Continued vs. interrupted direct oral anticoagulants at the time of device surgery, in patients with moderate to high risk of arterial thrombo-embolic events (BRUISE CONTROL-2)

Birnie, David H, Healey, Jeff S, Wells, George A, Ayala-Paredes, Felix, Coutu, Benoit, Sumner, Glen L, Becker, Giuliano, Verma, Atul, Philippon, François, Kalfon, Eli, Eikelboom, John, Sandhu, Roopinder K, Nery, Pablo B, Lellouche, Nicholas, Connolly, Stuart J, Sapp, John, Essebag, Vidal · 2018 · European Heart Journal

Abstract

Aims: Guidelines recommend warfarin continuation rather than heparin bridging for pacemaker and defibrillator surgery, after the BRUISE CONTROL trial demonstrated an 80% reduction in device pocket haematoma with this approach. However, direct oral anticoagulants (DOACs) are now used to treat the majority of patients with atrial fibrillation. We sought to understand the best strategy to manage the DOACs at the time of device surgery and specifically hypothesized that performing device surgery without DOAC interruption would result in a reduced haematoma rate. Methods and results: We randomly assigned patients with atrial fibrillation and CHA2DS2-VASc score ≥2, to continued vs. interrupted DOAC (dabigatran, rivaroxaban, or apixaban). The primary outcome was blindly evaluated, clinically significant device pocket haematoma: resulting in re-operation, interruption of anticoagulation, or prolonging hospital stay. In the continued arm, the median time between pre- and post-operative DOAC doses was 12 h; in the interrupted arm the median time was 72 h. Clinically significant haematoma occurred in of 7 of 328 (2.1%; 95% CI 0.9-4.3) patients in the continued DOAC arm and 7 of 334 (2.1%; 95% CI 0.9-4.3) patients in the interrupted DOAC arm (P = 0.97). Complications were uncommon, and included one stroke and one symptomatic pericardial effusion in each arm. Conclusions: These results suggest that, dependent on the clinical scenario, either management strategy (continued DOAC or interrupted DOAC) might be reasonable, at least for patients similar to those enrolled in our trial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehy413

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 192

Metadata

Authors
Birnie, D. H., Healey, J. S., Wells, G. A., Ayala-Paredes, F., Coutu, B., Sumner, G. L., Becker, G., Verma, A., Philippon, F., Kalfon, E., Eikelboom, J., Sandhu, R. K., Nery, P. B., Lellouche, N., Connolly, S. J., Sapp, J., & Essebag, V.
Venue
European Heart Journal
Published
2018-07-25
Volume
39
Issue
44
Pages
3973-3979
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2883546078
Cited by
192
References
3
FWCI
14.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continued vs. interrupted direct oral anticoagulants at the time of device surgery, in patients with moderate to high risk of arterial thrombo-embolic events (BRUISE CONTROL-2). https://app.cochat.ai/papers/10.1093/eurheartj/ehy413
The paper
Birnie, D. H., Healey, J. S., Wells, G. A., Ayala-Paredes, F., Coutu, B., Sumner, G. L., Becker, G., Verma, A., Philippon, F., Kalfon, E., Eikelboom, J., Sandhu, R. K., Nery, P. B., Lellouche, N., Connolly, S. J., Sapp, J., & Essebag, V. (2018). Continued vs. interrupted direct oral anticoagulants at the time of device surgery, in patients with moderate to high risk of arterial thrombo-embolic events (BRUISE CONTROL-2). European Heart Journal. https://doi.org/10.1093/eurheartj/ehy413

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.