rutten, M. C. M., van de Vosse, F. N., Morel, M., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.08.045 · Cited by 54
Mauri, V., Deuschl, F. G., Frohn, T., Schofer, N., Linder, M., Kuhn, E. W., Schaefer, A., Rudolph, V., Madershahian, N., Conradi, L., et al. (2018) · Clinical Research in Cardiology · doi:10.1007/s00392-018-1235-1 · Cited by 53
Adjudicating paravalvular leaks of transcatheter aortic valves: a critical appraisal
Abdelghani, M., Soliman, O. I. I., Schultz, C. J., Vahanian, A. S., & Serruys, P. W. J. C. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw115 · Cited by 52
Raschpichler, M., de Waha, S., Holzhey, D. M., Schwarzer, G., Flint, N., Kaewkes, D., Bräuchle, P. T., Dvir, D., Makkar, R., Ailawadi, G., et al. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.024848 · Cited by 50
Liao, Y., Li, Y., Xiong, T., Ou, Y., Lv, W., He, J., Li, Y., Zhao, Z., Wei, X., Xu, Y., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.12.013 · Cited by 50
Ngo, A., Hassager, C., Thyregod, H. G. H., Søndergaard, L., Olsen, P. S., Steinbrüchel, D. A., Hansen, P. B., Kjærgaard, J., Winther‐Jensen, M., & Ihlemann, N. (2017) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew321 · Cited by 50
Wöhrle, J., Gonska, B., Rodewald, C., Trepte, U., Koch, S., Scharnbeck, D., Seeger, J., Markovic, S., & Rottbauer, W. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.05.139 · Cited by 50
Hansson, N. C., Leipsic, J. A., Pugliese, F., Andersen, H., Rossi, A., Simonato, M., Jensen, K. T., Christiansen, E. H., Terkelsen, C. J., Blanke, P., et al. (2018) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2018.02.002 · Cited by 48
Sá, M. P., Simonato, M., den Eynde, J. V., Cavalcanti, L. R. P., Alsagheir, A., Tzani, A. I., Fovino, L. N., Kampaktsis, P. Ν., Gallo, M., Laforgia, P. L., et al. (2021) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.29538 · Cited by 48
Sinning, J., Stundl, A., Pingel, S., Weber, M., Sedaghat, A., Hammerstingl, C., Vasa‐Nicotera, M., Mellert, F., Schiller, W., Kovac, J., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.12.271 · Cited by 47
Heart failure: the cardiovascular epidemic of the 21st century
Lüscher, T. F. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv004 · Cited by 47
Assessment of Prosthetic Valve Function After TAVR
Pislaru, S. V., Nkomo, V. T., & Sandhu, G. S. (2016) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2015.11.010 · Cited by 46
Harrison, J. K., Hughes, G. C., Reardon, M. J., Stoler, R., Grayburn, P. A., Hebeler, R. F., Liu, D., Chang, Y., & Popma, J. J. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.11.002 · Cited by 46
Keshavarz‐Motamed, Z., Khodaei, S., Nezami, F. R., Amrute, J., Lee, S. J., Brown, J. Y., Ben–Assa, E., Camarero, T. G., Calvo, J. R., Sellers, S., et al. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.015063 · Cited by 46
Bettinger, N., Khalique, O. K., Krepp, J. M., Hamid, N. B., Bae, D. J., Pulerwitz, T., Liao, M., Hahn, R. T., Vahl, T. P., Nazif, T. M., et al. (2017) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2017.04.009 · Cited by 44
Self-citationHayek, S. S., Corrigan, F. E., Condado, J. F., Lin, S., Howell, S., MacNamara, J. P., Zheng, S., Keegan, P., Thourani, V. H., Babaliaros, V. C., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.02.002 · Cited by 44
Self-citationMauri, V., Frohn, T., Deuschl, F. G., Mohemed, K., Kuhr, K., Reimann, A., Körber, M. I., Schofer, N., Adam, M., Friedrichs, K. P., et al. (2020) · Open Heart · doi:10.1136/openhrt-2019-001164 · Cited by 44
Shahim, B., Redfors, B., Lindman, B. R., Chen, S., Dahlén, T., Nazif, T. M., Kapadia, S. R., Gertz, Z. M., Crowley, A., Li, D., et al. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.024091 · Cited by 44
Self-citationLandes, U., Hochstadt, A., Manevich, L., Webb, J. G., Sathananthan, J., Sievert, H., Piayda, K., Leon, M. B., Nazif, T. M., Blusztein, D. I., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad146 · Cited by 43
Self-citationLanz, J., Möllmann, H., Kim, W., Burgdorf, C., Linke, A. H.-P., Redwood, S. R., Hilker, M., Joner, M., Thiele, H., Conzelmann, L. O., et al. (2023) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.123.012873 · Cited by 43
Giannini, C., Carlo, M. D., Tamburino, C., Ettori, F., Latib, A., Bedogni, F., Bruschi, G., Presbitero, P., Poli, A., Fabbiocchi, F., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.05.095 · Cited by 43
