Indications for the use of diagnostic implantable and external ECG loop recorders
The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Abstract
ECG loop recorders have a retrospective (loop) memory which continuously records and deletes the patient's ECG. They include a patient-activation function that allows the patient to activate ECG storage as a result of symptoms and an auto-activation feature that allows the capture of arrhythmic events without relying on patient compliance or perception of symptoms. Loop recorder devices can be both implantable (ILR) and external (ELR). Table 1 summarizes the characteristics of the most common diagnostic loop recorders. The retrospective memory differentiates loop recorders from prospective-only event recorders. While event recorders have some usefulness in patients with intermittent palpitations, they have no indication to detect syncope. Most common implantable and external loop recorders a, coming soon (not yet available); b, mobile cardiac outpatient telemetry; c, depends on Memory Card capacity. *Monitoring duration is determined by the battery longevity for implantable devices and by average maximum patients' compliance for external devices. Most common implantable and external loop recorders a, coming soon (not yet available); b, mobile cardiac outpatient telemetry; c, depends on Memory Card capacity. *Monitoring duration is determined by the battery longevity for implantable devices and by average maximum patients' compliance for external devices. Knowledge of what occurs during a spontaneous event is the ideal gold standard for evaluation. Patients with infrequent short-duration transient symptoms, recurring over weeks or months, are unlikely to be diagnosed by conventional Holter monitoring, since the likelihood of symptom-ECG correlation is very low. Consideration should be given to patient-activated event recording in such patients, but this technique has important limitations that might prevent a successful ECG recording of the event, especially for those with syncope, as it implies the activation of recording by the patients once the patient has already recovered consciousness. In such circumstances, consideration should be given to implantable and external ECG loop recorders. It is likely that loop recorders will become increasingly important, and their use will increasingly be appropriate instead of, or before, many current conventional investigations. This early loop recorder approach implies, on the one hand, the need for careful initial risk stratification in order to exclude from such a strategy patients with potential life-threatening conditions that require immediate hospitalization or intensive evaluation and treatment. On the other hand, as a general rule ECG loop recorders are indicated only when there is a high pre-test probability of identifying an heart rhythm abnormality responsible of symptoms. These conditions will be discussed in the document. Ultimately, technology may allow recording of multiple signals in addition to the ECG (e.g. blood flow or pressure, EEG, etc.) and the automatic immediate wireless transmission of pertinent data to a central monitoring station. Such advances will permit greater emphasis on the documenting and characterizing of spontaneous episodes. Conversely, they will result in less reliance for current diagnostic testing techniques that are largely designed to assess susceptibility to the provocation of syncope or palpitations in the laboratory. The Task Force has classified and ranked the usefulness or efficacy of the recommended procedure and/or treatments and the level of evidence as indicated in the tables below: The Task force was unable to give formal recommendations for non-established indications, i.e. atrial fibrillation and risk stratification, due to the lack of sufficient trial-based evidence. In these fields, loop recorders remain very interesting research tools. Clinical evaluation is enough to establish a likely mechanism of syncope in the majority of patients Exclude high-risk patients, i.e. those with a clear indication for ICD, pacemaker, or other treatments independent of a definite diagnosis of the cause of syncope Be aware that the pre-test selection of the patients influences the subsequent findings. Include patients with a high likelihood of arrhythmic events Include patients with a high probability of recurrence of syncope in a reasonable time period Due to the unpredictability of syncope recurrence, be prepared to wait for a substantial time before obtaining such a correlation Your ideal goal should be to obtain a correlation ECG and are Clinical evaluation is enough to establish a likely mechanism of syncope in the majority of patients Exclude high-risk patients, i.e. those with a clear indication for ICD, pacemaker, or other treatments independent of a definite diagnosis of the cause of syncope Be aware that the pre-test selection of the patients influences the subsequent findings. Include patients with a high likelihood of arrhythmic events Include patients with a high probability of recurrence of syncope in a reasonable ti
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The gold standard of diagnosis remains the correlation of a spontaneous event with a specific ECG finding,9”
From Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry (2011) · cites this paper as [9]
In the citing paper
“Presyncope was much less likely to be associated with an arrhythmia than syncope.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [179]
In the citing paper
“In pooled data from nine studies 179 performed in 506 patients with unexplained syncope at the end of complete negative work-up, a correlation between syncope and ECG was found in 176 patients (35%); of these, 56% had asystole (or bradycardia in a few cases) at the time of the recorded event, 11% had tachycardia, and 33% had no arrhythmia.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [179]
Citations
Cites
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Incidence and Prognosis of Syncope
Soteriades, E. S., Evans, J. C., Larson, M. G., Chen, M. H., Chen, L., Benjamin, E. J., & Levy, D. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012407 · Cited by 1,364 · cited 1×
“1 in men aged 70–79 years.(1) However, only one-third of these subjects present in a clinical setting and an even smaller proportion deserve some specialized evaluation.”
BackgroundCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951 · cited 1×
“The meaning of these findings is in accordance and reinforced by similar conclusions made with other forms of prolonged ECG monitoring and reported in current guidelines.(2,27) Using the criteria of an asystole .”
ResultSelf-citationGuidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Self-citationGuidelines on management (diagnosis and treatment) of syncope-update 2004. Executive Summary.
Brignole, M., Alboni, P., Benditt, D. G., Bergfeldt, L., Blanc, J., Thomsen, P. E. B., van Dijk, J. G., Fitzpatrick, A. P., Hohnloser, S. H., Janoušek, J., et al. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.09.004 · Cited by 613
Self-citationHindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y.-G., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 480
Sacher, F., Probst, V., Maury, P., Babuty, D., Mansourati, J., Komatsu, Y., Marquie, C., Rosa, A., Diallo, A., Cassagneau, R., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.001941 · Cited by 448
Misdiagnosis of epilepsy: many seizure-like attacks have a cardiovascular cause
Zaidi, A., Clough, P., Cooper, P., Scheepers, B., & Fitzpatrick, A. P. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00700-2 · Cited by 422
Sauer, A. J., Moss, A. J., McNitt, S., Peterson, D. R., Zareba, W., Robinson, J. L., Qi, M., Goldenberg, I., Hobbs, J. B., Ackerman, M. J., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.057 · Cited by 419
Venice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Capucci, A., Santini, M., Padeletti, L., Gulizia, M., Botto, G., Boriani, G., Ricci, R., Favale, S., Zolezzi, F., Di Belardino, N., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 401
Self-citationCardiac arrhythmias in focal epilepsy: a prospective long-term study
Rugg-Gunn, F. J., Simister, R. J., Squirrell, M., Holdright, D. R., & Duncan, J. S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17594-6 · Cited by 384
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Self-citationMechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators (2001) · Circulation · doi:10.1161/hc3601.095708 · Cited by 378
Self-citationBrignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi842 · Cited by 376 · cited 3×
“the initial evaluation, either positive or negative response during tilt testing, in order to capture an asystolic event when cardiac pacing would be justified by the severity and unpredictability of symptoms and lack of alternative therapies.(7) † Diagnosis of syncope not established, just suspected:”
BackgroundMethodInfluentialSelf-citationThe Prevalence of Symptoms in Medical Outpatients and the Adequacy of Therapy
Arrington, M. E. (1990) · Archives of Internal Medicine · doi:10.1001/archinte.1990.00040031685016 · Cited by 367
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Prevention of atrial fibrillation after cardioversion: results of the PAFAC trial
FETSCH, T. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.04.015 · Cited by 334
Mechanism of syncope in patients with bundle branch block and negative electrophysiological test
Brignole, M., Menozzi, C., Moya, A., Garcia-Civera, R., Mont, L., Alvarez, M., Errazquin, F., Beiras, J., Bottoni, N., Donateo, P., et al. (2001) · Circulation · doi:10.1161/hc4201.097837 · Cited by 328 · cited 1×
“† the patients with an established indication for implantable cardioverter-defibrillator (ICD) implantation according to guidelines ( 6 ) should receive this therapy upfront.”
