Remote Monitoring of Implantable Cardioverter Defibrillators: A Prospective Analysis
Abstract
A prospective study evaluating the functionality and ease of use of the Medtronic CareLink ® Network, “CareLink,” was conducted at ten investigational sites. This internet‐based remote monitoring service allows clinicians to remotely manage their patients' implantable cardioverter defibrillators (ICDs) and chronic diseases. The network is comprised of a patient monitor, a secure server, and clinician and patient websites. Under clinician direction, patients interrogated their ICDs at home, and transmitted data to secure servers via a standard telephone line. Comprehensive device data and a 10‐second presenting rhythm electrogram were captured by the monitor and available for access and review on the clinician website. The information could also be printed using a standard desktop computer with internet access. During this study, patients were asked to transmit device data twice, at least 7 days apart, as scheduled by the clinic. Monitor functionality was assessed, and ease of using the system components was evaluated via questionnaires completed by patients and clinicians following each data transmission and review. Fifty‐nine patients (64 ± 14 years, range 22‐85 years) completed 119 transmissions with only 14 calls to the study support center. Clinician review of data transmissions revealed several clinically significant findings, including silent AF discovery, assessment of antiarrhythmic drug efficacy in a previously diagnosed AF patient, previously unobserved atrial undersensing, and ventricular tachycardia. ICD patients found the monitor easy to use. Clinicians were pleased with the performance of the network and the quality of the web‐accessed data, and found it comparable to an in‐office device interrogation. CareLink is a practical tool for routine device management and may allow timely identification of clinically important issues. (PACE 2004; 27[Pt. I]:757–763)
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
5 (56%) of the 9 studies demonstrated a benefit of telemonitoring on patient satisfaction when compared with a comparator.
“A total of 56% (5/9) of the studies [22,28,42,78,91] demonstrated a benefit of telemonitoring on patient satisfaction when compared with a comparator”
From Interactive Remote Patient Monitoring Devices for Managing Chronic Health Conditions: Systematic Review and Meta-analysis (2022) · cites this paper as [91]
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885 · see citing works
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165 · see citing works
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221 · see citing works
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489 · see citing works
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,272 · see citing works
Self-citationGregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 905 · see citing works
Self-citationClinical Cardiac Pacing and Defibrillation
(2001) · Journal of Intensive Care Medicine · doi:10.1046/j.1525-1489.2001.00053-2.x · Cited by 184 · see citing works
Winters, S. L., Packer, D. L., Marchlinski, F. E., Lazzara, R., Cannom, D. S., BREITHARDT, G. E., WILBER, D. A., Camm, A. J., & Ruskin, J. N. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00262.x · Cited by 68 · see citing works
Bernstein, A. D., IRWIN, M. E., Parsonnet, V., Wilkoff, B. L., BLACK, W. R., Buckingham, T. A., Maloney, J. D., Reynolds, D., Saksena, S. V., Singer, I., et al. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb03738.x · Cited by 60 · see citing works
Cardiology workforce: there’s already a shortage, and it’s getting worse!
