Association between left atrial size and atrial fibrillation recurrence after single circumferential pulmonary vein isolation: a systematic review and meta-analysis of observational studies
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
AIMS: Left atrial (LA) enlargement is associated with atrial fibrillation (AF). However, it is controversial whether dilated atrium can predict post-ablation AF recurrence. We undertook a systematic review and meta-analysis to analyse the association between LA diameter and AF recurrence after single circumferential pulmonary vein isolation (CPVI) and explore the potential mechanism. METHODS AND RESULTS: Electronic databases and bibliographies of retrieved studies were searched. The anteroposterior diameters of LA were available in all included studies, which were measured at end-systole by M-mode transthoracic echocardiography. Subgroup analysis was conducted based on the duration of follow-up. Weighted mean difference (WMD) and 95% confidence interval (CI) were calculated using random-effect or fixed-effect model, depending on statistical heterogeneity. Twenty-two studies with a total of 3750 individuals met the inclusion criteria. The summary WMD of LA diameter between patients with and without recurrence was 1.87 mm (95% CI 1.26-2.48, P< 0.001). Meta-regression analysis of the 22 studies indicated that study design, duration of follow-up, and measurement of asymptomatic recurrences were significant sources of heterogeneity. Sensitivity analysis suggested that the difference in LA diameter between patients with and without recurrences persisted regardless of the duration of follow-up. CONCLUSION: Dilated LA significantly increases the risk of AF recurrence after single CPVI. This is especially applicable to the patients with long-term follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“Statistical heterogeneity was evaluated with x(2) test and quantified by I(2) statistic, which assessed the appropriateness of pooling the individual study results.(9) A value of P , 0.”
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763 · cited 1×
“56% indicated significant between-study heterogeneity.(10) If no heterogeneity was present, fixed-effect estimates of WMD were calculated according to the inverse variance method.”
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 1×
“strategies, circumferential pulmonary vein isolation (CPVI) is more popular in electrophysiology centres.(4) Despite advances in the ablation technique, AF recurrences are common and significant number of patients require repeated procedures.”
Wann, L. S., Curtis, A. B., January, C. T., Ellenbogen, K. A., Lowe, J. E., Estes, N. A. M., Page, R. L., Ezekowitz, M. D., Slotwiner, D. J., Jackman, W. M., et al. (2011) · Circulation · doi:10.1161/cir.0b013e3181fa3cf4 · Cited by 1,336
Atrial Fibrosis: Mechanisms and Clinical Relevance in Atrial Fibrillation
Burstein, B., & Nattel, S. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.064 · Cited by 1,242 · cited 1×
“fest as a reduction in myocardium and an increase in atrial fibrosis.(36) Atrial fibrosis is a hallmark of atrial structural remodelling and leads to trigger and persistence of AF through changes in substrate of LA and subsequent electrical remodelling.”
Oakes, R. S., Badger, T. J., Kholmovski, E. G., Akoum, N., Burgon, N. S., Fish, E. N., Blauer, J. J. E., Rao, S. N., DiBella, E. V. R., Segerson, N. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.811877 · Cited by 1,123 · cited 3×
“sion of studies treated with other ablation strategies, the CPVI remains a varying ablation method, ranging from stepwise approach(1) to very extensive substrate ablation.(7,38) In this meta-analysis, we are unable to distinguish whether diverse additional ablation lines have influence on the association”
Pappone, C., Santinelli, V., Manguso, F., Vicedomini, G., Gugliotta, F., Augello, G., Mazzone, P., Tortoriello, V., Landoni, G., Zangrillo, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112641.16340.c7 · Cited by 1,018 · cited 2×
“CPVI plus ECG, 24 h Holter 0 9+7 CAD Pappone et al.(18) CPVI plus ECG, 24 h or 48 h Holter 1 week 12 CVD Kuppahally et al.”
InfluentialCircumferential Pulmonary-Vein Ablation for Chronic Atrial Fibrillation
Oral, H., Pappone, C., Chugh, A., Good, E., Bogun, F., Pelosi, F., Bates, E. R., Lehmann, M. H., Vicedomini, G., Augello, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa050955 · Cited by 976 · cited 2×
“than drug therapy in restoring sinus rhythm in patients with atrial fibrillation (AF).(1,2) ACCF/AHA/HRS practice guidelines in 2011 recommend catheter ablation as class I recommendation supported with level A evidence.”
