BACKGROUND: In at-risk patients with left ventricular dysfunction, implantable cardioverter defibrillators (ICDs) prolong life. Implantable cardioverter defibrillators are increasingly implanted for primary prevention and therefore into lower risk patients. Trial data have demonstrated the benefit of these devices but does not provide an estimate of potential lifespan-gain over longer time periods, e.g. a patient's lifespan. METHODS: Using data from landmark ICD trials, lifespan-gain was plotted against baseline annual mortality in the individual trials. Lifespan-gain was then extrapolated to a time-horizon of >20 years while adjusting for increasing 'competing' risk from ageing and non-sudden cardiac death (pump failure). RESULTS: At 3 years, directly observed lifespan-gain was strongly dependent on baseline event rate (r = 0.94, P < 0.001). However, projecting beyond the duration of the trial, lifespan-gain increases rapidly and non-linearly with time. At 3 years, it averages 1.7 months, but by 10 years up to 9-fold more. Lifespan-gain over time horizons >20 years were greatest in lower risk patients (∼5 life-years for 5% baseline mortality, ∼2 life-years for 15% baseline mortality). Increased competing risks significantly reduce lifespan-gain from ICD implantation. CONCLUSION: While high-risk patients may show the greatest short-term gain, the dramatic growth of lifespan-gain over time means that it is the lower risk patients, e.g. primary prevention ICD implantation, who gain the most life-years over their lifetime. Benefit is underestimated when only trial data are assessed as trials can only maintain randomization over limited periods. Lifespan-gain may be further increased through advances in ICD device programming.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehv102

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 37

Metadata

Authors
Raphael, C. E., Finegold, J. A., Barron, A. J., Whinnett, Z. I., Mayet, J., Linde, C., Cleland, J. G. F., Levy, W. C., & Francis, D. P.
Venue
European Heart Journal
Published
2015-04-23
Volume
36
Issue
26
Pages
1676-1688
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2166679677
Cited by
37
References
5
FWCI
4.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of duration of follow-up and presence of competing risk on lifespan-gain from implantable cardioverter defibrillator therapy: who benefits the most? https://app.cochat.ai/papers/10.1093/eurheartj/ehv102
The paper
Raphael, C. E., Finegold, J. A., Barron, A. J., Whinnett, Z. I., Mayet, J., Linde, C., Cleland, J. G. F., Levy, W. C., & Francis, D. P. (2015). The effect of duration of follow-up and presence of competing risk on lifespan-gain from implantable cardioverter defibrillator therapy: who benefits the most? European Heart Journal. https://doi.org/10.1093/eurheartj/ehv102

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.