BackgroundSelf-citationKirchhof, P., Auricchio, A., Bax, J., Crijns, H., Camm, J., Diener, H.-C., Goette, A., Hindricks, G., Hohnloser, S., Kappenberger, L., et al. (2007) · Europace · doi:10.1093/europace/eum191 · Cited by 293 · cited 2×
“† In rhythm control trials, the precise determination of freedom form AF is a crucial outcome parameter and a prerequisite for establishing new therapeutic strategies.(66) † From a clinical point of view, it is desirable to correlate symptoms with corresponding ECG findings especially when the nature of symptoms is mu…”
BackgroundSelf-citationSacher, F., Probst, V., Iesaka, Y., Jacon, P., Laborderie, J., Mizon-Gérard, F., Mabo, P., Reuter, S., Lamaison, D., Takahashi, Y., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.628537 · Cited by 293
Comparison of continuous versus intermittent monitoring of atrial arrhythmias
Ziegler, P. D., Koehler, J. L., & Mehra, R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.030 · Cited by 282 · cited 1×
“toring intensity, no more than about 70% of all AF recurrences will be detected.(74,78)”
BackgroundHuikuri, H. V., Raatikainen, M. J. P., Moerch-Joergensen, R., Hartikainen, J., Virtanen, V., Boland, J., Anttonen, O., Hoest, N., Boersma, L. V. A., Platou, E. S., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn537 · Cited by 264
Self-citationKinlay, S., Leitch, J. W., Neil, A., Chapman, B. L., Hardy, D. B., & Fletcher, P. J. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_1-199601010-00003 · Cited by 245
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
Sarkozy, A., Boussy, T., Kourgiannides, G., Chierchia, G.-B., Richter, S., De Potter, T., Geelen, P., Wellens, F., Dingena Spreeuwenberg, M., & Brugada, P. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl450 · Cited by 231
The clinical impact of implantable loop recorders in patients with syncope
Farwell, D. J., Freemantle, N., & Sulke, N. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi602 · Cited by 219
Self-citationThe etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Circulation · doi:10.1161/01.cir.100.8.886 · Cited by 215
Mechanism of syncope in patients with heart disease and negative electrophysiologic test
Menozzi, C., Brignole, M., Garcia-Civera, R., Moya, A., Botto, G., Tercedor, L., Migliorini, R., & Navarro, X. (2002) · Circulation · doi:10.1161/01.cir.0000018125.31973.87 · Cited by 204
Self-citationEvaluation and outcomes of patients with palpitations
Weber, B. E., & Kapoor, W. N. (1996) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)89451-x · Cited by 196 · cited 1×
“In several cases, especially in patients with infrequent symptoms, a diagnosis is difficult to establish in spite of careful clinical evaluation that includes standard ECG and Holter monitoring.(50) The M.”
BackgroundROTHMAN, S. A., LAUGHLIN, J. C., SELTZER, J., WALIA, J. S., BAMAN, R. I., SIOUFFI, S. Y., SANGRIGOLI, R. M., & KOWEY, P. R. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00729.x · Cited by 194
Kottkamp, H., Tanner, H., Kobza, R., Schirdewahn, P., Dorszewski, A., Gerds-Li, J.-H., Carbucicchio, C., Piorkowski, C., & Hindricks, G. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.049 · Cited by 191 · cited 8×
“Extending the duration of Holter recordings from 24 h to 7 days clearly enhanced the sensitivity of diagnosing recurrent AF.(74)”
BackgroundInfluentialGuidelines on management (diagnosis and treatment) of syncope—update 2004
Brignole, M., Alboni, P., & Benditt, D. G. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.02.024 · Cited by 189
Self-citationPaul, M., Gerss, J., Schulze-Bahr, E., Wichter, T., Vahlhaus, C., Wilde, A. A. M., Breithardt, G., & Eckardt, L. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm116 · Cited by 187
Evaluation of patients with palpitations
Zimetbaum, P., & Josephson, M. E. (1998) · New England Journal of Medicine · doi:10.1056/nejm199805073381907 · Cited by 172
Sivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00233-x · Cited by 160
Recurrent Unexplained Palpitations (RUP) Study
Giada, F., Gulizia, M., Francese, M., Croci, F., Santangelo, L., Santomauro, M., Occhetta, E., Menozzi, C., & Raviele, A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.036 · Cited by 158 · cited 4×
“Few studies are available on the use of ILR in patients with unexplained palpitations.(63) In the RUP (Recurrent Unexplained Palpitations) study, 50 patients were enrolled with infrequent ( 1 episode/month) and sustained (.”
