Indications for the use of diagnostic implantable and external ECG loop recorders
The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Abstract
ECG loop recorders have a retrospective (loop) memory which continuously records and deletes the patient's ECG. They include a patient-activation function that allows the patient to activate ECG storage as a result of symptoms and an auto-activation feature that allows the capture of arrhythmic events without relying on patient compliance or perception of symptoms. Loop recorder devices can be both implantable (ILR) and external (ELR). Table 1 summarizes the characteristics of the most common diagnostic loop recorders. The retrospective memory differentiates loop recorders from prospective-only event recorders. While event recorders have some usefulness in patients with intermittent palpitations, they have no indication to detect syncope. Most common implantable and external loop recorders a, coming soon (not yet available); b, mobile cardiac outpatient telemetry; c, depends on Memory Card capacity. *Monitoring duration is determined by the battery longevity for implantable devices and by average maximum patients' compliance for external devices. Most common implantable and external loop recorders a, coming soon (not yet available); b, mobile cardiac outpatient telemetry; c, depends on Memory Card capacity. *Monitoring duration is determined by the battery longevity for implantable devices and by average maximum patients' compliance for external devices. Knowledge of what occurs during a spontaneous event is the ideal gold standard for evaluation. Patients with infrequent short-duration transient symptoms, recurring over weeks or months, are unlikely to be diagnosed by conventional Holter monitoring, since the likelihood of symptom-ECG correlation is very low. Consideration should be given to patient-activated event recording in such patients, but this technique has important limitations that might prevent a successful ECG recording of the event, especially for those with syncope, as it implies the activation of recording by the patients once the patient has already recovered consciousness. In such circumstances, consideration should be given to implantable and external ECG loop recorders. It is likely that loop recorders will become increasingly important, and their use will increasingly be appropriate instead of, or before, many current conventional investigations. This early loop recorder approach implies, on the one hand, the need for careful initial risk stratification in order to exclude from such a strategy patients with potential life-threatening conditions that require immediate hospitalization or intensive evaluation and treatment. On the other hand, as a general rule ECG loop recorders are indicated only when there is a high pre-test probability of identifying an heart rhythm abnormality responsible of symptoms. These conditions will be discussed in the document. Ultimately, technology may allow recording of multiple signals in addition to the ECG (e.g. blood flow or pressure, EEG, etc.) and the automatic immediate wireless transmission of pertinent data to a central monitoring station. Such advances will permit greater emphasis on the documenting and characterizing of spontaneous episodes. Conversely, they will result in less reliance for current diagnostic testing techniques that are largely designed to assess susceptibility to the provocation of syncope or palpitations in the laboratory. The Task Force has classified and ranked the usefulness or efficacy of the recommended procedure and/or treatments and the level of evidence as indicated in the tables below: The Task force was unable to give formal recommendations for non-established indications, i.e. atrial fibrillation and risk stratification, due to the lack of sufficient trial-based evidence. In these fields, loop recorders remain very interesting research tools. Clinical evaluation is enough to establish a likely mechanism of syncope in the majority of patients Exclude high-risk patients, i.e. those with a clear indication for ICD, pacemaker, or other treatments independent of a definite diagnosis of the cause of syncope Be aware that the pre-test selection of the patients influences the subsequent findings. Include patients with a high likelihood of arrhythmic events Include patients with a high probability of recurrence of syncope in a reasonable time period Due to the unpredictability of syncope recurrence, be prepared to wait for a substantial time before obtaining such a correlation Your ideal goal should be to obtain a correlation ECG and are Clinical evaluation is enough to establish a likely mechanism of syncope in the majority of patients Exclude high-risk patients, i.e. those with a clear indication for ICD, pacemaker, or other treatments independent of a definite diagnosis of the cause of syncope Be aware that the pre-test selection of the patients influences the subsequent findings. Include patients with a high likelihood of arrhythmic events Include patients with a high probability of recurrence of syncope in a reasonable ti
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The gold standard of diagnosis remains the correlation of a spontaneous event with a specific ECG finding,9”
From Use of an implantable loop recorder to increase the diagnostic yield in unexplained syncope: results from the PICTURE registry (2011) · cites this paper as [9]
In the citing paper
“Presyncope was much less likely to be associated with an arrhythmia than syncope.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [179]
In the citing paper
“In pooled data from nine studies 179 performed in 506 patients with unexplained syncope at the end of complete negative work-up, a correlation between syncope and ECG was found in 176 patients (35%); of these, 56% had asystole (or bradycardia in a few cases) at the time of the recorded event, 11% had tachycardia, and 33% had no arrhythmia.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [179]
Citations
Cites
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Incidence and Prognosis of Syncope
Soteriades, E. S., Evans, J. C., Larson, M. G., Chen, M. H., Chen, L., Benjamin, E. J., & Levy, D. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012407 · Cited by 1,364 · cited 1×
“1 in men aged 70–79 years.(1) However, only one-third of these subjects present in a clinical setting and an even smaller proportion deserve some specialized evaluation.”
BackgroundCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951 · cited 1×
“The meaning of these findings is in accordance and reinforced by similar conclusions made with other forms of prolonged ECG monitoring and reported in current guidelines.(2,27) Using the criteria of an asystole .”
ResultSelf-citationGuidelines on Management (diagnosis and treatment) of syncope ? update 2004
(2004) · Europace · doi:10.1016/j.eupc.2004.08.008 · Cited by 652
Self-citationGuidelines on management (diagnosis and treatment) of syncope-update 2004. Executive Summary.
Brignole, M., Alboni, P., Benditt, D. G., Bergfeldt, L., Blanc, J., Thomsen, P. E. B., van Dijk, J. G., Fitzpatrick, A. P., Hohnloser, S. H., Janoušek, J., et al. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.09.004 · Cited by 613
Self-citationHindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y.-G., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 480
Sacher, F., Probst, V., Maury, P., Babuty, D., Mansourati, J., Komatsu, Y., Marquie, C., Rosa, A., Diallo, A., Cassagneau, R., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.001941 · Cited by 448
Misdiagnosis of epilepsy: many seizure-like attacks have a cardiovascular cause
Zaidi, A., Clough, P., Cooper, P., Scheepers, B., & Fitzpatrick, A. P. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00700-2 · Cited by 422
Research works printed but not linked: 7
- 2008, Heart, 94, 17
- 2005, American heart journal, 148, 326
- 1998, Annals of Internal Medicine, 28, 890
- 1988, The American journal of cardiology, 58, 1021
- 1999, Annals of Internal Medicine, 150, 848
- Giada, 2004, Italian heart journal : official journal of the Italian Federation of Cardiology, 5, 581
- 2004, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 10, 2111
Cited by
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
Self-citation2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Self-citationDeveloped in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citation2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citationGuidelines for the management of atrial fibrillation
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · EP Europace · doi:10.1093/europace/euq350 · Cited by 1,747
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., De Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martiın, A., et al. (2018) · Kardiologia Polska · doi:10.5603/kp.2018.0161 · Cited by 476
Self-citationHindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Self-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., Mahrholdt, H., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0212 · Cited by 341
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
“Intermittent loop recorders can be either external devices (“external loop recorder” or ELR) or implantable devices (“implantable loop recorder” or ILR) (Brignole et al., 2009).”
BackgroundMethodInfluentialGuía de práctica clínica para el diagnóstico y manejo del síncope (versión 2009)
Moya, Á., Sutton, R., Ammirati, F., Blanc, J.-J., Brignole, M., Dahm, J. B., Deharo, J.-C., Gajek, J., Gjesdal, K., Krahn, A., et al. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)73541-8 · Cited by 276
Self-citationEdvardsson, N., Frykman, V., van Mechelen, R., Mitro, P., Mohii-Oskarsson, A., Pasquie, J.-L., Ramanna, H., Schwertfeger, F., Ventura, R., Voulgaraki, D., et al. (2011) · Europace · doi:10.1093/europace/euq418 · Cited by 250
Kirchhof, P., Lip, G. Y. H., Van Gelder, I. C., Bax, J., Hylek, E., Kaab, S., Schotten, U., Wegscheider, K., Boriani, G., Brandes, A., et al. (2012) · Europace · doi:10.1093/europace/eur241 · Cited by 243
“Implantable subcutaneous devices can provide continuous cardiac rhythm monitoring in patients that do not require pacemakers or defibrillators.(182) The diagnostic accuracy of subcutaneous ECG monitors is good, but implanted monitors may not detect all episodes of AF picked up by conventional, manually analysed Holter…”
BackgroundSelf-citationStahrenberg, R., Weber-Krüger, M., Seegers, J., Edelmann, F., Lahno, R., Haase, B., Mende, M., Wohlfahrt, J., Kermer, P., Vollmann, D., et al. (2010) · Stroke · doi:10.1161/strokeaha.110.591958 · Cited by 213
