Atrial fibrillatory cycle length: computer simulation and potential clinical importance
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: Atrial fibrillatory cycle length (AFCL) is generally accepted as a surrogate marker for local refractoriness. In this study, a computer model and clinical data on human subjects undergoing catheter ablation for paroxysmal and persistent AF were used to determine the clinical potential of AFCL. METHODS AND RESULTS: Simulations were performed in a biophysical computer model of AF, induced from eight simultaneously active focal sources. Atrial fibrillatory cycle length persistence and termination were assessed in response to successively switching off the involvement of the eight sources. Electrophysiological data were obtained from 178 subjects undergoing catheter ablation of AF. Atrial fibrillatory cycle length, measured in the atria appendages using automated monitoring software, was studied to determine its clinical correlation, the complexity of the ablation procedure, and the AF termination success rate. Computer simulations showed an inverse relationship between the number of sources participating in AF maintenance and AFCL. Clinical data demonstrated a strong relationship between duration, degree of ablation, and AFCL, with shorter AFCL associated with more extensive ablation to terminate AF. Atrial fibrillatory cycle length was prolonged exponentially at each stage, with a critical cycle length of approximately 200 ms for AF conversion. CONCLUSION: Atrial fibrillatory cycle length is inversely associated with the number of sources participating in AF maintenance observed in the computer model. In addition, AFCL is an important predictor of baseline duration of the arrhythmia, type of AF, and ease of catheter ablation therapy to terminate AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Franz, M. R., Karasik, P. L., Li, C., Moubarak, J., & Chavez, M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00385-9 · Cited by 301
Cited by
O'Neill, M. D., Wright, M., Knecht, S., Jais, P., Hocini, M., Takahashi, Y., Jonsson, A., Sacher, F., Matsuo, S., Lim, K. T., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp063 · Cited by 333
Self-citationLeft atrial linear lesions are required for successful treatment of persistent atrial fibrillation
Knecht, S., Hocini, M., Wright, M., Lellouche, N., O'Neill, M. D., Matsuo, S., Nault, I., Chauhan, V. S., Makati, K. J., Bevilacqua, M., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn302 · Cited by 259
Self-citationJadidi, A. S., Cochet, H., Shah, A. J., Kim, S. J., Duncan, E., Miyazaki, S., Sermesant, M., Lehrmann, H., Lederlin, M., Linton, N., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.03.081 · Cited by 225
Self-citationNarayan, S. M., Shivkumar, K., Krummen, D. E., Miller, J. M., & Rappel, W.-J. (2013) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.111.977264 · Cited by 171
“If asynchronous, sources may create AF through interference and wave collision.(32) However, we(15) and others(36) have also mapped human AF from a single source where FIRM terminated AF, rendered it nonreinducible and eliminated AF on follow-up (for instance, cases in Figures 2 and 3).”
Corrado, C., Williams, S., Karim, R., Plank, G., O’Neill, M., & Niederer, S. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.04.005 · Cited by 50
Metadata
- Authors
- Haissaguerre, M., Lim, K.-T., Jacquemet, V., Rotter, M., Dang, L., Hocini, M., Matsuo, S., Knecht, S., Jais, P., & Virag, N.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-11-01
- Volume
- 9
- Issue
- Supplement 6
- Pages
- vi64-vi70
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2126828980
- Cited by
- 93
- References
- 1
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.