Cited by 57Cardiovascular Syncope and Autonomic DisordersCardiac pacing and defibrillation studiesECG Monitoring and Analysis

Effectiveness of remote monitoring in the management of syncope and palpitations

Open access
Furukawa, T., Maggi, R., Bertolone, C., Ammirati, F., Santini, M., Ricci, R., Giada, F., Brignole, M.·2011·Europace

Abstract

AIMS: Recently, the remote transmission of data detected by implantable loop recorders (ILRs) has become available. The aim of this study was to evaluate effectiveness and acceptance of remote monitoring in the clinical management of syncope and palpitations in patients with ILR. METHODS AND RESULTS: Consecutive patients implanted with ILR (Reveal DX/XT Medtronic, Inc.) and followed up by means of remote monitoring (CareLink(®)) were included. The patients were requested to transmit the data stored in the ILR every week, via the CareLink system, or more frequently during the first period. Patient acceptance of ILR was evaluated by means of a questionnaire concerning physical and mental components. Forty-seven patients (27 males, average age 64 ± 19 years) were enrolled and followed up for 20 ± 13 weeks. Thirty-two patients (68%) had at least one ECG recording of a true relevant event. The mean time from ILR implantation to the first true relevant ECG was 28 ± 49 days, which was 71 ± 17 days less than in the clinical practice of 3-monthly in-office follow-up examinations. Thirty-eight patients (81%) had at least one false arrhythmic event, mainly false asystole and false fast ventricular tachycardia. In the absence of Carelink transmission, at least one episode of memory saturation of ILR would have occurred in 21 patients (45%) that would have limited the diagnostic yield. Patient compliance was good even though one-fifth had some minor psychological concern regarding the ILR implant. CareLink was well accepted and judged easy to use. CONCLUSION: Remote monitoring enhances the diagnostic effectiveness of Reveal, limiting the risk of memory saturation due to the high number of false detections and reducing the time to diagnosis. Both ILR and CareLink were well accepted and well tolerated by the patients, as they were considered useful.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euq503

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Some recent studies have shown that implementing remote monitoring increases the diagnostic yield and achieves diagnosis earlier than without remote monitoring.

    “Some recent studies have shown that implementing remote monitoring increases the diagnostic yield and achieves diagnosis earlier than without remote monitoring. 169-171”

    From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [170]

    The Discussion reports that relevant ECGs were detected in 28 days, an estimated 71 days earlier than with the departments’ three-monthly in-office follow-up. It says remote monitoring *potentially* increases the diagnostic yield of implantable loop recorders by reducing memory saturation; the claim states that increase as an established result. Page numbers are unavailable in our copy. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Furukawa, T., Maggi, R., Bertolone, C., Ammirati, F., Santini, M., Ricci, R., Giada, F., & Brignole, M.
Affiliations
  • Presidio Ospedaliero (IT)
  • Ospedale San Filippo Neri (IT)
  • Ospedale dell' Angelo (IT)
Corresponding author
Brignole, M.
Venue
Europace
Published
2011-01-17
Volume
13
Issue
3
Pages
431-437
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2133404031
Cited by
57
References
22
Citations by year
2026: 4 · 2024: 1 · 2023: 3 · 2022: 3 · 2019: 2 · 2018: 9 · 2017: 4 · 2016: 3 · 2015: 5 · 2014: 4 · 2013: 13 · 2012: 4
FWCI
7.54
Type
journal article
Language
en
Open access
Locations
  • EP Europace (publishedVersion)
  • PubMed (publishedVersion)
  • INFM-OAR (INFN Catania) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
remote monitoring, implantable loop recorder, syncope, palpitations, memory saturation, patient acceptance, diagnostic yield, arrhythmia detection
MeSH terms
Adult, Aged, Aged, 80 and over, Arrhythmias, Cardiac, Electrocardiography, Female, Follow-Up Studies, Humans, Male, Middle Aged, Monitoring, Physiologic, Patient Compliance, Prospective Studies, Retrospective Studies, Syncope, Electrocardiography, Ambulatory, Prostheses and Implants, Remote Sensing Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review