Association between left atrial size and atrial fibrillation recurrence after single circumferential pulmonary vein isolation: a systematic review and meta-analysis of observational studies
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
AIMS: Left atrial (LA) enlargement is associated with atrial fibrillation (AF). However, it is controversial whether dilated atrium can predict post-ablation AF recurrence. We undertook a systematic review and meta-analysis to analyse the association between LA diameter and AF recurrence after single circumferential pulmonary vein isolation (CPVI) and explore the potential mechanism. METHODS AND RESULTS: Electronic databases and bibliographies of retrieved studies were searched. The anteroposterior diameters of LA were available in all included studies, which were measured at end-systole by M-mode transthoracic echocardiography. Subgroup analysis was conducted based on the duration of follow-up. Weighted mean difference (WMD) and 95% confidence interval (CI) were calculated using random-effect or fixed-effect model, depending on statistical heterogeneity. Twenty-two studies with a total of 3750 individuals met the inclusion criteria. The summary WMD of LA diameter between patients with and without recurrence was 1.87 mm (95% CI 1.26-2.48, P< 0.001). Meta-regression analysis of the 22 studies indicated that study design, duration of follow-up, and measurement of asymptomatic recurrences were significant sources of heterogeneity. Sensitivity analysis suggested that the difference in LA diameter between patients with and without recurrences persisted regardless of the duration of follow-up. CONCLUSION: Dilated LA significantly increases the risk of AF recurrence after single CPVI. This is especially applicable to the patients with long-term follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“Statistical heterogeneity was evaluated with x(2) test and quantified by I(2) statistic, which assessed the appropriateness of pooling the individual study results.(9) A value of P , 0.”
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763 · cited 1×
“56% indicated significant between-study heterogeneity.(10) If no heterogeneity was present, fixed-effect estimates of WMD were calculated according to the inverse variance method.”
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 1×
“strategies, circumferential pulmonary vein isolation (CPVI) is more popular in electrophysiology centres.(4) Despite advances in the ablation technique, AF recurrences are common and significant number of patients require repeated procedures.”
Wann, L. S., Curtis, A. B., January, C. T., Ellenbogen, K. A., Lowe, J. E., Estes, N. A. M., Page, R. L., Ezekowitz, M. D., Slotwiner, D. J., Jackman, W. M., et al. (2011) · Circulation · doi:10.1161/cir.0b013e3181fa3cf4 · Cited by 1,336
Atrial Fibrosis: Mechanisms and Clinical Relevance in Atrial Fibrillation
Burstein, B., & Nattel, S. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.064 · Cited by 1,242 · cited 1×
“fest as a reduction in myocardium and an increase in atrial fibrosis.(36) Atrial fibrosis is a hallmark of atrial structural remodelling and leads to trigger and persistence of AF through changes in substrate of LA and subsequent electrical remodelling.”
Oakes, R. S., Badger, T. J., Kholmovski, E. G., Akoum, N., Burgon, N. S., Fish, E. N., Blauer, J. J. E., Rao, S. N., DiBella, E. V. R., Segerson, N. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.811877 · Cited by 1,123 · cited 3×
“sion of studies treated with other ablation strategies, the CPVI remains a varying ablation method, ranging from stepwise approach(1) to very extensive substrate ablation.(7,38) In this meta-analysis, we are unable to distinguish whether diverse additional ablation lines have influence on the association”
Pappone, C., Santinelli, V., Manguso, F., Vicedomini, G., Gugliotta, F., Augello, G., Mazzone, P., Tortoriello, V., Landoni, G., Zangrillo, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112641.16340.c7 · Cited by 1,018 · cited 2×
“CPVI plus ECG, 24 h Holter 0 9+7 CAD Pappone et al.(18) CPVI plus ECG, 24 h or 48 h Holter 1 week 12 CVD Kuppahally et al.”
InfluentialCircumferential Pulmonary-Vein Ablation for Chronic Atrial Fibrillation
Oral, H., Pappone, C., Chugh, A., Good, E., Bogun, F., Pelosi, F., Bates, E. R., Lehmann, M. H., Vicedomini, G., Augello, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa050955 · Cited by 976 · cited 2×
“than drug therapy in restoring sinus rhythm in patients with atrial fibrillation (AF).(1,2) ACCF/AHA/HRS practice guidelines in 2011 recommend catheter ablation as class I recommendation supported with level A evidence.”
Catheter Ablation Versus Antiarrhythmic Drugs for Atrial Fibrillation: The A4 Study
Jaïs, P., Cauchemez, B., Macle, L., Daoud, E., Khairy, P., Subbiah, R., Hocini, M., Extramiana, F., Sacher, F., Bordachar, P., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.772582 · Cited by 891 · cited 2×
“than drug therapy in restoring sinus rhythm in patients with atrial fibrillation (AF).(1,2) ACCF/AHA/HRS practice guidelines in 2011 recommend catheter ablation as class I recommendation supported with level A evidence.”
Cited by
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Njoku, A., Kannabhiran, M., Arora, R., Reddy, P., Gopinathannair, R., Lakkireddy, D., & Dominic, P. (2018) · EP Europace · doi:10.1093/europace/eux013 · Cited by 419
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Metadata
- Authors
- Zhuang, J., Wang, Y., Tang, K., Li, X., Peng, W., Liang, C., & Xu, Y.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-11-23
- Volume
- 14
- Issue
- 5
- Pages
- 638-645
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2117629410
- Cited by
- 207
- References
- 44
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.