BackgroundResultInfluentialVASAMREDDY, C. R., DALAL, D., DONG, J., CHENG, A., SPRAGG, D., LAMIY, S. Z., MEININGER, G., HENRIKSON, C. A., MARINE, J. E., BERGER, R., et al. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00359.x · Cited by 157 · cited 1×
“ance is poor when patients are asked to use ELRs for too long.(80) Such a limited recording period, however, is not adequate for long-term follow-up of rhythm control therapy in”
BackgroundSuppression of paroxysmal atrial tachyarrhythmias—results of the SOPAT trial
PATTEN, M., MAAS, R., BAUER, P., LUDERITZ, B., SONNTAG, F., DLUZNIEWSKI, M., HATALA, R., OPOLSKI, G., MULLER, H., & MEINERTZ, T. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.06.014 · Cited by 157
Brignole, M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl164 · Cited by 145
Self-citationThe Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Zimetbaum, P. J., & Josephson, M. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-10-199905180-00020 · Cited by 139
Zimetbaum, P. J., Kim, K. Y., Josephson, M. E., Goldberger, A. L., & Cohen, D. J. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-11-199806010-00002 · Cited by 133
SOLANO, A. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.05.013 · Cited by 122 · cited 4×
“An increased incidence of bradycardia with advancing age was also noted by Krahn et al.23 Solano et al.8 estimated that about 28% of patients with unexplained syncope at the end of a conventional work-up (which corresponds to 5% of all patients referred for evaluation to a tertiary syncope facility) ultimately have an…”
BackgroundInfluentialAn Implantable Loop Recorder Study of Highly Symptomatic Vasovagal Patients
Deharo, J.-C., Jego, C., Lanteaume, A., & Djiane, P. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.043 · Cited by 110 · cited 1×
“This classification has become widely used and validated by others.(16,35,36) The ISSUE classification has some pathophysiological implications, which are helpful to distinguish different types of arrhythmic syncope and have potentially different diagnostic, therapeutic, and prognostic implications.”
MethodPIORKOWSKI, C., KOTTKAMP, H., TANNER, H., KOBZA, R., NIELSEN, J. C., ARYA, A., & HINDRICKS, G. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00245.x · Cited by 110 · cited 1×
“However, for detection of AF recurrences, 1 min daily transtelephonic monitoring yields similar detection rates as regular 24 h/month Holter ECG monitoring.(69,71,75) Therefore, the current consensus statements on rhythm control therapy in AF(66,76,77) recommend to detect asymptomatic AF by regular 1–7 day Holter moni…”
MethodBhandari, A. K., Anderson, J. L., Gilbert, E. M., Alpert, B. L., Henthorn, R. W., Waldo, A. L., Cullen, M. T., Hawkinson, R. W., & Pritchett, E. L. C. (1992) · American Heart Journal · doi:10.1016/0002-8703(92)90601-q · Cited by 108
BRIGNOLE, M., MOYA, A., MENOZZI, C., GARCIACIVERA, R., & SUTTON, R. (2005) · Europace · doi:10.1016/j.eupc.2004.11.001 · Cited by 106 · cited 1×
“Classification of responses Because of the heterogeneity of findings and the wide variety of rhythm disturbances recorded with the ILR at the time of syncope, the ISSUE investigators have proposed a classification that groups the observations into homogeneous patterns in order to define an acceptable standard, useful…”
MethodSelf-citationBrown, A. P., Dawkins, K. D., & Davies, J. G. (1987) · Heart · doi:10.1136/hrt.58.3.251 · Cited by 96
Clinical Implications of Various Follow Up Strategies After Catheter Ablation of Atrial Fibrillation
Arya, A., Piorkowski, C., Sommer, P., Kottkamp, H., & Hindricks, G. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00693.x · Cited by 94
Value of the implantable loop recorder for the management of patients with unexplained syncope
Boersma, L. (2004) · Europace · doi:10.1016/j.eupc.2003.09.006 · Cited by 87
Heart Rhythm During Syncope and Presyncope: Results of Implantable Loop Recorders
NIEROP, P. R., VAN MECHELEN, R., VAN ELSÄCKER, A., LUIJTEN, R. H. M., & ELHENDY, A. (2000) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2000.01532.x · Cited by 86