Catheter Ablation Versus Antiarrhythmic Drugs for Atrial Fibrillation: The A4 Study
Jaïs, P., Cauchemez, B., Macle, L., Daoud, E., Khairy, P., Subbiah, R., Hocini, M., Extramiana, F., Sacher, F., Bordachar, P., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.772582 · Cited by 891 · cited 2×
“than drug therapy in restoring sinus rhythm in patients with atrial fibrillation (AF).(1,2) ACCF/AHA/HRS practice guidelines in 2011 recommend catheter ablation as class I recommendation supported with level A evidence.”
Pre-existent left atrial scarring in patients undergoing pulmonary vein antrum isolation
Verma, A., Wazni, O. M., Marrouche, N. F., Martin, D. O., Kilicaslan, F., Minor, S., Schweikert, R. A., Saliba, W., Cummings, J., Burkhardt, J. D., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.035 · Cited by 595 · cited 4×
“3 Complication Verma et al.(7) CPVI plus ECG, transtelephonic ECG, implanted devices, 48 h Holter 2 15.”
InfluentialWann, L. S., Curtis, A. B., Ellenbogen, K. A., Estes, N. A. M., Ezekowitz, M. D., Jackman, W. M., January, C. T., Lowe, J. E., Page, R. L., Slotwiner, D. J., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31820f14c0 · Cited by 399
Wann, L. S., Curtis, A. B., Ellenbogen, K. A., Estes, N. A. M., Ezekowitz, M. D., Jackman, W. M., January, C. T., Lowe, J. E., Page, R. L., Slotwiner, D. J., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.01.032 · Cited by 395 · cited 1×
“ACCF/AHA/HRS practice guidelines in 2011 recommend catheter ablation as class I recommendation supported with level A evidence.(3) Compared with other ablation”
Yue, L., Xie, J., & Nattel, S. (2011) · Cardiovascular Research · doi:10.1093/cvr/cvq329 · Cited by 366 · cited 1×
“Atrial fibrosis is a hallmark of atrial structural remodelling and leads to trigger and persistence of AF through changes in substrate of LA and subsequent electrical remodelling.(37) Second, it is conceivable that patients with larger LA require more energy and longer lesions to complete the ablation.”
Verma, A., Mantovan, R., Macle, L., De Martino, G., Chen, J., Morillo, C. A., Novak, P., Calzolari, V., Guerra, P. G., Nair, G., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq041 · Cited by 315 · cited 1×
“Of note, four of the excluded studies were of randomized controlled design, but re-ablations were conducted in these studies.(1,2,11,12) Of the remaining 24 studies, 6 provided further data upon request.”
Kirchhof, P., Auricchio, A., Bax, J., Crijns, H., Camm, J., Diener, H.-C., Goette, A., Hindricks, G., Hohnloser, S., Kappenberger, L., et al. (2007) · Europace · doi:10.1093/europace/eum191 · Cited by 293 · cited 1×
“Apart from conventional 12-lead electrocardiography (ECG), appropriate approaches to the detection of asymptomatic recurrent AF should include Holter, transtelephonic monitoring, and implanted device alone or in combination during follow-up.(8) Data from eligible studies were extracted independently by two reviewers w…”
New antiarrhythmic drugs for treatment of atrial fibrillation
Dobrev, D., & Nattel, S. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60096-7 · Cited by 284
BALK, E. M., GARLITSKI, A. C., ALSHEIKH‐ALI, A. A., TERASAWA, T., CHUNG, M., & IP, S. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01798.x · Cited by 257 · cited 5×
“Paroxysmal AF was self-terminating in ,7 days, usually within 48 h, as opposed to non-paroxysmal AF including persistent and permanent/long-standing persistent AF lasting beyond 7 days, or necessitating pharmacological or electrical cardioversion, which was defined as recurrent AF.”