Fye, W. B. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01935-6 · Cited by 46 · see citing works
Device Follow‐up in the Age of Automaticity
Schoenfeld, M. H., & Markowitz, H. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00847.x · Cited by 26 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546 · see citing works
Self-citationACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,768 · see citing works
Self-citationEpstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,495 · see citing works
Self-citationInappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zaręba, W., Cannom, D. S., McNitt, S. A., Rosero, S. Z., Wang, P. J., Schuger, C. D., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 810 · see citing works
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 738 · see citing works
Self-citationVarma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594 · see citing works
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 550 · see citing works
Self-citationSlotwiner, D. J., Varma, N., Akar, J. G., Annas, G. J., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 533 · see citing works
Self-citationThe CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526 · see citing works
Self-citationStellios, I., Kotzanikolaou, P., Psarakis, M., Alcaraz, C., & López, J. (2018) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2855563 · Cited by 457 · see citing works
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364 · see citing works
Self-citationLandolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344 · see citing works
Varma, N., Piccini, J. P., Snell, J. D., Fischer, A., Dalal, N., & Mittal, S. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.033 · Cited by 232 · see citing works
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Europace · doi:10.1093/europace/eun122 · Cited by 231 · see citing works
Self-citationLazarus, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00595.x · Cited by 227 · see citing works
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.001 · Cited by 202 · see citing works
Self-citationRaatikainen, M. J. P., Uusimaa, P., van Ginneken, M. M. E., Janssen, J. P. G., & Linnaluoto, M. (2008) · Europace · doi:10.1093/europace/eun203 · Cited by 189 · see citing works
Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
Burri, H., & Senouf, D. (2009) · EP Europace · doi:10.1093/europace/eup110 · Cited by 180 · see citing works
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P. E., Stone, P. H., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P. F., BREITHARDT, G. E., et al. (2012) · EP Europace · doi:10.1093/europace/eur303 · Cited by 178 · see citing works
Ricci, R. P., Morichelli, L., & Santini, M. (2008) · EP Europace · doi:10.1093/europace/eum289 · Cited by 178 · see citing works
Robust Cyber–Physical Systems: Concept, models, and implementation
Hu, F., Lu, Y., Vasilakos, A. V., Hao, Q., Ma, R., Patil, Y. J., Zhang, T., Lu, J., Li, X., & Xiong, N. N. (2015) · Future Generation Computer Systems · doi:10.1016/j.future.2015.06.006 · Cited by 174 · see citing works
Ricci, R. P., Morichelli, L., & Santini, M. (2008) · EP Europace · doi:10.1093/europace/eun303 · Cited by 169 · see citing works
Automatic Remote Monitoring of Implantable Cardioverter-Defibrillator Lead and Generator Performance
Varma, N., Michalski, J., Epstein, A. E., & Schweikert, R. A. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.951962 · Cited by 164 · see citing works
Swerdlow, C. D., Gunderson, B. D., Ousdigian, K. T., Abeyratne, A., Stadler, R. W., Gillberg, J. M., Patel, A. S., & Ellenbogen, K. A. (2008) · Circulation · doi:10.1161/circulationaha.108.796136 · Cited by 141 · see citing works
Long-term patient acceptance of and satisfaction with implanted device remote monitoring
Ricci, R. P., Morichelli, L., Quarta, L., Sassi, A. D. G., Porfili, A., Laudadio, M. T., Gargaro, A., & Santini, M. (2010) · EP Europace · doi:10.1093/europace/euq046 · Cited by 138 · see citing works
MARZEGALLI, M., LUNATI, M., LANDOLINA, M., PEREGO, G. B., RICCI, R. P., GUENZATI, G., SCHIRRU, M., BELVITO, C., BRAMBILLA, R., MASELLA, C., et al. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01175.x · Cited by 134 · see citing works
