Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
AIMS: We sought to evaluate the frequency of early hypo-attenuated leaflet thickening (HALT) of the SAPIEN 3 transcatheter aortic valve (S3). METHODS AND RESULTS: Of 249 patients who had undergone S3 implantation, we studied 156 consecutive patients (85 women, median age 82.2 ± 5.5 years) by electrocardiogram (ECG)-triggered dual-source computed tomography angiography (CTA) after a median of 5 days post-transcatheter aortic valve implantation. The prosthesis was assessed for HALT. Apart from heparin, peri-interventional antithrombotic therapy consisted of single- (aspirin 29%) or dual- (aspirin plus clopidogrel 71%) antiplatelet therapy. Hypo-attenuated leaflet thickening was found in 16 patients [10.3% (95% confidence interval (CI) 5.5-15.0%)] of the patients. None of the baseline and procedural variables were significantly associated with HALT, nor did we find a significant association with the antithrombotic regimen, either peri-interventionally or at the time of CTA. Hypo-attenuated leaflet thickening was found in 6 of 45 patients with peri-interventional single-antiplatelet therapy and in 10 of 111 patients with dual-antiplatelet therapy at the time of intervention [13.3% (95% CI 3.4-23.3%) vs. 9% (95% CI 3.7-14.3%), P = 0.42]. Hypo-attenuated leaflet thickening was not associated with clinical symptoms, but a small, albeit significant difference in mean pressure gradient at the time of CTA (11.6 ± 3.4 vs. 14.9 ± 5.3 mmHg, P = 0.026). Full anticoagulation led to almost complete resolution of HALT in 13 patients with follow-up CTA. CONCLUSION: Irrespective of the antiplatelet regimen, early HALT occurred in 10% of our patients undergoing transcatheter aortic S3 implantation. Early HALT is clinically inapparent and reversible by full anticoagulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs455 · Cited by 2,009
Dewilde, W. J., Oirbans, T., Verheugt, F. W., Kelder, J. C., De Smet, B. J., Herrman, J.-P., Adriaenssens, T., Vrolix, M., Heestermans, A. A., Vis, M. M., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)62177-1 · Cited by 1,719
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 900
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Thrombosis of prosthetic heart valves: diagnosis and therapeutic considerations
Roudaut, R., Serri, K., & Lafitte, S. (2007) · Heart · doi:10.1136/hrt.2005.071183 · Cited by 479
Hochholzer, W., Trenk, D., Fromm, M. F., Valina, C. M., Stratz, C., Bestehorn, H.-P., Büttner, H. J., & Neumann, F.-J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.02.031 · Cited by 320
Self-citationMulticenter Evaluation of a Next-Generation Balloon-Expandable Transcatheter Aortic Valve
Webb, J., Gerosa, G., Lefèvre, T., Leipsic, J., Spence, M., Thomas, M., Thielmann, M., Treede, H., Wendler, O., & Walther, T. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.026 · Cited by 313
Self-citationTreatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis
Latib, A., Naganuma, T., Abdel-Wahab, M., Danenberg, H., Cota, L., Barbanti, M., Baumgartner, H., Finkelstein, A., Legrand, V., de Lezo, J. S., et al. (2015) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.114.001779 · Cited by 293
Warfarin Anticoagulation and Outcomes in Patients With Atrial Fibrillation
Reynolds, M. W., Fahrbach, K., Hauch, O., Wygant, G., Estok, R., Cella, C., & Nalysnyk, L. (2004) · Chest · doi:10.1378/chest.126.6.1938 · Cited by 262
Cited by
2017 ESC/EACTS Guidelines for the management of valvular heart disease
Baumgartner, H., Falk, V., Bax, J. J., De Bonis, M., Hamm, C., Holm, P. J., Iung, B., Lancellotti, P., Lansac, E., Rodriguez Muñoz, D., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx391 · Cited by 6,243
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Fleisher, L. A., Jneid, H., Mack, M. J., McLeod, C. J., O’Gara, P. T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.011 · Cited by 3,339
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Fleisher, L. A., Jneid, H., Mack, M. J., McLeod, C. J., O’Gara, P. T., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000503 · Cited by 2,497
Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citationVARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Self-citationChakravarty, T., Søndergaard, L., Friedman, J., De Backer, O., Berman, D., Kofoed, K. F., Jilaihawi, H., Shiota, T., Abramowitz, Y., Jørgensen, T. H., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30757-2 · Cited by 909
2017 ESC/EACTS Guidelines for the Management of Valvular Heart Disease
Baumgartner, H., Falk, V., Bax, J. J., De Bonis, M., Hamm, C., Holm, P. J., Iung, B., Lancellotti, P., Lansac, E., Muñoz, D. R., et al. (2018) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2017.12.013 · Cited by 672
2017 ESC/EACTS Guidelines for the management of valvular heart disease