InfluentialLeft Atrial Strain Predicts Reverse Remodeling After Catheter Ablation for Atrial Fibrillation
Tops, L. F., Delgado, V., Bertini, M., Marsan, N. A., Den Uijl, D. W., Trines, S. A. I. P., Zeppenfeld, K., Holman, E., Schalij, M. J., & Bax, J. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.05.063 · Cited by 223 · cited 1×
“reversal of LA remodelling after ablation, whereas a more advanced remodelling of the LA may not be ameliorated.(19,35)”
From Selective Parasympathetic Modulation of AV Node to Rate Control Therapy
BILLETTE, J., & LAVALLÉE, M. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.00271.x · Cited by 222
Chromosome 4q25 Variants and Atrial Fibrillation Recurrence After Catheter Ablation
Husser, D., Adams, V., Piorkowski, C., Hindricks, G., & Bollmann, A. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.041 · Cited by 218 · cited 3×
“CPVI plus ECG, 24 h Holter 12 weeks 6 LA volume max Husser et al.(15) CPVI plus ECG, 7-day Holter 3 6 Chr 4q25 variants Shin et al.”
InfluentialGaita, F., Caponi, D., Scaglione, M., Montefusco, A., Corleto, A., Di Monte, F., Coin, D., Di Donna, P., & Giustetto, C. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.774885 · Cited by 212 · cited 1×
“Of note, four of the excluded studies were of randomized controlled design, but re-ablations were conducted in these studies.(1,2,11,12) Of the remaining 24 studies, 6 provided further data upon request.”
Wann, L. S., Curtis, A. B., Ellenbogen, K. A., Estes, N. A. M., Ezekowitz, M. D., Jackman, W. M., January, C. T., Lowe, J. E., Page, R. L., Slotwiner, D. J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.010 · Cited by 175
Olshansky, B., Heller, E. N., Mitchell, L. B., Chandler, M. L., Slater, W., Green, M. S., Brodsky, M. A., Barrell, P., & Greene, H. L. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.020 · Cited by 169
Kuppahally, S. S., AKOUM, N. W., Badger, T. J., Burgon, N. S., Haslam, T. S., Kholmovski, E. G., MacLeod, R., McGann, C. J., & MARROUCHE, N. F. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.07.003 · Cited by 145 · cited 3×
“CPVI plus ECG, 24 h or 48 h Holter 1 week 12 CVD Kuppahally et al.(19) CPVI plus ECG, 24 h Holter, event monitor 8 weeks 12 LA wall fibrosis Yamada et al.”
Influentialden Uijl, D. W., Delgado, V., Bertini, M., Tops, L. F., Trines, S. A. I. P., de Veire, N. R. V., Zeppenfeld, K., Schalij, M. J., & Bax, J. J. (2011) · Heart · doi:10.1136/hrt.2010.215335 · Cited by 132 · cited 2×
“LA enlargement show a varying response to catheter ablation while patients with a severely enlarged LA may be accurately identified as ‘high risk’ for relapse.(41) Additionally, when LA dilation inclines to asymmetry, LA volume prioritizes to LA diameter.”
Letsas, K. P., Weber, R., Burkle, G., Mihas, C. C., Minners, J., Kalusche, D., & Arentz, T. (2008) · Europace · doi:10.1093/europace/eun309 · Cited by 132 · cited 3×
“Verma et al. (2004)13 USA Retro 102 56+11 86.3 0 45.5 68 (66.7) Delgado et al. (2008)14 Spain Retro 34 53+13 70.6 67.6 41+7 21 (61.8) Husser et al. (2010)15 Germany Prosp 195 56+12 73.3 78.8 43+7 155 (79.5) Shin et al. (2011)33 Republic of Korea Prosp 80 53.4+10.4 57.5 76.3 41.5+4.0 58 (72.5) Nakazawa et al. (2009)16…”
InfluentialEffect of Radiofrequency Catheter Ablation for Atrial Fibrillation on Left Atrial Cavity Size
Tops, L. F., Bax, J. J., Zeppenfeld, K., Jongbloed, M. R. M., van der Wall, E. E., & Schalij, M. J. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.043 · Cited by 109 · cited 1×
“Additionally, when LA dilation inclines to asymmetry, LA volume prioritizes to LA diameter.(14,42) On the other hand, although transthoracic echocardiography is”
MIYAZAKI, S., KUWAHARA, T., KOBORI, A., TAKAHASHI, Y., TAKEI, A., SATO, A., ISOBE, M., & TAKAHASHI, A. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01984.x · Cited by 81 · cited 4×
“Miyazaki et al.(32) CPVI plus ECG, Holter 1 29.”