Maggi, R., Menozzi, C., Brignole, M., Podoleanu, C., Iori, M., Sutton, R., Moya, A., Giada, F., Orazi, S., & Grovale, N. (2007) · EP Europace · doi:10.1093/europace/eum092 · Cited by 79
Self-citationUtility of Patient-Activated Cardiac Event Recorders in General Clinical Practice
Zimetbaum, P., Kim, K. Y., Ho, K. K. L., Zebede, J., Josephson, M. E., & Goldberger, A. L. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00766-7 · Cited by 77
Utility of Implantable Loop Recorder (Reveal Plus®) in the Diagnosis of Unexplained Syncope
LOMBARDI, F., CALOSSO, E., MASCIOLI, G., MARANGONI, E., DONATO, A., ROSSI, S., PALA, M., FOTI, F., & LUNATI, M. (2005) · Europace · doi:10.1016/j.eupc.2004.09.003 · Cited by 76
Detection of asymptomatic arrhythmias in unexplained syncope
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2004) · American Heart Journal · doi:10.1016/j.ahj.2004.01.024 · Cited by 76
BRIGNOLE, M., MENOZZI, C., MAGGI, R., SOLANO, A., DONATEO, P., BOTTONI, N., LOLLI, G., QUARTIERI, F., CROCI, F., & ODDONE, D. (2005) · Europace · doi:10.1016/j.eupc.2005.02.116 · Cited by 76
Self-citationBrugada, P., Andries, E., Gürsoy, S., & Brugada, J. (1993) · The Lancet · doi:10.1016/0140-6736(93)91155-f · Cited by 71
Predicting the Outcome of Patients with Unexplained Syncope Undergoing Prolonged Monitoring
KRAHN, A. D., KLEIN, G. J., FITZPATRICK, A., SEIDL, K., ZAIDI, A., SKANES, A., & YEE, R. (2002) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2002.00037.x · Cited by 69 · cited 3×
“An increased incidence of bradycardia with advancing age was also noted by Krahn et al.23 Solano et al.8 estimated that about 28% of patients with unexplained syncope at the end of a conventional work-up (which corresponds to 5% of all patients referred for evaluation to a tertiary syncope facility) ultimately have an…”
BackgroundMechanism of syncope in patients with positive adenosine triphosphate tests
Donateo, P., Brignole, M., Menozzi, C., Bottoni, N., Alboni, P., Dinelli, M., Del Rosso, A., Croci, F., Oddone, D., Solano, A., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02621-9 · Cited by 68
Self-citationInsertable Loop Recorder Use for Detection of Intermittent Arrhythmias
KRAHN, A. D., KLEIN, G. J., SKANES, A. C., & YEE, R. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00502.x · Cited by 66 · cited 1×
“Technical aspects Although auto-activation feature increases the diagnostic yield, this feature can be compromised by the detection of false arrhythmias(28,29) and the missed detection of true arrhythmias.(30,31) Documented causes of false arrhythmia storage in ILRs include”
BackgroundImplications of mechanism of bradycardia on response to pacing in patients with unexplained syncope
Sud, S., Klein, G. J., Skanes, A. C., Gula, L. J., Yee, R., & Krahn, A. D. (2007) · EP Europace · doi:10.1093/europace/eum020 · Cited by 66 · cited 1×
“This classification has become widely used and validated by others.(16,35,36) The ISSUE classification has some pathophysiological implications, which are helpful to distinguish different types of arrhythmic syncope and have potentially different diagnostic, therapeutic, and prognostic implications.”
MethodSCHUCHERT, A., MAAS, R., KRETZSCHMAR, C., BEHRENS, G., KRATZMANN, I., & MEINERTZ, T. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00277.x · Cited by 62
Hoffmann, E., Sulke, N., Edvardsson, N., Ruiter, J., Lewalter, T., Capucci, A., Schuchert, A., Janko, S., & Camm, J. (2006) · Circulation · doi:10.1161/circulationaha.105.568568 · Cited by 61
Self-citationExternal loop recorders: determinants of diagnostic yield in patients with syncope
Gula, L. J., Krahn, A. D., Massel, D. R., Skanes, A. C., Yee, R. K., & Klein, G. J. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.10.036 · Cited by 58 · cited 1×
“This time frame is usually the maximum that a patient can comply; shorter duration yield lower diagnostic yield.(41) ELR can also be used if the clinical presentation suggests that documenting an ECG during presyncope will elucidate the mechanism of syncope.”
BackgroundHow Revealing Are Insertable Loop Recorders in Pediatrics?