Advanced ICD Troubleshooting: Part I
Swerdlow, C. D., & Friedman, P. A. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00275.x · Cited by 133 · see citing works
Hauser, R. G., Maisel, W. H., Friedman, P. A., Kallinen, L. M., Mugglin, A. S., Kumar, K., Hodge, D. O., Morrison, T. B., & Hayes, D. L. (2011) · Circulation · doi:10.1161/circulationaha.110.975219 · Cited by 121 · see citing works
Boriani, G., Costa, A. D., Ricci, R. P., Quesada, A., Favale, S., Iacopino, S., Romeo, F., Risi, A., Stefano, L. M. D. S., Navarro, X., et al. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2608 · Cited by 107 · see citing works
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102 · see citing works
Swerdlow, C. D., Gunderson, B. D., Ousdigian, K. T., Abeyratne, A., Sachanandani, H., & Ellenbogen, K. A. (2010) · Circulation · doi:10.1161/circulationaha.110.962407 · Cited by 99 · see citing works
Jung, W., Rillig, A., Birkemeyer, R., Miljak, T., & Meyerfeldt, U. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9311-5 · Cited by 96 · see citing works
Kallinen, L. M., Hauser, R. G., Lee, K. W., Almquist, A. K., Katsiyiannis, W. T., Tang, C. Y., Melby, D. P., & Gornick, C. C. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.02.039 · Cited by 92 · see citing works
Automatic home monitoring of implantable cardioverter defibrillators
Nielsen, J. C., Kottkamp, H., Zabel, M., Aliot, E., Kreutzer, U., Bauer, A., Schuchert, A., Neuser, H., Schumacher, B., Schmidinger, H., et al. (2008) · EP Europace · doi:10.1093/europace/eun099 · Cited by 84 · see citing works
eHealth in cardiovascular medicine: A clinical update
Saner, H. E., & van der Velde, E. T. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316670256 · Cited by 73 · see citing works
Santini, M., Ricci, R. P., Lunati, M., Landolina, M., Perego, G. B., Marzegalli, M., Schirru, M., Belvito, C., Brambilla, R., Guenzati, G., et al. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9321-3 · Cited by 71 · see citing works
Simone, A. D., Leoni, L., Luzi, M., Amellone, C., Stabile, G., Rocca, V. L., Capucci, A., D’Onofrio, A., Ammendola, E., Accardi, F., et al. (2015) · EP Europace · doi:10.1093/europace/euu318 · Cited by 69 · see citing works
Leo, D. G., Buckley, B. J. R., Chowdhury, M., Harrison, S. L., Isanejad, M., Lip, G. Y. H., Wright, D. J., Lane, D. A., & the TAILOR investigators (2022) · Journal of Medical Internet Research · doi:10.2196/35508 · Cited by 62 · see citing works
Braunschweig, F., Ford, I., Conraads, V. M., Cowie, M., Jondeau, G., Kautzner, J., Lunati, M., Aguilera, R. M., Yu, C., Marijianowski, M. M. H., et al. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.06.016 · Cited by 60 · see citing works
Remote monitoring of cardiac implantable electronic devices and disease management
Varma, N., Braunschweig, F., Burri, H., Hindricks, G., Linz, D., Michowitz, Y., Ricci, R. P., & Nielsen, J. C. (2023) · EP Europace · doi:10.1093/europace/euad233 · Cited by 57 · see citing works
Varma, N. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.07.051 · Cited by 57 · see citing works
Yee, R., Verma, A., Beardsall, M., Fraser, J. A., Philippon, F., & Exner, D. V. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.11.036 · Cited by 54 · see citing works
Timmermans, I., Meine, M., Szendey, I., Aring, J., Roldán, J. R., van Erven, L., Kahlert, P., Zitron, E., Mabo, P., Denollet, J., et al. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13574 · Cited by 53 · see citing works
Boriani, G., Diemberger, I., Martignani, C., Biffi, M., Valzania, C., Bertini, M., Domenichini, G., Saporito, D., Ziacchi, M., & Branzi, A. (2007) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0355-5 · Cited by 53 · see citing works
Advanced ICD Troubleshooting: Part II
Swerdlow, C. D., & Friedman, P. A. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00300.x · Cited by 53 · see citing works
Remote Monitoring for Advisories: Automatic Early Detection of Silent Lead Failure
Varma, N. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02314.x · Cited by 52 · see citing works