JCS/JHRS 2019 Guideline on Non-Pharmacotherapy of Cardiac Arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Circulation Journal · doi:10.1253/circj.cj-20-0637 · Cited by 200
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Europace · doi:10.1093/europace/eur303 · Cited by 179
“A strong safety profile, the effectiveness, and a positive impact on resource utilizations in comparison with calendar-based in-office follow-up visits has been consistently and repeatedly demonstrated.(32,34,36,37,41)”
Self-citationJCS/JHRS 2019 guideline on non‐pharmacotherapy of cardiac arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12491 · Cited by 164
Shah, M. J., Silka, M. J., Silva, J. N. A., Balaji, S., Beach, C. M., Benjamin, M. N., Berul, C. I., Cannon, B. C., Cecchin, F., Cohen, M. I., et al. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.07.038 · Cited by 171
Raviele, A., Giada, F., Bergfeldt, L., Blanc, J. J., Blomstrom-Lundqvist, C., Mont, L., Morgan, J. M., Raatikainen, M. J. P., Steinbeck, G., Viskin, S., et al. (2011) · Europace · doi:10.1093/europace/eur130 · Cited by 149
“4 weeks) and when all other investigations, including external ambulatory ECG monitoring, prove to be negative.(66)”
BackgroundSelf-citationSavelieva, I., Fumagalli, S., Kenny, R. A., Anker, S. D., Bénétos, A., Boriani, G., Bunch, T. J., Dagres, N., Dubner, S., Fauchier, L., et al. (2023) · EP Europace · doi:10.1093/europace/euac123 · Cited by 146
“34–36 Antiarrhythmic medications may potentiate orthostatic intolerance, increase risk of bradycardia, contribute to other falls risk factors, such as impairment of attention/concentration, sleep impairment, electrolyte disturbance, or visual impairment.”
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.036 · Cited by 144
Chiang, C., Wu, T.-J., Ueng, K.-C., Chao, T., Chang, K., Wang, C.-C., Lin, Y., Yin, W., Kuo, J., Lin, W., et al. (2016) · Journal of the Formosan Medical Association · doi:10.1016/j.jfma.2016.10.005 · Cited by 140
Holter Monitoring and Loop Recorders: From Research to Clinical Practice
Galli, A., Ambrosini, F., & Lombardi, F. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.17.2 · Cited by 141
“ELRs can monitor the ECG for a maximum of 30 days.(1,2) An ELR can be connected to a belt around the chest, without the need for traditional electrodes.”
BackgroundMethodInfluentialKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Kenny, R. A., Brignole, M., Dan, G.-A., Deharo, J. C., van Dijk, J. G., Doherty, C., Hamdan, M., Moya, A., Parry, S. W., Sutton, R., et al. (2015) · Europace · doi:10.1093/europace/euv115 · Cited by 125
Self-citationDiagnosis, management, and outcomes of patients with syncope and bundle branch block
Moya, A., Garcia-Civera, R., Croci, F., Menozzi, C., Brugada, J., Ammirati, F., Del Rosso, A., Bellver-Navarro, A., Garcia-Sacristan, J., Bortnik, M., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr071 · Cited by 124
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P. F., Balsam, P., Baranchuk, A. M., Cantillon, D. J., Dilaveris, P., Dubner, S., El‐Sherif, N., et al. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12447 · Cited by 131
“Intermittent loop recorders can be either external devices (“external loop recorder” or ELR) or implantable devices (“implantable loop recorder” or ILR) (Brignole et al., 2009).”
BackgroundMethodInfluentialImplantable loop recorder in clinical practice
Bisignani, A., Bonis, S. D., Mancuso, L., Ceravolo, G., & Bisignani, G. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12142 · Cited by 126
Miniaturized Reveal LINQ insertable cardiac monitoring system: First-in-human experience
Pürerfellner, H., Sanders, P., Pokushalov, E., Di Bacco, M., Bergemann, T., & Dekker, L. R. C. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.02.030 · Cited by 96
“We report positive results with regard to (1) ease of implantation, (2) quality of ECGs obtained, (3) remote monitoring as assessed by daily transmissions, (4) absence of major complications, and (5) no significant device migration after a follow-up of 1 month.”