InfluentialChekakie, M. O. A., Akar, J. G., Wang, F., Muradi, H. A., WU, J. M., Santucci, P. A., Varma, N., & Wilber, D. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00887.x · Cited by 78 · cited 3×
“…al. (2007)23 Italy Retro 28 59.0+8.8 67.8 100 45.0+5.5 15 (53.6) Letsas et al. (2009)24 Germany Prospa 72 54.9+8.8 80.6 63.9 40.6+5.6 44 (61.1) Al Chekakie et al. (2007)25 USA Retro 177 56+11 71.2 74.6 45.2 132 (74.5) Tang et al. (2006)26 China Prosp 263 56.7 71.5 75.7 38.6 201 (76.4) Verma et…”
InfluentialTang, R., Dong, J., Liu, X.-P., Kang, J. P., Ding, S.-F., Wang, L., Long, D., Yu, R., Liu, X., Liu, S., et al. (2008) · EP Europace · doi:10.1093/europace/eun315 · Cited by 77 · cited 3×
“CPVI ECG, 24 h Holter 1 12 0 Tang et al.(22) CPVI plus ECG, 24 h Holter, event monitor 3 11.”
InfluentialDe Potter, T., Berruezo, A., Mont, L., Matiello, M., Tamborero, D., Santibanez, C., Benito, B., Zamorano, N., & Brugada, J. (2010) · Europace · doi:10.1093/europace/eup309 · Cited by 71 · cited 3×
“Verma et al. (2004)13 USA Retro 102 56+11 86.3 0 45.5 68 (66.7) Delgado et al. (2008)14 Spain Retro 34 53+13 70.6 67.6 41+7 21 (61.8) Husser et al. (2010)15 Germany Prosp 195 56+12 73.3 78.8 43+7 155 (79.5) Shin et al. (2011)33 Republic of Korea Prosp 80 53.4+10.4 57.5 76.3 41.5+4.0 58 (72.5) Nakazawa et al. (2009)16…”
InfluentialChao, T.-F., Sung, S., Wang, K.-L., Lin, Y.-J., Chang, S., Lo, L.-W., Hu, Y., TUAN, T., Suenari, K., Li, C., et al. (2010) · Heart · doi:10.1136/hrt.2010.212373 · Cited by 69 · cited 2×
“3 ERAF Chao et al.(30) CPVI plus ECG, 24 h Holter, event monitor 1 23+13 PA-PDI interval Patel et al.”
InfluentialDelgado, V., Vidal, B., Sitges, M., Tamborero, D., Mont, L., Berruezo, A., Azqueta, M., Paré, C., & Brugada, J. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.12.028 · Cited by 63 · cited 4×
“Verma et al. (2004)13 USA Retro 102 56+11 86.3 0 45.5 68 (66.7) Delgado et al. (2008)14 Spain Retro 34 53+13 70.6 67.6 41+7 21 (61.8) Husser et al. (2010)15 Germany Prosp 195 56+12 73.3 78.8 43+7 155 (79.5) Shin et al. (2011)33 Republic of Korea Prosp 80 53.4+10.4 57.5 76.3 41.5+4.0 58 (72.5)…”
InfluentialShin, S. Y., Na, J. O., Lim, H. E., CHOI, C. U., Choi, J., Kim, S. H., Kim, E. J., PARK, S. W., Rha, S., Park, C. G., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01919.x · Cited by 63 · cited 2×
“CPVI plus ECG, 7-day Holter 3 6 Chr 4q25 variants Shin et al.(33) CPVI plus ECG, 48 h Holter 0 6 LA volume, FMD, highly sensitive CRP Nakazawa et al.”
InfluentialEfremidis, M., Sideris, A., Xydonas, S., Letsas, Κ. P., Alexanian, I. P., Manolatos, D., Mihas, C. C., Filippatos, G. S., & Kardaras, F. G. (2008) · PubMed · Cited by 52
Patel, D., Mohanty, P. K., Biase, L. D., Wang, Y., Shaheen, M., Sanchez, J. E., Horton, R., Gallinghouse, G., ZAGRODZKY, J. D., Bailey, S., et al. (2010) · EP Europace · doi:10.1093/europace/eup387 · Cited by 47 · cited 4×
“CPVI plus ECG, 24 h Holter, event monitor 1 23+13 PA-PDI interval Patel et al.(31) CPVI plus 48 h Holter, event monitor, transtelephonic ECG 8 weeks 24+8.”