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47 · see citing works
Varma, N., Pavri, B. B., Stambler, B. S., Michalski, J., & TRUST Investigators (2012) · EP Europace · doi:10.1093/europace/eus410 · Cited by 47 · see citing works
Remote monitoring of cardiac implantable electronic devices (CIED)
Zeitler, E. P., & Piccini, J. P. (2016) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2016.03.012 · Cited by 46 · see citing works
Contemporary Pacemaker and Defibrillator Device Therapy
Schoenfeld, M. H. (2007) · Circulation · doi:10.1161/circulationaha.106.618587 · Cited by 45 · see citing works
Self-citationRemote implantable cardioverter defibrillator monitoring in a Brugada syndrome population
Sacher, F., Probst, V., Bessouet, M., Wright, M. J., Maluski, A., Abbey, S., Bordachar, P., Deplagne, A., Ploux, S., Lande, G., et al. (2008) · EP Europace · doi:10.1093/europace/eup034 · Cited by 44 · see citing works
Lunati, M., Gasparini, M., Santini, M., Landolina, M., Perego, G. B., Pappone, C., Marzegalli, M., ARGIOLAS, C., Murthy, A., Valsecchi, S., et al. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00923.x · Cited by 41 · see citing works
Compliance with Remote Monitoring of ICDS/CRTDS in a Real‐World Population
Rosenfeld, L. E., Patel, A. S., Ajmani, V. B., Holbrook, R., & BRAND, T. A. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12358 · Cited by 40 · see citing works
Analysis of 57,148 Transmissions by Remote Monitoring of Implantable Cardioverter Defibrillators
Theuns, D. A. M. J., Rivero‐Ayerza, M., Knops, P., Res, J., & Jordaens, L. J. L. M. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02230.x · Cited by 40 · see citing works
Assessment of a remote monitoring system for implantable cardioverter defibrillators
Masella, C., Zanaboni, P., Stasi, F. D., Gilardi, S., Ponzi, P., & Valsecchi, S. (2008) · Journal of Telemedicine and Telecare · doi:10.1258/jtt.2008.080202 · Cited by 37 · see citing works
Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands
de Cock, C. C., Elders, J., van Hemel, N. M., van den Broek, K., van Erven, L., de Mol, B. A. J. M., Talmon, J. L., Theuns, D. A. M. J., & de Voogt, W. (2012) · Netherlands Heart Journal · doi:10.1007/s12471-011-0239-5 · Cited by 34 · see citing works
Marcus, G. M., CHAN, D. W., & Redberg, R. F. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02971.x · Cited by 34 · see citing works
Remote Active Monitoring in Patients With Heart Failure (RAPID-RF): Design and Rationale
Saxon, L. A., BOEHMER, J. P., Neuman, S., & Mullin, C. M. (2007) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2006.12.004 · Cited by 33 · see citing works
Sophisticated Remote Implantable Cardioverter‐Defibrillator Follow‐Up: A Status Report
Schoenfeld, M. H., & REYNOLDS, D. W. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.09554.x · Cited by 33 · see citing works
Self-citationVersteeg, H., Pedersen, S. S., Mastenbroek, M. H., Redekop, W. K., Schwab, J. O., Mabo, P., & Meine, M. (2014) · Netherlands Heart Journal · doi:10.1007/s12471-014-0587-z · Cited by 32 · see citing works
Chen, J., Wilkoff, B. L., Choucair, W. K., Cohen, T. J., Crossley, G. H., Johnson, W. B., Mongeon, L., Serwer, G. A., & Sherfesee, L. (2008) · Trials · doi:10.1186/1745-6215-9-18 · Cited by 30 · see citing works
Self-citationRuvo, E. D., Sciarra, L., Martino, A. M., Rebecchi, M., Iulianella, R. V., Sebastiani, F., Fagagnini, A., Borrelli, A., Scarà, A., Grieco, D., et al. (2015) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-015-0067-4 · Cited by 30 · see citing works
Transparent sharing of digital health data: A call to action
Slotwiner, D. J., Tarakji, K. G., Al‐Khatib, S. M., PASSMAN, R. S., Saxon, L. A., Peters, N. S., McCall, D., Turakhia, M. P., Schaeffer, J., Mendenhall, G. S., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.04.042 · Cited by 29 · see citing works
A Review on Remote Monitoring Technology Applied to Implantable Electronic Cardiovascular Devices
Costa, P. D., Rodrigues, P. P., Reis, A. H., & Costa‐Pereira, A. (2010) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2010.0082 · Cited by 28 · see citing works
The follow-up of cardiac devices: what to expect for the future?