FRANGINI, P. A., CECCHIN, F., JORDAO, L., MARTUSCELLO, M., ALEXANDER, M. E., TRIEDMAN, J. K., WALSH, E. P., & BERUL, C. I. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.00995.x · Cited by 57
Temporal patterns of paroxysmal atrial fibrillation following DDDR pacemaker implantation
Gillis, A. M., & Rose, M. S. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00792-x · Cited by 55 · cited 2×
“Cardiac Arrhythmias and Risk Stratification after Acute Myocardial Infarction (CARISMA) study(84) was designed to document the incidence and prognostic significance of cardiac arrhythmias after acute myocardial infarction in patients with left ventricular ejection fraction (LVEF) 40%.(65) In this study, significant br…”
BackgroundMethodPezawas, T., Stix, G., Kastner, J., Schneider, B., Wolzt, M., & Schmidinger, H. (2008) · Heart · doi:10.1136/hrt.2007.116616 · Cited by 52
Improved Arrhythmia Detection in Implantable Loop Recorders
Brignole, M., Bellardine, C. L., Thomsen, P. E. B., Sutton, R., Moya‐Mitjans, À., STADLER, R. W., Cao, J. J., Messier, M., & Huikuri, H. V. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01156.x · Cited by 48 · cited 1×
“6% of patients had one or more inappropriate episodes.(33) Even if most of these misdetections can easily be recognized, they can potentially determine misdiagnosis with consequent administration of useless therapies.”
BackgroundSelf-citationPredictive value of presyncope in patients monitored for assessment of syncope
Krahn, A. D., Klein, G. J., Yee, R. K., & Skanes, A. C. (2001) · American Heart Journal · doi:10.1067/mhj.2001.114196 · Cited by 47
Sensing issues related to the clinical use of implantable loop recorders
Chrysostomakis, S. I., Klapsinos, N. C., Simantirakis, E. N., Marketou, M. E., Kambouraki, D. C., & Vardas, P. E. (2003) · EP Europace · doi:10.1053/eupc.2002.0301 · Cited by 47
Self-citationThe use of an implantable loop recorder in the investigation of unexplained syncope in older people
Armstrong, V. L. (2003) · Age and Ageing · doi:10.1093/ageing/32.2.185 · Cited by 47
Hoefman, E., van Weert, H. C., Reitsma, J. B., Koster, R. W., & Bindels, P. J. (2005) · Family Practice · doi:10.1093/fampra/cmi048 · Cited by 46
Kothari, D., Riddell, F., Smith, W., Voss, J., & Skinner, J. R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.018 · Cited by 42
Pierre, B., Fauchier, L., Breard, G., Marie, O., Poret, P., & Babuty, D. (2008) · Europace · doi:10.1093/europace/eun039 · Cited by 42 · cited 2×
“50% in the study of Pierre.(14) While patients with and without structural heart disease had similar incidence of syncope recurrence, its mechanism was different: patients with structural heart disease more frequently had paroxysmal AV block and tachyarrhythmias and patients without structural heart disease more frequ…”
BackgroundMoya, A., Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Wieling, W., Andresen, D., Benditt, D. G., Garcia-Sacristán, J. F., Beiras, X., et al. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.07.043 · Cited by 38
Self-citationArrhythmia Detection by Patient and Auto-Activation in Implantable Loop Recorders
Ng, E., Stafford, P. J., & Ng, G. A. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000019268.95018.91 · Cited by 38 · cited 1×
“undersensing related to sudden reductions in R-wave signal amplitude during both normal sinus rhythm(32) and arrhythmias,(31) undersensing by transient loss of ECG signal related to device amplifier saturation,(29) T-wave(28) and myopotential.(28) A systematic analysis of”
BackgroundHoefman, E., van Weert, H. C., Boer, K. R., Reitsma, J., Koster, R. W., & Bindels, P. J. (2006) · Family Practice · doi:10.1093/fampra/cml065 · Cited by 38
Transtelephonic electrocardiographic transmission for management of cardiac arrhythmias
Antman, E. M., Ludmer, P. L., McGowan, N., Bosak, M., Friedman, P. L., Alvarez, P., Then, V., & Nevins, D. (1986) · The American Journal of Cardiology · doi:10.1016/s0002-9149(86)80031-5 · Cited by 37
901–45 Etiology of Syncope in Patients with Negative Electrophysiologic and Tilt Table Testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. K. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)91522-y · Cited by 37
Reiffel, J. A., Schulhof, E., Joseph, B., Severance, E., Wyndus, P., & McNamara, A. (1991) · Journal of Electrocardiology · doi:10.1016/0022-0736(91)90007-9 · Cited by 36 · cited 1×