Locati, E. T., Moya, A., Oliveira, M., Tanner, H., Willems, R., Lunati, M., & Brignole, M. (2016) · Europace · doi:10.1093/europace/euv311 · Cited by 95
Self-citationSulke, N., Sugihara, C., Hong, P., Patel, N., & Freemantle, N. (2016) · Europace · doi:10.1093/europace/euv228 · Cited by 95
“Conventional Holter monitoring and external loop recorders are recognized to have low diagnostic yield.(2,3) Futile investigations and recurrent hospitalizations in these patients have significant health economic consequences.”
BackgroundSelf-citationSaklani, P., Krahn, A., & Klein, G. (2013) · Circulation · doi:10.1161/circulationaha.112.138396 · Cited by 89
“Furthermore, the time course of recurrence is unpredictable.(9,42)”
Current and Future Use of Insertable Cardiac Monitors
Giancaterino, S., Lupercio, F. A., Nishimura, M., & Hsu, J. C. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.06.001 · Cited by 91
Brignole, M., Ammirati, F., Arabia, F., Quartieri, F., Tomaino, M., Ungar, A., Lunati, M., Russo, V., Del Rosso, A., & Gaggioli, G. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv069 · Cited by 80
“Total number of syncopes in the year after implantation (%) 11 (5) 6 (5) 1 (2) 2 (7)”
BackgroundSelf-citationShah, M. J., Silka, M. J., Silva, J. N. A., Balaji, S., Beach, C. M., Benjamin, M. N., Berul, C. I., Cannon, B. C., Cecchin, F., Cohen, M. I., et al. (2021) · Cardiology in the Young · doi:10.1017/s1047951121003413 · Cited by 87
FURUKAWA, T., MAGGI, R., BERTOLONE, C., FONTANA, D., & BRIGNOLE, M. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02133.x · Cited by 77
“The diagnostic yield was independent of structural heart disease, bundle branch block, number of syncopes, age, and gender; the median time to diagnosis of ISSUE type 1 patients was shorter than that of the others (4 [2;10] vs.”
BackgroundSelf-citationNew-Onset Atrial Fibrillation After Cardiac Surgery: Pathophysiology, Prophylaxis, and Treatment
Ломиворотов, В. В., Efremov, S. M., Pokushalov, E. A., & Karaskov, A. M. (2015) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2015.08.003 · Cited by 78
The Reveal LINQ insertable cardiac monitor
Tomson, T. T., & Passman, R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.953059 · Cited by 72
“The European Heart Rhythm Association has also released a position paper on indications for the use of ICMs [15].”
BackgroundNÖLKER, G., MAYER, J., BOLDT, L., SEIDL, K., VAN DRIEL, V., MASSA, T., KOLLUM, M., BRACHMANN, J., DENEKE, T., HINDRICKS, G., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13089 · Cited by 69
Eitel, C., Husser, D., Hindricks, G., Frühauf, M., Hilbert, S., Arya, A., Gaspar, T., Wetzel, U., Bollmann, A., & Piorkowski, C. (2011) · EP Europace · doi:10.1093/europace/euq511 · Cited by 73
“rhythm control or the need for oral anticoagulation.(4) Several methods have been described to improve rhythm monitoring in AF patients.”
Syncope and paroxysmal atrioventricular block
Aste, M., & Brignole, M. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.03.008 · Cited by 79
“monitoring devices have increased the diagnostic yield [5,6].”
BackgroundSelf-citationMaines, M., Zorzi, A., Tomasi, G., Angheben, C., Catanzariti, D., Piffer, L., & Greco, M. D. (2017) · EP Europace · doi:10.1093/europace/eux187 · Cited by 71
Solbiati, M., Casazza, G., Dipaola, F., Barbic, F., Caldato, M., Montano, N., Furlan, R., Sheldon, R. S., & Costantino, G. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.12.128 · Cited by 65
“[4–7] For these reasons, implantable loop recorders (ILRs) have gained popularity and are suggested as an earlier tool in the diagnostic pathway of undetermined syncope.[8] ILRs are”
Long-term cardiac monitoring in older adults with unexplained falls and syncope
Bhangu, J., McMahon, C. G., Hall, P., Bennett, K., Rice, C., Crean, P., Sutton, R., & Kenny, R.-A. (2016) · Heart · doi:10.1136/heartjnl-2015-308706 · Cited by 63
Camm, A. J., Savelieva, I., Ho, S. Y., Lindsay, B. D., Nattel, S., & Shinagawa, K. (2009) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00044-2 · Cited by 62
Petkar, S., Hamid, T., Iddon, P., Clifford, A., Rice, N., Claire, R., McKee, D., Curtis, N., Cooper, P. N., & Fitzpatrick, A. P. (2012) · Europace · doi:10.1093/europace/eus185 · Cited by 60
“This rate of ECG/symptom correlation is higher than the 35% for patients presenting with unexplained syncope and 27% for patients with possible neurally mediated syncope,(16) but comparable to the 88% when used in highly selected patients.(16) In one other study,(17)”
ResultImplantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope
Solbiati, M., Costantino, G., Casazza, G., Dipaola, F., Galli, A., Furlan, R., Montano, N., & Sheldon, R. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011637.pub2 · Cited by 56
Podd, S. J., Sugihara, C., FURNISS, S. S., & Sulke, N. (2015) · EP Europace · doi:10.1093/europace/euv367 · Cited by 63
“The use of currently available ICMs in the long-term assessment of AF burden should be undertaken with caution.(12,24) This is not the case if the absence of AF is the trial or clinical endpoint as is the case in many trials evaluating AF ablation technologies.”
