Remote monitoring of cardiac implanted electronic devices: legal requirements and ethical principles - ESC Regulatory Affairs Committee/EHRA joint task force report
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The European Union (EU) General Data Protection Regulation (GDPR) imposes legal responsibilities concerning the collection and processing of personal information from individuals who live in the EU. It has particular implications for the remote monitoring of cardiac implantable electronic devices (CIEDs). This report from a joint Task Force of the European Heart Rhythm Association and the Regulatory Affairs Committee of the European Society of Cardiology (ESC) recommends a common legal interpretation of the GDPR. Manufacturers and hospitals should be designated as joint controllers of the data collected by remote monitoring (depending upon the system architecture) and they should have a mutual contract in place that defines their respective roles; a generic template is proposed. Alternatively, they may be two independent controllers. Self-employed cardiologists also are data controllers. Third-party providers of monitoring platforms may act as data processors. Manufacturers should always collect and process the minimum amount of identifiable data necessary, and wherever feasible have access only to pseudonymized data. Cybersecurity vulnerabilities have been reported concerning the security of transmission of data between a patient’s device and the transceiver, so manufacturers should use secure communication protocols. Patients need to be informed how their remotely monitored data will be handled and used, and their informed consent should be sought before their device is implanted. Review of consent forms in current use revealed great variability in length and content, and sometimes very technical language; therefore, a standard information sheet and generic consent form are proposed. Cardiologists who care for patients with CIEDs that are remotely monitored should be aware of these issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic consent: a patient interface for twenty-first century research networks
Kaye, J., Whitley, E. A., Lund, D., Morrison, M., Teare, H., & Melham, K. (2015) · European Journal of Human Genetics · doi:10.1038/ejhg.2014.71 · Cited by 780 · cited 1×
“Manufacturers should investigate with hospitals how this could be provided, perhaps using a common portal that could also be used for dynamic consent.(59) The draft European Strategy for Data states that there is a lack of tools for empowering individuals in enforcing their rights under the GDPR, such as ‘web-based in…”
BackgroundVarma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citationTorous, J., Bucci, S., Bell, I. H., Kessing, L. V., Faurholt‐Jepsen, M., Whelan, P., Carvalho, A. F., Keshavan, M., Linardon, J., & Firth, J. (2021) · World Psychiatry · doi:10.1002/wps.20883 · Cited by 1,199
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citationHow to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Self-citationJensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93
Self-citation
Metadata
- Authors
- Nielsen, J. C., Kautzner, J., Casado-Arroyo, R., Burri, H., Callens, S., Cowie, M. R., Dickstein, K., Drossart, I., Geneste, G., Erkin, Z., Hyafil, F., Kraus, A., Kutyifa, V., Marin, E., Schulze, C., Slotwiner, D., Stein, K., Zanero, S., Heidbuchel, H., & Fraser, A. G.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-07-29
- Volume
- 22
- Issue
- 11
- Pages
- 1742-1758
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W3045565881
- Cited by
- 38
- References
- 2
- FWCI
- 46.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Remote monitoring of cardiac implanted electronic devices: legal requirements and ethical principles - ESC Regulatory Affairs Committee/EHRA joint task force report. https://app.cochat.ai/papers/10.1093/europace/euaa168
- The paper
- Nielsen, J. C., Kautzner, J., Casado-Arroyo, R., Burri, H., Callens, S., Cowie, M. R., Dickstein, K., Drossart, I., Geneste, G., Erkin, Z., Hyafil, F., Kraus, A., Kutyifa, V., Marin, E., Schulze, C., Slotwiner, D., Stein, K., Zanero, S., Heidbuchel, H., & Fraser, A. G. (2020). Remote monitoring of cardiac implanted electronic devices: legal requirements and ethical principles - ESC Regulatory Affairs Committee/EHRA joint task force report. EP Europace. https://doi.org/10.1093/europace/euaa168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.