Abrupt changes in fibrillatory wave characteristics at the termination of paroxysmal atrial fibrillation in humans
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
AIMS: We investigated the process of spontaneous termination of atrial fibrillation (AF) to determine its time course from the surface ECG. METHODS AND RESULTS: We studied fibrillatory waves in Holter recordings of paroxysmal and sustained AF. Following QRS-T cancellation dominant frequencies (DFs) were computed and the relationship of DF to termination was scrutinized. For 57 episodes of paroxysmal AF (PAF) in 24 patients, DF ranged from 4.4 to 6.5 Hz (5.2 +/- 0.4 Hz) compared to 5.8 to 7.4 Hz (6.6 +/- 0.6 Hz) for sustained AF recordings. Comparison of the atrial frequency of the ultimate to the penultimate second demonstrated a drop in frequency in 51 of 57 episodes, P < 0.00001. No comparable change was seen at longer time periods. Moments of comparably low frequency without termination were only occasionally seen in patients with PAF but not in patients with sustained AF. CONCLUSION: Low frequency fibrillation was found to be much more likely to terminate. Frequency changes preceding spontaneous termination were abrupt, in contrast to the gradual frequency drop reported with drug-induced termination. The analysis of fibrillatory wave characteristics and their change over time might be used to target specific moments for pacing therapy in patients with AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Atrial Fibrillation Begets Atrial Fibrillation: A Study in Awake Chronically Instrumented Goats
Wijffels, M. C. E. F., Kirchhof, C. J. H. J., Dorland, R., & Allessie, M. A. (1995) · Circulation · doi:10.1161/01.cir.92.7.1954 · Cited by 3,494
On the multiple wavelet hypothesis o f atrial fibrillation.
Moe, G. K. (1962) · Medical Entomology and Zoology · Cited by 913
Structural Changes of Atrial Myocardium due to Sustained Atrial Fibrillation in the Goat
Ausma, J., Wijffels, M., Thoné, F., Wouters, L., Allessie, M., & Borgers, M. (1997) · Circulation · doi:10.1161/01.cir.96.9.3157 · Cited by 638 · cited 1×
“It is not known why AF is self-terminating in certain individuals but not in others although electrophysiological and structural remodeling during AF are believed to play a part in the transition from paroxysmal (PAF) to permanent AF.(1,2) The duration of episodes of spontaneously terminating AF varies from patient to…”
BackgroundStructural Changes of Atrial Myocardium due to Sustained Atrial Fibrillation in the Goat
JannieAusma, MauritsWijffels, FredThoné, LucWouters, MauritsAllessie, & MarcelBorgers (1997) · Circulation · Cited by 618
Mother rotors and fibrillatory conduction: a mechanism of atrial fibrillation
Jalife, J. (2002) · Cardiovascular Research · doi:10.1016/s0008-6363(02)00223-7 · Cited by 587
Bollmann, A., Kanuru, N. K., McTeague, K., Walter, P. F., DeLurgio, D. B., & Langberg, J. J. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00210-0 · Cited by 276
Holm, M. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00289-7 · Cited by 275
A new pacemaker algorithm for the treatment of atrial fibrillation
Carlson, M. D., Ip, J., Messenger, J., Beau, S., Kalbfleisch, S., Gervais, P., Cameron, D. A., Duran, A., Val-Mejias, J., Mackall, J., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00780-0 · Cited by 235 · cited 1×
“The ATTEST trial determined that atrial prevention and termination therapies combined did not reduce burden, total frequency, or symptomatic frequency of AF.(4) Anti-tachycardia pacing (ATP) only achieves local capture in AF(26,27) and although it has been successful in pace-terminating other atrial tachyarrhythmias,(…”
BackgroundWang, J., Bourne, G. W., Wang, Z., Villemaire, C., Talajic, M., & Nattel, S. (1993) · Circulation · doi:10.1161/01.cir.88.3.1030 · Cited by 209
Cited by
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
Detection of atrial fibrillation using a wrist-worn device
Sološenko, A., Petrėnas, A., Paliakaitė, B., Sörnmo, L., & Marozas, V. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab029c · Cited by 45
Metadata
- Authors
- Petrutiu, S., Sahakian, A. V., & Swiryn, S.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-05-31
- Volume
- 9
- Issue
- 7
- Pages
- 466-470
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2109127420
- Cited by
- 221
- References
- 21
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.