BackgroundMethodSelf-citationRuwald, M. H., Hansen, M. L., Lamberts, M., Hansen, C. M., Numé, A.-K., Vinther, M., Køber, L., Torp-Pedersen, C., Hansen, J., & Gislason, G. H. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.07.041 · Cited by 59
2020 Clinical practice guidelines for Hypertrophic cardiomyopathy
Габрусенко, С. А., Gudkova, A. Y., Koziolova, N. A., Alexandrova, S. А., Berseneva, M., Гордеев, М. Л., Sl, D., Zaklyazminskaya, E. V., Irtyuga, O. B., Kaplunova, V. Y., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4541 · Cited by 61
Daccarett, M., Jetter, T. L., Wasmund, S. L., Brignole, M., & Hamdan, M. H. (2011) · Europace · doi:10.1093/europace/eur201 · Cited by 58
Self-citationEffectiveness of remote monitoring in the management of syncope and palpitations
Furukawa, T., Maggi, R., Bertolone, C., Ammirati, F., Santini, M., Ricci, R., Giada, F., & Brignole, M. (2011) · Europace · doi:10.1093/europace/euq503 · Cited by 57
“Documented causes of false arrhythmia storage in ILRs include undersensing related to sudden reductions in R-wave signal amplitude during both normal sinus rhythm and arrhythmias, and undersensing due to transient loss of the ECG signal because of device amplifier saturation, T-wave, and myopotential.(2,20) In this st…”
BackgroundMethodSelf-citationLocati, E. T., Vecchi, A. M., Vargiu, S., Cattafi, G., & Lunati, M. (2014) · Europace · doi:10.1093/europace/eut337 · Cited by 53
“Thus, current indications for ELR are limited to patients with a high probability of recurrent events.(2,4) However, technological advances such as auto-trigger capability and mobile cardiac outpatient telemetry are now showing promising results.”
BackgroundShah, M. J., Silka, M. J., Silva, J. N. A., Balaji, S., Beach, C. M., Benjamin, M. N., Berul, C. I., Cannon, B. C., Cecchin, F., Cohen, M. I., et al. (2021) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2021.07.009 · Cited by 58
Twenty-five years of research on syncope
Fedorowski, A., Kułakowski, P., Brignole, M., de Lange, F. J., Kenny, R. A., Moya‐Mitjans, À., Rivasi, G., Sheldon, R. S., van Dijk, J. G., Sutton, R., et al. (2023) · EP Europace · doi:10.1093/europace/euad163 · Cited by 54
Self-citationRomanov, A. B., Martinek, M., Pürerfellner, H., Chen, S., Melis, M. D., Grazhdankin, I. O., Ponomarev, D., Losik, D., Григорьевич, С. А., Шабанов, В. В., et al. (2016) · EP Europace · doi:10.1093/europace/euw344 · Cited by 50
How to Differentiate Syncope from Seizure
Sheldon, R. S. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.006 · Cited by 51
Brignole, M., Deharo, J., Menozzi, C., Moya‐Mitjans, À., Sutton, R., Tomaino, M., & Ungar, A. (2017) · EP Europace · doi:10.1093/europace/eux321 · Cited by 49
Self-citationDubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
“A strong safety profile, the effectiveness, and a positive impact on resource utilizations in comparison with calendar-based in-office follow-up visits has been consistently and repeatedly demonstrated.(32,34,36,37,41)”
BackgroundSelf-citationDobreanu, D., Svendsen, J. H., Lewalter, T., Hernandez-Madrid, A., Lip, G. Y. H., Blomstrom-Lundqvist, C., & conducted by the Scientific Initiatives Committee, E. H. R. A. (2013) · Europace · doi:10.1093/europace/eut227 · Cited by 45
Self-citationInsertable cardiac monitors: current indications and devices
Sakhi, R., Theuns, D. A. M. J., Szili-Torok, T., & Yap, S.-C. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1557046 · Cited by 39
Bezzerides, V. J., Walsh, A. Z., Martuscello, M., Escudero, C. A., Gauvreau, K., Lam, G., Abrams, D. J., Triedman, J. K., Alexander, M. E., Bevilacqua, L. M., et al. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.09.016 · Cited by 44