“In clinical studies in which patients with at least weekly recurrence of palpitations, ELRs as well as event recorders showed a consistent diagnostic power of 66–75%, superior to that of conventional Holter monitoring.(52,57) – 62 Owing to the nature of short-lasting palpitations in low-risk patients, the most frequen…”
BackgroundComponents of clinical trials for vasovagal syncope
Sheldon, R. (2001) · Europace · doi:10.1053/eupc.2001.0168 · Cited by 28
Guía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya‐Mitjans, À., Sutton, R., Ammirati, F., Blanc, J., Brignole, M., Dahm, J. B., Deharo, J., Gajek, J. J., Gjesdal, K., Krahn, A. D., et al. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)73132-x · Cited by 27
Self-citationImplantable loop recorder undersensing mimicking complete heart block
Chrysostomakis, S. I., SIMANTIRAKIS, E. N., Marketou, M. E., & Vardas, P. (2002) · EP Europace · doi:10.1053/eupc.2002.0229 · Cited by 21
Utility of event loop recorders for the management of arrhythmias in young ambulatory patients
Martinez, T., & Sztajzel, J. M. (2004) · International Journal of Cardiology · doi:10.1016/j.ijcard.2003.11.004 · Cited by 20
Bennett, G. (1988) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(88)80138-0 · Cited by 18
Diagnostic Utility of Memory Equipped Transtelephonic Monitors
Schmidt, S. B., & Jain, A. C. (1988) · The American Journal of the Medical Sciences · doi:10.1097/00000441-198811000-00002 · Cited by 17
MONTENERO, A. S., Quayyum, A., Franciosa, P., Mangiameli, D., Antonelli, A., Barbieri, L., Bruno, N., Zumbo, F., & Vimercati, M. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000026914.04770.9a · Cited by 17 · cited 7×
“However, the reliability of the counter data depends on the correct detection of AF.”
BackgroundInfluentialDiagnostic management of patients with palpitations of unknown origin.
Giada, F., & Raviele, A. (2004) · PubMed · Cited by 15
SCHWARTZMAN, D. S., Blagev, D., BROWN, M. L., & Mehra, R. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00342.x · Cited by 15 · cited 8×
“However, the reliability of the counter data depends on the correct detection of AF.”
BackgroundInfluentialMoya, A. G., Sutton, R. B., Ammirati, F., et al. (2009) · Data Archiving and Networked Services (DANS) · Cited by 15
Self-citation
Research works printed but not linked: 7
- 2008, Heart, 94, 17
- 2005, American heart journal, 148, 326
- 1998, Annals of Internal Medicine, 28, 890
- 1988, The American journal of cardiology, 58, 1021
- 1999, Annals of Internal Medicine, 150, 848
- Giada, 2004, Italian heart journal : official journal of the Italian Federation of Cardiology, 5, 581
- 2004, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 10, 2111
Cited by
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
Self-citation2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Self-citationDeveloped in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citation2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citationGuidelines for the management of atrial fibrillation
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · EP Europace · doi:10.1093/europace/euq350 · Cited by 1,747
Self-citation
Metadata
- Authors
- Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, Auricchio, A., Lip, G. Y. H., Almendral, J., Kirchhof, P., Aliot, E., Gasparini, M., Braunschweig, F., Reviewers, D., Lip, G. Y. H., Almendral, J., Kirchhof, P., & Botto, G. L.
- Corresponding author
- Brignole, M.
- ORCID
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-04-28
- Volume
- 11
- Issue
- 5
- Pages
- 671-687
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W1994609836
- Cited by
- 362
- References
- 94
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 12 · 2023: 15 · 2022: 12 · 2021: 29 · 2020: 24 · 2019: 17 · 2018: 25 · 2017: 22 · 2016: 28 · 2015: 27 · 2014: 29 · 2013: 28 · 2012: 14
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- EP Europace (publishedVersion)
- PubMed (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Pure Amsterdam UMC (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- implantable loop recorder, external loop recorder, syncope, auto-activation, risk stratification, Holter monitoring, diagnostic indications, cardiac monitoring devices, event data recorders, battery life
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Humans, Monitoring, Physiologic, Syncope
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.