Falk, V., Baumgartner, H., Bax, J. J., De Bonis, M., Hamm, C., Holm, P. J., Iung, B., Lancellotti, P., Lansac, E., Muñoz, D. R., et al. (2017) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezx324 · Cited by 630
Blanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Nørgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.12.003 · Cited by 610
Self-citationBlanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Norgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2018.11.008 · Cited by 543
Self-citationCapodanno, D., Petronio, A. S., Prendergast, B., Eltchaninoff, H., Vahanian, A., Modine, T., Lancellotti, P., Sondergaard, L., Ludman, P. F., Tamburino, C., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx303 · Cited by 535
Prosthetic Heart Valve Thrombosis
Dangas, G. D., Weitz, J. I., Giustino, G., Makkar, R., & Mehran, R. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.09.958 · Cited by 502
Dvir, D., Bourguignon, T., Otto, C. M., Hahn, R. T., Rosenhek, R., Webb, J. G., Treede, H., Sarano, M. E., Feldman, T., Wijeysundera, H. C., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030729 · Cited by 479
Self-citationTranscatheter Aortic Valve Thrombosis
Hansson, N. C., Grove, E. L., Andersen, H. R., Leipsic, J., Mathiassen, O. N., Jensen, J. M., Jensen, K. T., Blanke, P., Leetmaa, T., Tang, M., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.08.010 · Cited by 367
Self-citationJCS/JSCS/JATS/JSVS 2020 Guidelines on the Management of Valvular Heart Disease
Izumi, C., Eishi, K., Ashihara, K., Arita, T., Otsuji, Y., Kunihara, T., Komiya, T., Shibata, T., Seo, Y., Daimon, M., et al. (2020) · Circulation Journal · doi:10.1253/circj.cj-20-0135 · Cited by 367
Mechanical versus bioprosthetic aortic valve replacement
Head, S. J., Çelik, M., & Kappetein, A. P. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx141 · Cited by 363
Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical Risk
Leon, M. B., Mack, M. J., Hahn, R. T., Thourani, V. H., Makkar, R., Kodali, S. K., Alu, M. C., Madhavan, M. V., Chau, K. H., Russo, M., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.12.052 · Cited by 325
Self-citationReduced Leaflet Motion after Transcatheter Aortic-Valve Replacement
De Backer, O., Dangas, G. D., Jilaihawi, H., Leipsic, J. A., Terkelsen, C. J., Makkar, R., Kini, A. S., Veien, K. T., Abdel-Wahab, M., Kim, W.-K., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1911426 · Cited by 293
Self-citationClinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement
Jose, J., Sulimov, D. S., El-Mawardy, M., Sato, T., Allali, A., Holy, E. W., Becker, B., Landt, M., Kebernik, J., Schwarz, B., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.01.045 · Cited by 257
Natural history of subclinical leaflet thrombosis affecting motion in bioprosthetic aortic valves
Sondergaard, L., De Backer, O., Kofoed, K. F., Jilaihawi, H., Fuchs, A., Chakravarty, T., Kashif, M., Kazuno, Y., Kawamori, H., Maeno, Y., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx369 · Cited by 227
Systematic CT Methodology for the Evaluation of Subclinical Leaflet Thrombosis
Jilaihawi, H., Asch, F. M., Manasse, E., Ruiz, C. E., Jelnin, V., Kashif, M., Kawamori, H., Maeno, Y., Kazuno, Y., Takahashi, N., et al. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.02.005 · Cited by 201
Zoghbi, W. A., Jone, P.-N., Chamsi-Pasha, M. A., Chen, T., Collins, K. A., Desai, M. Y., Grayburn, P., Groves, D. W., Hahn, R. T., Little, S. H., et al. (2024) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2023.10.004 · Cited by 197
Incidence, Predictors, and Mid-Term Outcomes of Possible Leaflet Thrombosis After TAVR
Yanagisawa, R., Hayashida, K., Yamada, Y., Tanaka, M., Yashima, F., Inohara, T., Arai, T., Kawakami, T., Maekawa, Y., Tsuruta, H., et al. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.11.005 · Cited by 188
Bioprosthetic Valve Thrombosis
Puri, R., Auffret, V., & Rodés-Cabau, J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.051 · Cited by 188
“(51) 101/752 (13) 101/752 (13) 5/138 (4) 5/138 (4) 83 (33-281) 9.”
MethodDetection and Prediction of Bioprosthetic Aortic Valve Degeneration
Cartlidge, T. R. G., Doris, M. K., Sellers, S. L., Pawade, T. A., White, A. C., Pessotto, R., Kwiecinski, J., Fletcher, A., Alcaide, C., Lucatelli, C., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.056 · Cited by 166
Self-citation
Metadata
- Authors
- Pache, G., Schoechlin, S., Blanke, P., Dorfs, S., Jander, N., Arepalli, C. D., Gick, M., Buettner, H.-J., Leipsic, J., Langer, M., Neumann, F.-J., & Ruile, P.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-10-07
- Volume
- 37
- Issue
- 28
- Pages
- 2263-2271
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2254220616
- Cited by
- 292
- References
- 27
- FWCI
- 25.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.