“Structural disease 3 (7) 3 (10) Negative EPS 0 (0) 2 (6) Other 5 (11) 1 (3)”
(2020) · PubMed Central · doi:10.6515/acs.202005_36(3).20190903a · Cited by 44
Krahn, A. D., Morillo, C. A., Kus, T., Manns, B., Rose, S., Brignole, M., & Sheldon, R. S. (2012) · Europace · doi:10.1093/europace/eus005 · Cited by 42
“Of note, the European Heart Rhythm Association states that an ILR for syncope and bifascicular block is also a Class IIA indication, indicating the equipoise that supports the conduct of the current study.(19)”
ResultSelf-citationCiconte, G., Saviano, M., Giannelli, L., Ćalović, Ž., Baldi, M., Ciaccio, C., Cuko, A., Vitale, R., Giacopelli, D., Conti, M. A., et al. (2016) · EP Europace · doi:10.1093/europace/euw181 · Cited by 40
Maggi, R., Rafanelli, M., Ceccofiglio, A., Solari, D., Brignole, M., & Ungar, A. (2014) · Europace · doi:10.1093/europace/euu051 · Cited by 37
Self-citationSilva, R. T., Filho, M. M., Peixoto, G. D. L., Lima, J. J. G. D., de Siqueira, S. F., Costa, R., Gowdak, L. H. W., de Paula, F. J., Filho, R. K., & Ramires, J. A. F. (2015) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20150106 · Cited by 40
Implantable loop recorders in the real world: a study of two Canadian centers
Ibrahim, O., Drew, D., Hayes, C. J., McIntyre, W. F., Seifer, C. M., Hopman, W. M., Glover, B. M., & Baranchuk, A. M. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-017-0294-y · Cited by 43
“Current ESC guidelines suggest the use of ILRs in patients with infrequent, severe, and potentially sinister palpitations unexplained by other investigations, when patients are nonadherent to other diagnostic strategies, or when clinically significant arrhythmia must be ruled out [8, 16].”
BackgroundThe Role of Implantable Cardiac Monitors in Atrial Fibrillation Management
Ciconte, G., Giacopelli, D., & Pappone, C. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1590 · Cited by 41
Ahmed, N., Frontera, A., Carpenter, A., CATALDO, S., Connolly, G. M., Fasiolo, M., Cripps, T., Thomas, G., Diab, I. G., & Duncan, E. R. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12666 · Cited by 39
Lacunza-Ruiz, F. J., Moya-Mitjans, A., Martínez-Alday, J., Barón-Esquivias, G., Ruiz-Granell, R., Rivas-Gándara, N., González-Enríquez, S., Leal-del-Ojo, J., F. Arcocha-Torres, M., Pérez-Villacastín, J., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-13-0201 · Cited by 34
Effectiveness and Safety of Remote Monitoring of Patients With an Implantable Loop Recorder
Hernández, Y. D., Toquero‐Ramos, J., Fernández, J. M., Pérez-Pereira, E., Castro‐Urda, V., & Lozano, I. F. (2013) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2013.06.009 · Cited by 36
Sciaraffia, E., Chen, J., Hocini, M., Larsen, T. B., Potpara, T., & Blomstrom-Lundqvist, C. (2014) · Europace · doi:10.1093/europace/euu222 · Cited by 33
Sheldon, R., Talajic, M., Tang, A., Becker, G., Essebag, V., Sultan, O., Baranchuk, A., Ritchie, D., Morillo, C., Krahn, A., et al. (2022) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.10.003 · Cited by 32
Self-citationCurrent and Emerging Indications for Implantable Cardiac Monitors
Giada, F., Bertaglia, E., Reimers, B., Noventa, D., & Raviele, A. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03411.x · Cited by 39
Scrocco, C., Ben‐Haim, Y., Devine, B., Tome, M., Papadakis, M., Sharma, S., Macfarlane, P. W., & Behr, E. R. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.08.034 · Cited by 33
“ILRs may therefore have a 20 role in correlating symptoms and suspected VA in BrS patients (2) ((12)), avoid 21 unnecessary ICD implantation and offer reassurance.”
