Implementation of Device Therapy (Cardiac Resynchronization Therapy and Implantable Cardioverter Defibrillator) for Patients with Heart Failure in Europe: Changes from 2004 to 2008
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Aims: Heart failure (HF) patients increasingly receive device therapy, either an implantable cardioverter defibrillator (ICD) or a biventricular pacemaker, also called cardiac resynchronization therapy (CRT), or a CRT device with an ICD (CRT-D). However, epidemiological data on the use of device therapy in Europe are limited. Methods and results: Data on implantation rates for conventional pacemakers, ICD, CRT, and CRT-D in 15 Western European countries were obtained from the Eucomed Registry for the 5-year period 2004–2008. Implantation of conventional pacemakers increased by 9% in Europe over the 5 years (reaching 907/million in 2008) and there were significant differences between countries. Implantable cardioverter defibrillator implantations increased by 75% from 80/million in 2004 to 140/million in 2008, and differences between countries were larger than those for conventional pacemakers. Implantation rates for CRT-P alone increased slightly from 2004 to 2006, but remained at 25/million thereafter in Europe overall. The total number of CRT implants (CRT-P and -D) markedly increased from 46/million in 2004 to 99/million in 2008 (115%), but this was mainly due to more CRT-D implants, i.e. an increase in the proportion of CRT-D (from 55% in 2004 to 75% in 2008). Implantation rates for ICD, CRT, and CRT-D remained markedly different throughout the study period between countries. Conclusion: Implantation rates of devices for HF, in particular ICD and CRT-D, have increased significantly between 2004 and 2008 in Europe, but there remain major differences between countries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citationEplerenone in patients with systolic heart failure and mild symptoms
Zannad, F., McMurray, J. J. V., Krum, H., van Veldhuisen, D. J., Swedberg, K., Shi, H., Vincent, J., Pocock, S. J., & Pitt, B. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009492 · Cited by 3,111
Self-citation(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Maggioni, A. P., Anker, S. D., Dahlström, U., Filippatos, G., Ponikowski, P., Zannad, F., Amir, O., Chioncel, O., Leiro, M. C., Drozdz, J., et al. (2013) · European Journal of Heart Failure · doi:10.1093/eurjhf/hft134 · Cited by 667
2010 Focused Update of ESC Guidelines on device therapy in heart failure
Authors/Task Force Members, Dickstein, K., Vardas, P. E., Auricchio, A., Daubert, J.-C., Linde, C., McMurray, J., Ponikowski, P., Priori, S. G., Sutton, R., et al. (2010) · EP Europace · doi:10.1093/europace/euq392 · Cited by 593
Self-citation
Metadata
- Authors
- van Veldhuisen, D. J., Maass, A. H., Priori, S. G., Stolt, P., van Gelder, I. C., Dickstein, K., & Swedberg, K.
- Venue
- European Journal of Heart Failure
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-11-19
- Volume
- 11
- Issue
- 12
- Pages
- 1143-1151
- ISSN
- 1388-9842 (ISSN-L)
- 1879-0844
- OpenAlex
- W2144804227
- Cited by
- 133
- References
- 3
- FWCI
- 12.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of Device Therapy (Cardiac Resynchronization Therapy and Implantable Cardioverter Defibrillator) for Patients with Heart Failure in Europe: Changes from 2004 to 2008. https://app.cochat.ai/papers/10.1093/eurjhf/hfp149
- The paper
- van Veldhuisen, D. J., Maass, A. H., Priori, S. G., Stolt, P., van Gelder, I. C., Dickstein, K., & Swedberg, K. (2009). Implementation of Device Therapy (Cardiac Resynchronization Therapy and Implantable Cardioverter Defibrillator) for Patients with Heart Failure in Europe: Changes from 2004 to 2008. European Journal of Heart Failure. https://doi.org/10.1093/eurjhf/hfp149
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.