InfluentialSelf-citationPing, X., Dong, J., Liu, X. P., Long, D., Yu, R. H., Tian, Y., Tang, R. B., Zheng, B., Hu, F. L., Shi, L., et al. (2008) · Circulation Journal · doi:10.1253/circj.72.1125 · Cited by 46
Tang, R. B., Dong, J., Liu, X. P., Fang, D. P., Long, D., Liu, X., Yu, R. H., Hu, F. L., Lu, C. S., Hao, P., et al. (2007) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-9049-x · Cited by 38 · cited 3×
“…et al. (2009)24 Germany Prospa 72 54.9+8.8 80.6 63.9 40.6+5.6 44 (61.1) Al Chekakie et al. (2007)25 USA Retro 177 56+11 71.2 74.6 45.2 132 (74.5) Tang et al. (2006)26 China Prosp 263 56.7 71.5 75.7 38.6 201 (76.4) Verma et al. (2005)7 USA Retro 700 54 77.9 39.1 41.7 548 (78.3) De Potter et al.…”
InfluentialVerma, A., Marrouche, N. F., Yamada, H., Grimm, R. A., Cummings, J. E., Burkhardt, J. D., Kılıçaslan, F., Bhargava, M., Karim, A.-A., Thomas, J. D., et al. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.06.039 · Cited by 33 · cited 3×
“Verma et al. (2004)13 USA Retro 102 56+11 86.3 0 45.5 68 (66.7) Delgado et al. (2008)14 Spain Retro 34 53+13 70.6 67.6 41+7 21 (61.8) Husser et al. (2010)15 Germany Prosp 195 56+12 73.3 78.8 43+7 155 (79.5) Shin et al. (2011)33 Republic of Korea Prosp 80 53.4+10.4 57.5 76.3 41.5+4.0 58 (72.5)…”
InfluentialBertaglia, E., Stabile, G., SENATORE, G., Turco, P., Donnici, G., Simone, A. D., FAZZARI, M., Zerbo, F., & Pascotto, P. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00309.x · Cited by 22 · cited 1×
“…(78.3) De Potter et al. (2010)27 Spain Retro 72 51.5 91.9 40.3 42.7 38 (52.8) Kurotobi et al. (2010)28 Japan Prosp 257 61 72.8 70.0 ,55 212 (82.5) Bertaglia et al. (2006)29 Italy Retro 74 61.5+7.0 75.7 0 48.9+5.3 52 (70.3) Chao et al. (2010)30 Taiwan, China Retro 132 50.7+10.4 69.7 100 37.4+5.2…”
InfluentialYamada, T., Yoshida, N., Murakami, Y., Okada, T., Yoshida, Y., Muto, M., Inden, Y., & Murohara, T. (2009) · EP Europace · doi:10.1093/europace/eup330 · Cited by 20 · cited 3×
“CPVI plus ECG, 24 h Holter, event monitor 8 weeks 12 LA wall fibrosis Yamada et al.(20) CPVI plus 24 h Holter, event monitor 0 12 0 Liu et al.”
InfluentialKurotobi, T., Iwakura, K., Inoue, K., Kimura, R., Okamura, A., Koyama, Y., Toyoshima, Y., Ito, N., & Fujii, K. (2010) · EP Europace · doi:10.1093/europace/euq155 · Cited by 17 · cited 4×
“CPVI plus ECG, Holter 3 16+13 LA diameter Kurotobi et al.(28) CPVI plus ECG, 24 h Holter 2 19.”
InfluentialLiu, Z., Ling, Z., Su, L., Wu, J., Lan, X., Chen, Y., Du, H., She, Q., & Yin, Y. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9301-7 · Cited by 13 · cited 3×
“CPVI plus 24 h Holter, event monitor 0 12 0 Liu et al.(21) CPVI ECG, 24 h Holter 1 12 0 Tang et al.”
Influential
Cited by
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Njoku, A., Kannabhiran, M., Arora, R., Reddy, P., Gopinathannair, R., Lakkireddy, D., & Dominic, P. (2018) · EP Europace · doi:10.1093/europace/eux013 · Cited by 419
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Metadata
- Authors
- Zhuang, J., Wang, Y., Tang, K., Li, X., Peng, W., Liang, C., & Xu, Y.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-11-23
- Volume
- 14
- Issue
- 5
- Pages
- 638-645
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2117629410
- Cited by
- 207
- References
- 44
- FWCI
- 1.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.