Implantable loop recorders in the investigation of unexplained syncope: a state of the art review
Parry, S. W., & Matthews, I. G. (2010) · Heart · doi:10.1136/hrt.2010.193417 · Cited by 31
Atrial fibrillation in hypertrophic cardiomyopathy: pathophysiology, diagnosis and management.
Falasconi, G., Pannone, L., Slavich, M., Margonato, A., Fragasso, G., & Spoladore, R. (2020) · PubMed · Cited by 35
An Ultra-Low Power Dual-mode ECG Monitor for Healthcare and Wellness
Bortolotti, D., Mangia, M., Bartolini, A., Rovatti, R., Setti, G., & Benini, L. (2015) · Design, Automation, and Test in Europe · doi:10.7873/date.2015.0784 · Cited by 30
“Holter monitors and loop recorder devices are today used for medical grade ECG recording [7], while reduced leads ECG monitors are used for lifestyle heart rate monitoring, which includes sport activity trackers, obesity and stress detectors.”
BackgroundArrhythmic syncope: From diagnosis to management
Pascual, J. F., Jordán-Marchite, P., Silva, J. R., & Rivas‐Gándara, N. (2023) · World Journal of Cardiology · doi:10.4330/wjc.v15.i4.119 · Cited by 31
Edvardsson, N., Garutti, C., Rieger, G., Linker, N. J., & for the PICTURE Study Investigators (2014) · Clinical Cardiology · doi:10.1002/clc.22300 · Cited by 28
Kanters, T. A., Wolff, C., Boyson, D., Kouakam, C., Dinh, T., Roijen, L. H., & Mölken, M. R. (2015) · EP Europace · doi:10.1093/europace/euv217 · Cited by 29
Paruchuri, V., Adhaduk, M., Garikipati, N. V., Steinberg, J. S., & Mittal, S. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.01.039 · Cited by 29
Shunmugam, S. R., Sugihara, C., Freemantle, N., Round, P., FURNISS, S. S., & Sulke, N. (2018) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-018-0318-2 · Cited by 28
“The gold standard for AF detection is extended beat-to-beat cardiac rhythm monitoring provided by implantable DDDR permanent pacemakers (PPMs) [9].”
BackgroundSelf-citation2020 Clinical practice guidelines for Bradyarrhythmias and conduction disorders
Revishvili, A. S., Artyukhina, Е. А., Глезер, М. Г., Базаев, В. А., Batalov, R. E., Bokeria, L. A., Bokeria, O. L., Davtyan, K. V., Ivanitsky, E. A., Ковалев, А. С., et al. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4448 · Cited by 30
Ambulatory ECG monitoring in the age of smartphones
Sanders, D. J., Ungar, L. D. J., Eskander, M., & Seto, A. H. (2019) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.86a.18123 · Cited by 28
Andersen–Tawil syndrome: deep phenotyping reveals significant cardiac and neuromuscular morbidity
Vivekanandam, V., Männikkö, R., Skorupinska, I., Germain, L., Gray, B. R., Wedderburn, S., Kozyra, D., Sud, R., James, N., Holmes, S. L., et al. (2021) · Brain · doi:10.1093/brain/awab445 · Cited by 27
Recommendations on the utilization of telemedicine in cardiology
Working Group Rhythmology of the Austrian Cardiological Society, Gruska, M., Aigner, G., Altenberger, J., Burkart-Küttner, D., Fiedler, L., Gwechenberger, M., Lercher, P., Martinek, M., Nürnberg, M., et al. (2020) · Wiener klinische Wochenschrift · doi:10.1007/s00508-020-01762-2 · Cited by 29
Can we improve outcomes in AF patients by early therapy?
Kirchhof, P. F. (2009) · BMC Medicine · doi:10.1186/1741-7015-7-72 · Cited by 33
“While conventional Holter electrocardiogram (ECG) recordings have a low diagnostic yield for paroxysmal AF, newer technologies like patient-operated or telemetric ECG systems, long-term Holter monitors, or even implanted ECG monitors carry the promise of allowing an early diagnosis of silent AF [6,35-37].”
