Abstract

In the originally published version of this manuscript, the names of authors Marcio Jansen de Oliveira Figueiredo and Manlio F. Márquez were incorrectly given. Both names have now been corrected online. In addition, the following affiliation was inadvertently omitted for author Manlio F. Márquez: Cardiology, Electrophysiology Service, American British Cowdray Medical Center, Mexico City, México This affiliation has now been added to the online version of the manuscript as affiliation 27 and all subsequent affiliations in this manuscript affected by this change have been updated accordingly.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euac038

Cites

169 of 169 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Overview of digital heart rhythm devices for the clinic. Suggest reading the figure from the inner circle-devices have been divided into devices that provide photoplethysmography (PPG) or electrocardiogram (ECG), followed by the mode of handheld or wearable, and then placement on the body, number of leads, and device type. */**Please see Table 2 for further details. ECG, electrocardiogram; L, lead; mApp, mobile App; PPG, photoplethysmography.
Figure 1 Overview of digital heart rhythm devices for the clinic. Suggest reading the figure from the inner circle-devices have been divided into devices that provide photoplethysmography (PPG) or electrocardiogram (ECG), followed by the mode of handheld or wearable, and then placement on the body, number of leads, and device type. */**Please see Table 2 for further details. ECG, electrocardiogram; L, lead; mApp, mobile App; PPG, photoplethysmography.CC-BY-NC-ND · From the PDF
Figure 2 Comparison of photoplethysmography (PPG) vs. electrogram (ECG)-based techniques. In the lower part of the figure an example of a registration from a patient with atrial fibrillation is shown.
Figure 2 Comparison of photoplethysmography (PPG) vs. electrogram (ECG)-based techniques. In the lower part of the figure an example of a registration from a patient with atrial fibrillation is shown.CC-BY-NC-ND · From the PDF
Figure 3 Choice of ECG device in symptomatic patient. If possible, subject to availability and duration of symptoms a 12-lead ECG should be achieved to evaluate symptomatic arrhythmias. In case of difficulties achieving a 12-lead ECG during symptomatic episodes, assess the frequency of symptoms and patient preference prior to choosing long-term ECG device for heart rhythm monitoring. ( ✓ ) possible use; 12 L, 12 lead; ECG, electrocardiogram; ILR, implantable loop recorder.
Figure 3 Choice of ECG device in symptomatic patient. If possible, subject to availability and duration of symptoms a 12-lead ECG should be achieved to evaluate symptomatic arrhythmias. In case of difficulties achieving a 12-lead ECG during symptomatic episodes, assess the frequency of symptoms and patient preference prior to choosing long-term ECG device for heart rhythm monitoring. ( ✓ ) possible use; 12 L, 12 lead; ECG, electrocardiogram; ILR, implantable loop recorder.CC-BY-NC-ND · From the PDF
Image 4
CC-BY-NC-ND · From the PDF
Image 5
CC-BY-NC-ND · From the PDF
Figure 5 Considerations for atrial fibrillation screening programme (systematic or opportunistic) and digital device based on patient age, comorbidities, and digital literacy.
Figure 5 Considerations for atrial fibrillation screening programme (systematic or opportunistic) and digital device based on patient age, comorbidities, and digital literacy.CC-BY-NC-ND · From the PDF
Image 7
CC-BY-NC-ND · From the PDF
Image 8
CC-BY-NC-ND · From the PDF
Figure 8 The potential uses of digital devices in patients with atrial fibrillation.
Figure 8 The potential uses of digital devices in patients with atrial fibrillation.CC-BY-NC-ND · From the PDF
Figure 9 Practical examples of digital AF management. Note that for Panels 2-4 randomized controlled trials are still lacking, and these should be views as examples of ongoing practical applications of digital tools. For all on demand remote heart rate/rhythm monitoring, an experienced physician should verify the findings by the device.
Figure 9 Practical examples of digital AF management. Note that for Panels 2-4 randomized controlled trials are still lacking, and these should be views as examples of ongoing practical applications of digital tools. For all on demand remote heart rate/rhythm monitoring, an experienced physician should verify the findings by the device.CC-BY-NC-ND · From the PDF
Image 11
CC-BY-NC-ND · From the PDF
Image 12
CC-BY-NC-ND · From the PDF
Figure 12 Athlete with sudden heart rate accelerations documented on heart rate monitoring device. An athlete (48-year old male) presented to the outpatient clinic with palpitations during cycling exercise with heart rate accelerations from 120 to 180 b.p.m. without any clear triggers. His chest strap band (Garmin Edge 1030) output showed a sudden start and onset of the episodes, which coincided with subjective palpitations. The combination of known chest strap accuracy and symptoms made an arrhythmia likely. Since cardiac evaluation ruled out structural heart disease, and the episodes were of longer duration (see Flowchart A), patient-activated ECG recording was deemed necessary. The patient also happened to have an Apple Watch 4 and was instructed to record an ECG on recurrence of symptoms and/or heart rate accelerations (see Flowchart B, left-sided scenario). He subsequently presented with a recording taken after an heart rate jump and complaints of palpitations (blue dotted circle), which confirmed an SVT (which terminated at the end of recording).
Figure 12 Athlete with sudden heart rate accelerations documented on heart rate monitoring device. An athlete (48-year old male) presented to the outpatient clinic with palpitations during cycling exercise with heart rate accelerations from 120 to 180 b.p.m. without any clear triggers. His chest strap band (Garmin Edge 1030) output showed a sudden start and onset of the episodes, which coincided with subjective palpitations. The combination of known chest strap accuracy and symptoms made an arrhythmia likely. Since cardiac evaluation ruled out structural heart disease, and the episodes were of longer duration (see Flowchart A), patient-activated ECG recording was deemed necessary. The patient also happened to have an Apple Watch 4 and was instructed to record an ECG on recurrence of symptoms and/or heart rate accelerations (see Flowchart B, left-sided scenario). He subsequently presented with a recording taken after an heart rate jump and complaints of palpitations (blue dotted circle), which confirmed an SVT (which terminated at the end of recording).CC-BY-NC-ND · From the PDF
Image 14
CC-BY-NC-ND · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 169 references