Baggio, S., Pagnesi, M., Kim, W., Scotti, A., Barbanti, M., Costa, G., Adamo, M., Kornowski, R., Assa, H. V., Estévez‐Loureiro, R., et al. (2023) · EuroIntervention · doi:10.4244/eij-d-22-00498 · Cited by 41
Salizzoni, S., D’Onofrio, A., Agrifoglio, M., Colombo, A., Chieffo, A., Cioni, M., Besola, L., Regesta, T., Rapetto, F., Tarantini, G., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw218 · Cited by 41
Carnero, M., Maroto, L. C., Cobiella-Carnicer, J., Vilacosta, I., y, L. N.-F., Alswies, A., Villagrán-Medinilla, E., & Macaya, C. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw388 · Cited by 40
Goel, H., Kumar, A., Garg, N., & Mills, J. D. (2019) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2019.11.010 · Cited by 38
van Wely, M., Rooijakkers, M. J. P., Stens, N. A., Messaoudi, S. E., Somers, T., van Garsse, L. A. F. M., Thijssen, D. H. J., Nijveldt, R., & van Royen, N. (2024) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyae040 · Cited by 38
Outcomes of three different new generation transcatheter aortic valve prostheses
Costa, G., Buccheri, S., Barbanti, M., Picci, A., Todaro, D., Simone, E. D., Spina, K. L., D'Arrigo, P., Criscione, E., Nastasi, M., et al. (2019) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.28524 · Cited by 38
Abdelghani, M., Tateishi, H., Miyazaki, Y., Cavalcante, R., Soliman, O. I. I., Tijssen, J. G. P., de Winter, R. J., Baan, J., Onuma, Y., Campos, C. M., et al. (2017) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26926 · Cited by 38
Massoullié, G., Ploux, S., Souteyrand, G., Mondoly, P., Pereira, B., Amabile, N., Jean, F., Irles, D., Mansourati, J., Combaret, N., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.01.013 · Cited by 38
Transcatheter aortic valve implantation for mixed versus pure stenotic aortic valve disease
Abdelghani, M., Cavalcante, R., Miyazaki, Y., de Winter, R. J., Tijssen, J. G. P., Sarmento‐Leite, R., Mangione, J. A., Abizaid, A., Lemos, P. A., Serruys, P. W. J. C., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-17-00328 · Cited by 37
Kalogeras, K. I., Ruparelia, N., Kabir, T., Jabbour, R. J., Naganuma, T., Vavuranakis, M., Nakamura, S., Wang, B., Sen, S., Hadjiloizou, N., et al. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.02.070 · Cited by 37
Quantitative Assessment of Acute Regurgitation Following TAVR
Modolo, R., Chang, C. C., Abdelghani, M., Kawashima, H., Ono, M., Tateishi, H., Miyazaki, Y., Pighi, M., Wykrzykowska, J. J., de Winter, R. J., et al. (2020) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2020.03.002 · Cited by 36
Metadata
- Authors
- Kodali, S., Pibarot, P., Douglas, P. S., Williams, M., Xu, K., Thourani, V., Rihal, C. S., Zajarias, A., Doshi, D., Davidson, M., Tuzcu, E. M., Stewart, W., Weissman, N. J., Svensson, L., Greason, K., Maniar, H., Mack, M., Anwaruddin, S., Leon, M. B., & Hahn, R. T.
- Affiliations
- NewYork–Presbyterian Hospital (US)
- Duke Clinical Research Institute (US)
- Cardiovascular Research Foundation (US)
- Emory University (US)
- Mayo Clinic (US)
- Brigham and Women's Hospital (US)
- Cleveland Clinic (US)
- MedStar Health Research Institute (US)
- Washington University in St. Louis (US)
- Hospital of the University of Pennsylvania (US)
- Corresponding author
- Kodali, S.
- ORCID
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-10-01
- Volume
- 36
- Issue
- 7
- Pages
- 449-456
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2081463532
- Cited by
- 446
- References
- 40
- Citations by year
- 2026: 14 · 2025: 18 · 2024: 17 · 2023: 29 · 2022: 33 · 2021: 31 · 2020: 48 · 2019: 45 · 2018: 49 · 2017: 67 · 2016: 60 · 2015: 31 · 2014: 3
- FWCI
- 36.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- Corpus Université Laval (Université Laval) (submittedVersion)
- Funders
- Edwards Lifesciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Keywords
- paravalvular leak, transcatheter aortic valve implantation, Edwards SAPIEN valve, PARTNER trial, aortic stenosis, mortality, left ventricular mass, ventricular geometry, hospital readmission, stroke, echocardiographic assessment, risk stratification, transcatheter versus surgical aortic valve replacement, left ventricular function
- MeSH terms
- Aged, 80 and over, Aortic Valve Insufficiency, Aortic Valve Stenosis, Echocardiography, Female, Humans, Male, Mitral Valve Insufficiency, Organ Size, Reoperation, Heart Valve Prolapse, Treatment Outcome, Transcatheter Aortic Valve Replacement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.