Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 195

The DOI matches its Crossref record.

Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade

Open access
Haghjoo, Majid, Nikoo, Mohammad Hossein, Fazelifar, Amir Farjam, Alizadeh, Abolfath, Emkanjoo, Zahra, Sadr-Ameli, Mohammad Ali · 2007 · EP Europace

Abstract

AIM: Venous obstruction following transvenous device implantation rarely cause immediate clinical problems. When lead revision or device upgrade is indicated, venous obstruction become a significant challenge. The aim of this study was to determine the predictors of venous obstruction after transvenous device implantation, and to asess likely effects of antiplatelet/anticoagulant drugs in preventing venous thrombosis. METHODS AND RESULTS: Between March 2005 and July 2006, contrast venography was performed in 100 patients who were candidates for generator change, lead revision, or device upgrade. Vessel patency was graded as either completely obstructed, partially obstructed (>70%), or patent. The incidence of venous obstruction was 26%, with 9% of patients having total obstruction and 17% of patients exhibiting partial obstruction. No statistically significant differences between obstructed and non-obstructed patients were seen for age, sex, indication for device implantation, atrial fibrillation, cardiothoracic ratio, insulation material, operative technique, device type, and manufacturer (all Ps > 0.05). In a univariate analysis, multiple leads (P = 0.033), and presence of dilated cardiomyopathy (P = 0.036) were associated with higher risk of venous obstruction, whereas anticoagulant/antiplatelet therapy (P = 0.047) significantly reduced incidence of venous obstruction. Multivariate logistic regression analysis showed that only number of the leads (P = 0.039, OR: 2.22, and 95% CI: 1.03-4.76) and antiplatelet/anticoagulant therapy (P = 0.044, OR: 2.79, and 95% CI: 0.98-7.96) were predictors of venous obstruction. CONCLUSION: Total or partial obstruction of the access veins occurs relatively frequently after pacemaker or ICD implantation. Multiple pacing or ICD leads are associated with an increased risk of venous obstruction, whereas antiplatelet/anticoagulant therapy appears to have a preventive effect on development of access vein thrombosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eum019

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
Haghjoo, M., Nikoo, M. H., Fazelifar, A. F., Alizadeh, A., Emkanjoo, Z., & Sadr-Ameli, M. A.
Venue
EP Europace
Published
2007-03-16
Volume
9
Issue
5
Pages
328-332
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2123602435
Cited by
195
References
0
FWCI
4.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade. https://app.cochat.ai/papers/10.1093/europace/eum019
The paper
Haghjoo, M., Nikoo, M. H., Fazelifar, A. F., Alizadeh, A., Emkanjoo, Z., & Sadr-Ameli, M. A. (2007). Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade. EP Europace. https://doi.org/10.1093/europace/eum019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.