Research works printed but not linked: 2

  1. Gawałko, 2021, The European TeleCheck-AF project on remote app-based management of atrial fibrillation during the COVID-19 pandemic: centre and patient experiences, Europace, 23, 1003, 10.1093/europace/euab050 · DOI · Paper page
  2. López, 2020, Usefulness of a single-lead electrocardiographic recording system and wireless transmission during the COVID-19 pandemic, Argent J Cardiol, 88, 211

Cited by

Items 101–200 of 261

Metadata

Authors
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., Deneke, T., Drossart, I., Duncker, D., Han, J. K., Heidbuchel, H., Jais, P., de Oliveira Figueiredo, M. J., Linz, D., Lip, G. Y. H., Malaczynska-Rajpold, K., Márquez, M. F., Ploem, C., Soejima, K., Stiles, M. K., Wierda, E., Vernooy, K., Leclercq, C., Meyer, C., Pisani, C., Pak, H. N., Gupta, D., Pürerfellner, H., Crijns, H. J. G. M., Chavez, E. A., Willems, S., Waldmann, V., Dekker, L., Wan, E., Kavoor, P., Turagam, M. K., & Sinner, M.
Affiliations
  • Karolinska Institutet (SE)
  • Amsterdam University Medical Centers (NL)
  • Atrial Fibrillation NETwork (DE)
  • University of Washington (US)
  • Albert Einstein College of Medicine at Montefiore Hospital, New York , NY ,
  • Electrophysiology and Heart Modeling Institute (FR)
  • University of Modena and Reggio Emilia (IT)
  • University Hospital of Geneva (CH)
  • Ente Ospedaliero Cantonale (CH)
  • Aix-Marseille Université (FR)
  • Rhön-Klinikum (DE)
  • European Society of Cardiology (FR)
  • Medizinische Hochschule Hannover (DE)
  • University of California, Los Angeles (US)
  • Department of Cardiology, Antwerp University Hospital , Antwerp ,
  • Bordeaux University Hospital , Bordeaux ,
  • University of Campinas (UNICAMP) , Campinas ,
  • Maastricht University Medical Centre (NL)
  • University of Liverpool (GB)
  • Heart Division, Royal Brompton and Harefield Hospitals, Guy’s and St. Thomas’ NHS Foundation Trust , London ,
  • Instituto Nacional de Cardiología (MX)
  • Department of Ethics, Law and Medical Humanities, Amsterdam University Medical Centers, University of Amsterdam , Amsterdam ,
  • Kyorin University (JP)
  • University of Auckland (NZ)
  • Dijklander Ziekenhuis (NL)
  • Laboratoire Traitement du Signal et de l'Image (FR)
  • Düsseldorf University Hospital (DE)
  • Universidade de São Paulo (BR)
  • Yonsei University (KR)
  • Krankenhaus der Elisabethinen (AT)
  • Maastricht University (NL)
  • Division of Cardiology, Hospital General de Agudos Dr. Cosme Argerich , Pi y Margall 750, C1155AHB Buenos Aires ,
  • Asklepios Klinik St. Georg (DE)
  • Hôpital Européen Georges-Pompidou (FR)
  • Catharina Ziekenhuis (NL)
  • Columbia University (US)
  • Westmead Hospital (AU)
  • Icahn School of Medicine at Mount Sinai (US)
  • Univ. Hospital Munich, Campus Grosshadern , Munich ,
Venue
Europace
Published
2022-04-03
Volume
24
Issue
6
Pages
979-1005
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W4214908860
Cited by
261
References
169
Citations by year
2026: 27 · 2025: 55 · 2024: 79 · 2023: 61 · 2022: 39
FWCI
40.70
Type
journal article
Language
en
Open access
Locations
  • EP Europace (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • YUHSpace (Yonsei University Medical Library) (submittedVersion, cc-by-nc-nd)
  • Pure Amsterdam UMC (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
  • HAL (submittedVersion)
  • Research Publications (Maastricht University) (submittedVersion, other-oa)
  • IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
  • VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
  • Archive ouverte UNIGE (University of Geneva) (submittedVersion, other-oa)
  • VUBIR (Vrije Universiteit Brussel) (submittedVersion)
Funders
  • Amsterdam University Medical Centers
  • Novo Nordisk Fonden (NNF21OC0066480)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
arrhythmia detection, arrhythmia management, digital devices, wearable devices, cardiac implantable electronic devices, arrhythmia monitoring
MeSH terms
Arrhythmias, Cardiac, Humans, Catheter Ablation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.