Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982–2018)

Open access
Olsen, Thomas, Jørgensen, Ole Dan, Nielsen, Jens Cosedis, Thøgersen, Anna Margrethe, Philbert, Berit Thornvig, Johansen, Jens Brock · 2019 · European Heart Journal

Abstract

Aims: Device-related infection (DRI) is a severe complication to cardiac implantable electronic devices (CIED) therapy. Device-related infection incidence and its risk factors differ between previous studies. We aimed to define the long-term incidence and incidence rates of DRI for different types of CIEDs in the complete Danish device-cohort and identify patient-, operation- and device-related risk factors for DRI. Methods and results: From the Danish Pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Register, we included consecutive Danish patients undergoing CIED implantation or reoperation from January 1982 to April 2018, resulting in 97 750 patients, 128 045 operations and follow-up of in total 566 275 device years (DY). We identified 1827 DRI causing device removals. Device-related infection incidence during device lifetime was 1.19% (1.12–1.26) for PM, 1.91% (1.71–2.13) for ICD, 2.18% (1.78–2.64) for cardiac resynchronization therapy (CRT)-pacemakers (CRT-P), and 3.35% (2.92–3.83) for CRT-defibrillators (CRT-D). Incidence rates in de novo implantations were 2.04/1000 DY for PM, 3.84 for ICD, 4.38 for CRT-P, and 6.76 for CRT-D. Using multiple-record and multiple-event per subject proportional hazard analysis, we identified implantation of complex devices (ICD and CRT), reoperations, prior DRI, male sex, and younger age as significantly associated with higher DRI risk. Conclusion: Overall risk of infection was low in PM implantations but considerably higher in CRT systems and after reinterventions. These data support the importance of evaluating all patients considered for CIED therapy thoroughly, in order to identify potential modifiable risk factors and reduce the risk of early reoperations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehz316

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 238

Metadata

Authors
Olsen, T., Jørgensen, O. D., Nielsen, J. C., Thøgersen, A. M., Philbert, B. T., & Johansen, J. B.
Venue
European Heart Journal
Published
2019-06-01
Volume
40
Issue
23
Pages
1862-1869
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2948562161
Cited by
238
References
3
FWCI
18.55
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982–2018). https://app.cochat.ai/papers/10.1093/eurheartj/ehz316
The paper
Olsen, T., Jørgensen, O. D., Nielsen, J. C., Thøgersen, A. M., Philbert, B. T., & Johansen, J. B. (2019). Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982–2018). European Heart Journal. https://doi.org/10.1093/eurheartj/ehz316

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.