Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 416

The DOI matches its Crossref record; 460 of the 460 references it cites were found in a registry or an index.

EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: Developed in a partnership with the European Heart Rhythm Association (EHRA), a Registered Branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA)

Open access
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., Kautzner, J., Kay, G. N., Kuck, K.-H., Lerman, B. B., Marchlinski, F., Reddy, V., Schalij, M.-J., Schilling, R., Soejima, K., Wilber, D.·2009·Europace

Abstract

Haemodynamically unstable VT causes haemodynamic compromise requiring prompt termination.Idiopathic VT is a term that has been used to indicate VT that is known to occur in the absence of clinically apparent structural heart disease.Idioventricular rhythm is three or more consecutive beats at a rate of ,100/min that originate from the ventricles independent of atrial or AV nodal conduction.Incessant VT is continuous sustained VT that recurs promptly despite repeated intervention for termination over several hours.Non-clinical VT is a term that has been used to indicate a VT induced by programmed ventricular stimulation that has not been documented previously.This term is problematic because some VTs that have not been previously observed will occur spontaneously.262 It is recommended that this term can be avoided.Induced VTs with a QRS morphology that has not been previously observed should be referred to as 'undocumented VT morphology'.Non-sustained VT terminates spontaneously within 30 s.Presumptive clinical VT is similar to a spontaneous VT based on rate and ECG or electrogram data available from ICD interrogation, but without the 12-lead ECG documentation of either the induced or spontaneous VT.Repetitive monomorphic VT: continuously repeating episodes of self-terminating non-sustained VT. 378,462 Sustained VT: continuous VT for 30 s or that requires an intervention for termination (such as cardioversion).Ventricular tachycardia: a tachycardia (rate .100/min)with three or more consecutive beats that originates from the ventricles independent of atrial or AV nodal conduction.VT storm is considered three or more separate episodes of sustained VT within 24 h, each requiring termination by an intervention.262,463 VT morphologiesMonomorphic VT has a similar QRS configuration from beat to beat (Figure 1A).Some variability in QRS morphology at initiation is not uncommon, followed by stabilization of the QRS morphology.Multiple monomorphic VTs: refers to more than one morphologically distinct monomorphic VT, occurring as different episodes or induced at different times.Polymorphic VT has a continuously changing QRS configuration from beat to beat indicating a changing ventricular activation sequence (Figure 1C).Pleomorphic VT has more than one morphologically distinct QRS complex occurring during the same episode of VT, but the QRS is not continuously changing (Figure 1B).Right and left bundle branch block-like-VT configurations: terms used to describe the dominant deflection in V1, with a dominant R-wave described as 'right bundle branch block-like' and a dominant S-wave as 'left bundle branch block-like' configurations.This terminology is potentially misleading as the VT may not show features characteristic of the same bundle branch block-like morphology in other leads.Unmappable VT does not allow interrogation of multiple sites to define the activation sequence or perform entrainment mapping; this may be due to: haemodynamic intolerance that necessitates immediate VT termination, spontaneous or pacing-induced transition to other morphologies of VT, or repeated termination during mapping.Ventricular flutter is a term that has been applied to rapid VT that has a sinusoidal QRS configuration that prevents identification of the QRS morphology.It is preferable to avoid this term, in favour of monomorphic VT with indeterminant QRS morphology. MechanismsScar-related reentry describes arrhythmias that have characteristics of reentry and originates from an area of myocardial scar identified from electrogram characteristics or myocardial imaging.Large reentry circuits that can be defined over several centimetres are commonly referred to as 'macroreentry'.Focal VT has a point source of earliest ventricular activation with a spread of activation away in all directions from that site.The mechanism can be automaticity, triggered activity, or microreentry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eup098

Cites

460 of 460 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 460 references

Cited by

See all 416

Metadata

Authors
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., Kautzner, J., Kay, G. N., Kuck, K.-H., Lerman, B. B., Marchlinski, F., Reddy, V., Schalij, M.-J., Schilling, R., Soejima, K., & Wilber, D.
Venue
Europace
Published
2009-05-14
Volume
11
Issue
6
Pages
771-817
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W3030153550
Cited by
416
References
460
FWCI
16.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: Developed in a partnership with the European Heart Rhythm Association (EHRA), a Registered Branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA). https://app.cochat.ai/papers/10.1093/europace/eup098
The paper
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., Kautzner, J., Kay, G. N., Kuck, K.-H., Lerman, B. B., Marchlinski, F., Reddy, V., Schalij, M.-J., Schilling, R., Soejima, K., & Wilber, D. (2009). EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: Developed in a partnership with the European Heart Rhythm Association (EHRA), a Registered Branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA). Europace. https://doi.org/10.1093/europace/eup098

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.