Limited reproducibility of MUCH and WUCH: evidence from the ELSA study
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Aims: To evaluate the long-term reproducibility of masked (MUCH) and white-coat uncontrolled hypertension (WUCH), an information crucial for determining the long-term prognostic impact of these conditions. Methods and results: Reproducibility of MUCH and WUCH was assessed in 1664 hypertensive patients recruited for the European Lacidipine Study on Atherosclerosis and treated with atenolol or lacidipine (±additional drugs) during a 4-year period. Office and 24 h blood pressure (BP) was measured at baseline and every year during treatment, allowing repeated classification of either condition. After 1 year of treatment 21.1% and 17.8% of the patients were classified as MUCH and WUCH, respectively. For both conditions the prevalence was similar in the following years, although with a large change in patients composition because only about 1/3 of patients classified as MUCH or WUCH at one set of office and ambulatory BP measurements maintained the same classification at a subsequent set of measurements. In only 4.5% and 6.2% MUCH and WUCH persisted throughout the treatment period. MUCH and WUCH reproducibility was worse than that of patients showing control or lack of control of both office and ambulatory BP, i.e. controlled and uncontrolled hypertension, respectively. Conclusion: Both MUCH and WUCH display poor reproducibility over time. This should be taken into account in studies assessing the long-term prognostic value of these conditions based on only one set of BP measurements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the ELSA study64, only one-third of 1,664 patients treated for hypertension classified as white-coat or masked hypertension maintained the same classification in repeated annual assessments in the 4-year follow-up.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [64]
Citations
Cites
1 retracted
RETRACTED: Relationship between Clinic and Ambulatory Blood-Pressure Measurements and Mortality
Banegas, J. R., Ruilope, L. M., de la Sierra, A., Vinyoles, E., Gorostidi, M., de la Cruz, J. J., Ruiz-Hurtado, G., Segura, J., Rodríguez-Artalejo, F., & Williams, B. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1712231 · Cited by 490
Retracted(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Self-citation2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Self-citationWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.005 · Cited by 920
EFFECTS OF BLOOD-PRESSURE MEASUREMENT BY THE DOCTOR ON PATIENT'S BLOOD PRESSURE AND HEART RATE
MANCIA, G. (1983) · The Lancet · doi:10.1016/s0140-6736(83)92244-4 · Cited by 744
Self-citationZanchetti, A., Bond, M. G., Hennig, M., Neiss, A., Mancia, G., Dal Palù, C., Hansson, L., Magnani, B., Rahn, K.-H., Reid, J. L., et al. (2002) · Circulation · doi:10.1161/01.cir.0000039288.86470.dd · Cited by 514
Self-citationAlerting reaction and rise in blood pressure during measurement by physician and nurse.
Mancia, G., Parati, G., Pomidossi, G., Grassi, G., Casadei, R., & Zanchetti, A. (1987) · Hypertension · doi:10.1161/01.hyp.9.2.209 · Cited by 483
Self-citationBetter compliance to antihypertensive medications reduces cardiovascular risk
Corrao, G., Parodi, A., Nicotra, F., Zambon, A., Merlino, L., Cesana, G., & Mancia, G. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e328342ca97 · Cited by 367
Self-citation
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Self-citationBlood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Chinese Guidelines for the Prevention and Treatment of Hypertension (2024 revision)
Wang, J. (2025) · 老年心脏病学杂志:英文版 · doi:10.26599/1671-5411.2025.01.008 · Cited by 196
Diagnosis and treatment of arterial hypertension 2021
Ott, C., & Schmieder, R. E. (2021) · Kidney International · doi:10.1016/j.kint.2021.09.026 · Cited by 151
Parati, G., Lombardi, C., Pengo, M. F., Bilo, G., & Ochoa, J. E. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.01.070 · Cited by 133
Metadata
- Authors
- Mancia, G., Facchetti, R., Cuspidi, C., Bombelli, M., Corrao, G., & Grassi, G.
- Affiliations
- University of Milano-Bicocca (IT)
- Corresponding author
- Mancia, Giuseppe
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-09-20
- Volume
- 41
- Issue
- 16
- Pages
- 1565-1571
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2973666334
- Cited by
- 53
- References
- 23
- Citations by year
- 2025: 7 · 2024: 5 · 2023: 7 · 2022: 9 · 2021: 9 · 2020: 14 · 2019: 2
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- European Heart Journal (publishedVersion)
- PubMed (publishedVersion)
- BOA (University of Milano-Bicocca) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Nursing › Nutrition and Dietetics › Sodium Intake and Health
- Keywords
- masked hypertension, reproducibility, hypertension, ambulatory blood pressure monitoring, office blood pressure, lacidipine, atenolol, antihypertensive therapy
- MeSH terms
- Antihypertensive Agents, Blood Pressure, Humans, Hypertension, Reproducibility of Results, Blood Pressure Monitoring, Ambulatory, White Coat Hypertension
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limited reproducibility of MUCH and WUCH: evidence from the ELSA study. https://app.cochat.ai/papers/10.1093/eurheartj/ehz651
- The paper
- Mancia, G., Facchetti, R., Cuspidi, C., Bombelli, M., Corrao, G., & Grassi, G. (2020). Limited reproducibility of MUCH and WUCH: evidence from the ELSA study. European Heart Journal. https://doi.org/10.1093/eurheartj/ehz651
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.