Stellbrink, C., & Trappe, H. (2007) · European Heart Journal Supplements · doi:10.1093/eurheartj/sum071 · Cited by 27 · see citing works
Hauser, R. G., Mugglin, A. S., Friedman, P. A., Kramer, D. B., Kallinen, L. M., McGriff, D. M., & Hayes, D. L. (2012) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.111.962621 · Cited by 27 · see citing works
Impact of Remote Monitoring on Clinical Outcomes
Varma, N., & Ricci, R. P. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12829 · Cited by 26 · see citing works
López-Villegas, A., Catalán-Matamoros, D., Robles‐Musso, E., & Peiró, S. (2015) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/ggi.12612 · Cited by 26 · see citing works
Antepartum Fetal Monitoring through a Wearable System and a Mobile Application
Signorini, M. G., Lanzola, G., Torti, E., Fanelli, A., & Magenes, G. (2018) · Technologies · doi:10.3390/technologies6020044 · Cited by 24 · see citing works
Varma, N. (2013) · EP Europace · doi:10.1093/europace/eut116 · Cited by 23 · see citing works
Andò, K., Koyama, J., Abe, Y., Sato, T., Shoda, M., Soga, Y., Nobuyoshi, M., Honda, T., Nakao, K., Terata, K., et al. (2011) · International Heart Journal · doi:10.1536/ihj.52.39 · Cited by 20 · see citing works
Remotely monitored inactivity due to COVID-19 lockdowns
Fagih, A. R. A., Onazi, M. A., Basiri, S. A., Alkaf, F., Dagriri, K., Hebaishi, Y. A., Samargandy, S., & Shengeiti, L. A. (2020) · Saudi Medical Journal · doi:10.15537/smj.2020.11.25449 · Cited by 19 · see citing works
Osca, J., Tello, M. J. S., Navarro, J., Cano, Ó., Raso, R., Castro, J. E., Olagüe, J., & Salvador, A. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)72071-8 · Cited by 19 · see citing works
Ottenberg, A. L., Swetz, K. M., Mueller, L. A., Gerhardson, S., & Mueller, P. S. (2013) · Heart & Lung · doi:10.1016/j.hrtlng.2013.03.002 · Cited by 19 · see citing works
Remote detection of incessant slow VT with an ICD capable of home monitoring
SIAPLAOURAS, S. (2006) · EP Europace · doi:10.1093/europace/eul050 · Cited by 19 · see citing works
Device Features for Managing Patients with Heart Failure
Varma, N., & Wilkoff, B. L. (2011) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.12.005 · Cited by 18 · see citing works
Impact of COVID-19 Pandemic on Cardiac Electronic Device Management and Role of Remote Monitoring
Magnocavallo, M., Vetta, G., Bernardini, A., Piro, A., Mei, M. C., Iorio, M. D., Mariani, M. V., Rocca, D. G. D., Severino, P., Quaglione, R., et al. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.10.010 · Cited by 18 · see citing works
Characteristics of Sprint Fidelis lead failure.
Beukema, R. J., Misier, A. R. R., Delnoy, P. P. H. M., Smit, J. J. J., & Elvan, A. (2010) · PubMed Central · Cited by 18 · see citing works
Perings, C. A., Klein, G. G., Toft, E., Moro, C., Klug, D., Böcker, D., Trappe, H., & Korte, T. (2006) · EP Europace · doi:10.1093/europace/eul009 · Cited by 18 · see citing works
Cronin, E. M., & Varma, N. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.18 · Cited by 17 · see citing works
López-Villegas, A., Catalán-Matamoros, D., López‐Liria, R., Enebakk, T., Thunhaug, H., & Lappegård, K. T. (2018) · BMC Geriatrics · doi:10.1186/s12877-018-0911-3 · Cited by 17 · see citing works
Leppert, F., Siebermair, J., Wesemann, U., Martens, E., Sattler, S. M., Scholz, S. M., Veith, S., Greiner, W., Rassaf, T., Kääb, S., et al. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01667-0 · Cited by 17 · see citing works
Pron, G. E., Ieraci, L., & Kaulback, K. (2012) · Europe PMC (PubMed Central) · Cited by 17 · see citing works
Costa, P. D., Reis, A. H., & Rodrigues, P. P. (2013) · Telemedicine and e-Health · doi:10.1089/tmj.2012.0064 · Cited by 16 · see citing works
López-Villegas, A., Catalán-Matamoros, D., Robles‐Musso, E., & Peiró, S. (2015) · Revista Española de Salud Pública · doi:10.4321/s1135-57272015000200004 · Cited by 16 · see citing works
Osca, J., Tello, M. J. S., Navarro, J., Cano, Ó., Raso, R., Castro, J. E., Olagüe, J., & Salvador, A. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)72653-2 · Cited by 16 · see citing works
