Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Remote control of implanted devices through Home MonitoringTM technology improves detection and clinical management of atrial fibrillation

Open access
Ricci, R. P., Morichelli, L., Santini, M. · 2008 · Europace

Abstract

AIMS: To evaluate the impact of Home Monitoring (HM) technology on detection and treatment of atrial fibrillation (AF). METHODS AND RESULTS: One hundred and sixty-six patients (mean age 73 +/- 10 years, 112 males) received HM devices [121 pacemakers, 22 implantable cardioverter defibrillators (ICDs), and 23 ICDs combined with cardiac resynchronization therapy]. A nurse consulted the cardioreports on the website and submitted the alerts for AF (new onset AF, persistent AF, and AF burden of >10% for >5 consecutive days) to the physician. During a mean follow-up of 488 +/- 203 days, 42 patients (26%) had alerts for AF. Twenty-two patients had no history of AF before implant. In nine patients, no further action was taken. For the remaining 33 patients, an unscheduled follow-up was performed: in 16, antiarrhythmic drug therapy was introduced/modified; in 15, anticoagulation was started; in 2, antiplatelet drugs were introduced; in 7, an external cardioversion was performed; in 2 patients, the device was reprogrammed to avoid intermittent atrial undersensing during AF; and in 4 patients, no further action was taken. In four cases the arrhythmia was not confirmed (false positive). The median time to the first intervention for AF was 50 days (148 days before the scheduled follow-up). CONCLUSION: The HM technology allowed early detection of AF in paced patients and early reaction to optimize medical treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eun303

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 169

Metadata

Authors
Ricci, R. P., Morichelli, L., & Santini, M.
Venue
Europace
Published
2008-11-12
Volume
11
Issue
1
Pages
54-61
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W1969065299
Cited by
169
References
3
FWCI
9.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Remote control of implanted devices through Home MonitoringTM technology improves detection and clinical management of atrial fibrillation. https://app.cochat.ai/papers/10.1093/europace/eun303
The paper
Ricci, R. P., Morichelli, L., & Santini, M. (2008). Remote control of implanted devices through Home MonitoringTM technology improves detection and clinical management of atrial fibrillation. Europace. https://doi.org/10.1093/europace/eun303

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.