CoChat

Comprehensive evaluation of the effectiveness and safety of balloon pulmonary angioplasty for inoperable chronic thrombo-embolic pulmonary hypertension: long-term effects and procedure-related complications

Aoki, Tatsuo, Sugimura, Koichiro, Tatebe, Shunsuke, Miura, Masanobu, Yamamoto, Saori, Yaoita, Nobuhiro, Suzuki, Hideaki, Sato, Haruka, Kozu, Katsuya, Konno, Ryo, Miyata, Satoshi, Nochioka, Kotaro, Satoh, Kimio, Shimokawa, Hiroaki · 2017 · European Heart Journal
Cited by 166

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

AIMS: Although balloon pulmonary angioplasty (BPA) improves haemodynamics and short-term prognosis in patients with inoperable chronic thrombo-embolic pulmonary hypertension (CTEPH), the long-term effects of BPA, and procedure-related complications remain to be fully elucidated. METHODS AND RESULTS: From July 2009 to October 2016, we performed a total of 424 BPA sessions in 84 consecutive patients with inoperable CTEPH. We used 3D reconstructed computed tomography to determine target lesions of pulmonary arteries and optical computed tomography to select balloon size, if needed. In 77 patients (92%) who completed the BPA treatment [65 ± 14 (SD) years-old, male/female 14/63], haemodynamics and exercise capacity were examined at 6 months after last BPA and in the chronic phase [>12 months after first BPA, 31 (20, 41) months]. The BPA treatment significantly improved mean pulmonary arterial pressure (38 ± 10 to 25 ± 6 mmHg), pulmonary vascular resistance (7.3 ± 3.2 to 3.8 ± 1.0 Wood units), and 6-minute walk distance (380 ± 138 to 486 ± 112 m) (all P < 0.01), and the improvements persisted throughout the follow-up period (43 ± 27 months) (N = 53). In the 424 sessions, haemoptysis was noted in 60 sessions (14%), and non-invasive positive pressure ventilation (NPPV) was used to treat haemoptysis and/or hypoxemia in 33 sessions (8%). Furthermore, 5-year survival was 98.4% (only one patient died of colon cancer) with no peri-procedural death. CONCLUSION: These results indicate that BPA improves haemodynamics and exercise capacity in inoperable CTEPH patients with acceptable complication rate and that the beneficial haemodynamic effects of BPA persist for years with resultant good long-term prognosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehx530

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

Metadata

Authors
Aoki, T., Sugimura, K., Tatebe, S., Miura, M., Yamamoto, S., Yaoita, N., Suzuki, H., Sato, H., Kozu, K., Konno, R., Miyata, S., Nochioka, K., Satoh, K., & Shimokawa, H.
Venue
European Heart Journal
Published
2017-09-23
Volume
38
Issue
42
Pages
3152-3159
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2760298708
Cited by
166
References
23
FWCI
11.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.