Cited by 94Cardiac pacing and defibrillation studiesCardiac Arrest and ResuscitationCardiac Structural Anomalies and Repair

First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system: novel endocardial left ventricular resynchronization therapy in heart failure patients

Auricchio, A., Delnoy, P.-P., Regoli, F., Seifert, M., Markou, T., Butter, C., for the collaborative study group·2013·Europace

Abstract

AIMS: The importance of specific-site pacing is increasingly recognized in cardiac resynchronization therapy (CRT). Using current pacing technology, site selection is still largely limited by coronary vein anatomy, whereas left ventricular (LV) endocardial pacing using current lead technology is risky and challenging. To overcome limitations and complications with current LV pacing, the feasibility of a new technology enabling LV endocardial stimulation without the use of a lead is being evaluated in patients. METHODS AND RESULTS: Patients presented in this report are part of the Wireless Stimulation Endocardially for CRT Trial (WiSE-CRT) study investigating the safety and performance of the WiCS(®)-LV system, an implantable cardiac pacing system capable of leadless pacing based on converting ultrasound energy to electrical energy. Three patients are presented: (i) a patient with an existing implantable defibrillator, (ii) a patient with a CRT system whose LV lead does not capture, and (iii) a CRT patient classified as a non-responder. All three patients were successfully treated. Acute electrical pacing thresholds ranged from 0.7 to 1.0 V at 0.5 ms; all patients retained captured at 6 months. Functional New York Heart Association class significantly changed (Pre: III in two patients, and IV in one patient; Post: I in one patient, II in one patient, and II-III in one patient), and LV ejection fraction increased from 23.7 ± 3.4% to 39 ± 6.2% (P < 0.017). CONCLUSION: This report on three first-in-man cases shows that leadless endocardial pacing may be safely applied and effective, conferring short- to-mid-term symptomatic benefits. These promising findings are yet to be substantiated by larger ongoing studies. CLINICAL TRIAL REGISTRATION INFORMATION: http://clinicaltrials.gov/ct2/show/NCT01294527.

Integrity signals

Registry

Crossref · 10.1093/europace/eut124

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Alternative leadless solutions such as energy harvesters and ultrasound-based wireless pacers are hindered by a large device size that leads to mechanically stressed fixation mechanisms.

    “Alternative solutions for leadless devices have been proposed, including utilization of energy harvesters11, 12 and ultrasound-based wireless pacers8, 13, 14. However, these are similarly hindered by a large device size that leads to mechanically stressed fixation mechanisms.”

Cited by

Sorted by citations

Authors
Auricchio, A., Delnoy, P.-P., Regoli, F., Seifert, M., Markou, T., Butter, C., & for the collaborative study group
Affiliations
  • Istituto Cardiocentro Ticino (CH)
  • Isala (NL)
  • Immanuel Klinikum Bernau (DE)
Corresponding author
Auricchio, A.
Venue
Europace
Published
2013-05-23
Volume
15
Issue
8
Pages
1191-1197
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2152403933
Cited by
94
References
0
Citations by year
2025: 3 · 2024: 4 · 2023: 3 · 2022: 7 · 2021: 8 · 2020: 10 · 2019: 3 · 2018: 10 · 2017: 6 · 2016: 10 · 2015: 14 · 2014: 14 · 2013: 2
FWCI
9.07
Type
journal article
Language
en
Open access
closed
Locations
  • EP Europace (publishedVersion)
  • PubMed (publishedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (acceptedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
  • Health Sciences › Medicine › Surgery › Cardiac Structural Anomalies and Repair
Keywords
left ventricular endocardial pacing, cardiac resynchronization therapy, heart failure, pacing threshold, implantable cardioverter-defibrillator
MeSH terms
Aged, Cardiac Pacing, Artificial, Electrodes, Implanted, Equipment Design, Heart Failure, Humans, Male, Pacemaker, Artificial, Pilot Projects, Ultrasonic Therapy, Treatment Outcome, Ventricular Dysfunction, Left, Equipment Failure Analysis, Prostheses and Implants, Micro-Electrical-Mechanical Systems, Wireless Technology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review