Timmermans, I., Meine, M., Zitron, E., Widdershoven, J. W. M. G., Kimman, G., Prévôt, S., Rauwolf, T., Anselme, F., Szendey, I., Roldán, J. R., et al. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13123 · Cited by 16 · see citing works
Usefulness of Remote Monitoring in Cardiac Implantable Device Follow-Up
Stoepel, C., Boland, J. L., Busca, R., Saal, G., & Oliveira, M. (2009) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2009.0068 · Cited by 16 · see citing works
Remote Monitoring of Patients With Implanted Cardiac Devices
Kusumoto, F. M., & Goldschlager, N. (2010) · Clinical Cardiology · doi:10.1002/clc.20688 · Cited by 16 · see citing works
Lim, P., Lee, A., Chua, K., Lim, E., Chong, D. W. S., Tan, B., Ho, K., Teo, W. S., & Ching, C. (2016) · Singapore Medical Journal · doi:10.11622/smedj.2016120 · Cited by 16 · see citing works
Marzegalli, M., Landolina, M., Lunati, M., Perego, G. B., Pappone, A., Guenzati, G., Campana, C., Frigerio, M., Parati, G., Curnis, A., et al. (2009) · Trials · doi:10.1186/1745-6215-10-42 · Cited by 16 · see citing works
Implantable medical devices as agents and part of multiagent systems
Drew, T., & Gini, M. L. (2006) · Adaptive Agents and Multi-Agents Systems · doi:10.1145/1160633.1160930 · Cited by 15 · see citing works
Gramegna, L., Tomasi, C., Gasparini, G. M., Scaboro, G., Zanon, F., Boaretto, G., Tomei, R., & Tomasi, L. (2011) · EP Europace · doi:10.1093/europace/eur334 · Cited by 14 · see citing works
Zoppo, F., Facchin, D., Molon, G., Zanotto, G., Catanzariti, D., Rossillo, A., Baccillieri, S., MENARD, C., COMISSO, J., Gentili, A., et al. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12474 · Cited by 14 · see citing works
Pacemaker Remote Monitoring in the Pediatric Population: Is It A Real Solution?
Leoni, L., Padalino, M. A., Biffanti, R., Ferretto, S., Vettor, G., Corrado, D., Stellin, G., Milanesi, O., & Iliceto, S. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12600 · Cited by 14 · see citing works
Work burden with remote monitoring of implantable cardioverter defibrillator
Papavasileiou, L. P., Forleo, G. B., Panattoni, G., Schirripa, V., Minni, V., Magliano, G., Bellos, K., Santini, L., & Romeo, F. (2012) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e328354e3e1 · Cited by 14 · see citing works
Ricci, R. P., Pignalberi, C., Magris, B., Aquilani, S., Altamura, V., Morichelli, L., Porfili, A., Quarta, L., Saputo, F. A., & Santini, M. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9612-y · Cited by 13 · see citing works
Remote Surveillance of Implantable Cardiac Devices
Orlov, M. V., Szombathy, T., CHAUDHRY, G. M., & Haffajee, C. I. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02412.x · Cited by 13 · see citing works
Ahmed, I., Patel, A. S., BALGAARD, T. J., & Rosenfeld, L. E. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12798 · Cited by 13 · see citing works
Mittal, S., Movsowitz, C., & Varma, N. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2014.01.001 · Cited by 12 · see citing works
- Authors
- SCHOENFELD, M. H., COMPTON, S. J., MEAD, R. H., WEISS, D. N., SHERFESEE, L., ENGLUND, J., & MONGEON, L. R.
- Affiliations
- Yale University (US)
- Alaska Heart and Vascular Institute (US)
- Sequoia Hospital (US)
- Medtronic (United States) (US)
- Corresponding author
- SCHOENFELD, MARK H.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2004-05-25
- Volume
- 27
- Issue
- 6p1
- Pages
- 757-763
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2158824883
- Cited by
- 194
- References
- 11
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 2 · 2018: 6 · 2017: 4 · 2016: 6 · 2015: 10 · 2014: 7 · 2013: 17 · 2012: 17
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Pacing and Clinical Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- implantable cardioverter-defibrillator, remote monitoring, atrial fibrillation detection, atrial undersensing, ventricular tachycardia, antiarrhythmic efficacy, ease of use
- MeSH terms
- Adult, Aged, Aged, 80 and over, Anti-Arrhythmia Agents, Atrial Fibrillation, Computer Communication Networks, Computer Systems, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Telemetry, Telephone, Death, Sudden, Cardiac, Defibrillators, Implantable, Tachycardia, Ventricular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review