Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 374

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Percutaneous short-term active mechanical support devices in cardiogenic shock: a systematic review and collaborative meta-analysis of randomized trials

Open access
Thiele, Holger, Jobs, Alexander, Ouweneel, Dagmar M, Henriques, Jose P S, Seyfarth, Melchior, Desch, Steffen, Eitel, Ingo, Pöss, Janine, Fuernau, Georg, de Waha, Suzanne·2017·European Heart Journal

Abstract

AIMS: Evidence on the impact on clinical outcome of active mechanical circulatory support (MCS) devices in cardiogenic shock (CS) is scarce. This collaborative meta-analysis of randomized trials thus aims to investigate the efficacy and safety of percutanzeous active MCS vs. control in CS. METHODS AND RESULTS: Randomized trials comparing percutaneous active MCS to control in patients with CS were identified through searches of medical literature databases. Risk ratios (RR) and 95% confidence intervals (95% CI) were calculated to analyse the primary endpoint of 30-day mortality and device-related complications including bleeding and leg ischaemia. Mean differences (MD) were calculated for mean arterial pressure (MAP), cardiac index (CI), pulmonary capillary wedge pressure (PCWP), and arterial lactate. Four trials randomizing 148 patients to either TandemHeart™ or Impella® MCS (n = 77) vs. control (n = 71) were identified. In all four trials intra-aortic balloon pumping (IABP) served as control. There was no difference in 30-day mortality (RR 1.01, 95% CI 0.70 to 1.44, P = 0.98, I2 = 0%) for active MCS compared with control. Active MCS significantly increased MAP (MD 11.85 mmHg, 95% CI 3.39 to 20.31, P = 0.02, I2 = 32.7%) and decreased arterial lactate (MD - 1.36 mmol/L, 95% CI - 2.52 to - 0.19, I2 = 0%, P = 0.02) at comparable CI (MD 0.32, 95% CI - 0.24 to 0.87, P = 0.14, I2 = 44.1%) and PCWP (MD - 5.59, 95% -15.59 to 4.40, P = 0.14, I2 = 81.1%). No significant difference was observed in the incidence of leg ischaemia (RR 2.64, 95% CI 0.83 to 8.39, P = 0.10, I2 = 0%), whereas the rate of bleeding was significantly increased in MCS compared to IABP (RR 2.50, 95% CI 1.55 to 4.04, P < 0.001, I2 = 0%). CONCLUSION: Results of this collaborative meta-analysis do not support the unselected use of active MCS in patients with CS complicating AMI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehx363

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 374

Metadata

Authors
Thiele, H., Jobs, A., Ouweneel, D. M., Henriques, J. P. S., Seyfarth, M., Desch, S., Eitel, I., Pöss, J., Fuernau, G., & de Waha, S.
Venue
European Heart Journal
Published
2017-07-07
Volume
38
Issue
47
Pages
3523-3531
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2728706893
Cited by
374
References
26
FWCI
3.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous short-term active mechanical support devices in cardiogenic shock: a systematic review and collaborative meta-analysis of randomized trials. https://app.cochat.ai/papers/10.1093/eurheartj/ehx363
The paper
Thiele, H., Jobs, A., Ouweneel, D. M., Henriques, J. P. S., Seyfarth, M., Desch, S., Eitel, I., Pöss, J., Fuernau, G., & de Waha, S. (2017). Percutaneous short-term active mechanical support devices in cardiogenic shock: a systematic review and collaborative meta-analysis of randomized trials. European Heart Journal. https://doi.org/10.1093/eurheartj/ehx363

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.