BackgroundSelf-citation2025 Clinical practice guidelines for Hypertrophic cardiomyopathy
Bokeria, L. A., Shlyakhto, E. V., Gabrusenko, S. A., Gudkova, A. Y., Koziolova, N. A., Alexandrova, S. A., Alekhin, M. N., Afanasyev, A. V., Bogatyreva, M. M.-B., Bogachev-Prokofiev, A. V., et al. (2025) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2025-6387 · Cited by 30
Syncope in adults: Systematic review and proposal of a diagnostic and therapeutic algorithm
Rosanio, S., Schwarz, E. R., Ware, D. L., & Vitarelli, A. (2011) · International Journal of Cardiology · doi:10.1016/j.ijcard.2011.11.021 · Cited by 28
“Consequently, ELRs are most fruitful in motivated patients with inter-symptom intervals of ≤4 weeks [9].”
BackgroundInfluentialCardiac monitoring for patients with palpitations
Pascual, J. F., Romero, J. C., Pérez‐Rodon, J., Benito, B., Santos‐Ortega, A., Maldonado, J., González, I. F., & Rivas‐Gándara, N. (2021) · World Journal of Cardiology · doi:10.4330/wjc.v13.i11.608 · Cited by 27
Kwok, C. S., Darlington, D., Mayer, J., Panchal, G., Walker, V., Zachariah, D., Phan, T., Mallen, C. D., Barker, D., & Patwala, A. (2022) · Hearts · doi:10.3390/hearts3020007 · Cited by 25
“The established indications for ILR include management of transient loss of consciousness and diagnosis of undocumented palpitations; however, there are fewer established applications, including atrial fibrillation (AF) monitoring and risk stratification, in patients with previous myocardial infarction or inherited ca…”
BackgroundDagres, N., Bongiorni, M. G., Dobreanu, D., Madrid, A., Svendsen, J. H., Blomstrom-Lundqvist, C., & conducted by the Scientific Initiatives Committee, E. H. R. A. (2013) · Europace · doi:10.1093/europace/eut354 · Cited by 24
Vitale, E., Ungar, A., Maggi, R., Francese, M., Lunati, M., Colaceci, R., Rosso, A. D., Castro, A., Santini, M., Giuli, S., et al. (2010) · EP Europace · doi:10.1093/europace/euq302 · Cited by 28
“Based on this study, the recent EHRA position paper ranks asystolic recurrent neurally mediated syncope as Class IIA indication for an ILR.(5) If this recommendation is applied to patients in the present database,(4) of 433 patients with diagnosis of reflex syncope or probably reflex syncope, a further 28 (5%) patient…”
MethodInfluentialSelf-citationDiagnostic accuracy of R‐wave detection by insertable cardiac monitors
Coster, M. D., Demolder, A., Meyer, V. D., Vandenbulcke, F., Heuverswyn, F. V., & Pooter, J. D. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13912 · Cited by 25
Electrophysiology and heart rhythm disorders in older adults.
Goyal, P., & Rich, M. W. (2016) · PubMed Central · doi:10.11909/j.issn.1671-5411.2016.08.001 · Cited by 27
Sutton, R., Ungar, A., Sgobino, P., Russo, V., Massa, R., Melissano, D., Beiras, X., Bottoni, N., Ebert, H., Francese, M., et al. (2014) · EP Europace · doi:10.1093/europace/eut323 · Cited by 26
Self-citation
Metadata
- Authors
- Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, Auricchio, A., Lip, G. Y. H., Almendral, J., Kirchhof, P., Aliot, E., Gasparini, M., Braunschweig, F., Reviewers, D., Lip, G. Y. H., Almendral, J., Kirchhof, P., & Botto, G. L.
- Corresponding author
- Brignole, M.
- ORCID
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-04-28
- Volume
- 11
- Issue
- 5
- Pages
- 671-687
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W1994609836
- Cited by
- 362
- References
- 94
- Citations by year
- 2026: 10 · 2025: 6 · 2024: 12 · 2023: 15 · 2022: 12 · 2021: 29 · 2020: 24 · 2019: 17 · 2018: 25 · 2017: 22 · 2016: 28 · 2015: 27 · 2014: 29 · 2013: 28 · 2012: 14
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- EP Europace (publishedVersion)
- PubMed (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Pure Amsterdam UMC (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- implantable loop recorder, external loop recorder, syncope, auto-activation, risk stratification, Holter monitoring, diagnostic indications, cardiac monitoring devices, event data recorders, battery life
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Humans, Monitoring, Physiologic, Syncope
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.