First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system: novel endocardial left ventricular resynchronization therapy in heart failure patients
Abstract
AIMS: The importance of specific-site pacing is increasingly recognized in cardiac resynchronization therapy (CRT). Using current pacing technology, site selection is still largely limited by coronary vein anatomy, whereas left ventricular (LV) endocardial pacing using current lead technology is risky and challenging. To overcome limitations and complications with current LV pacing, the feasibility of a new technology enabling LV endocardial stimulation without the use of a lead is being evaluated in patients. METHODS AND RESULTS: Patients presented in this report are part of the Wireless Stimulation Endocardially for CRT Trial (WiSE-CRT) study investigating the safety and performance of the WiCS(®)-LV system, an implantable cardiac pacing system capable of leadless pacing based on converting ultrasound energy to electrical energy. Three patients are presented: (i) a patient with an existing implantable defibrillator, (ii) a patient with a CRT system whose LV lead does not capture, and (iii) a CRT patient classified as a non-responder. All three patients were successfully treated. Acute electrical pacing thresholds ranged from 0.7 to 1.0 V at 0.5 ms; all patients retained captured at 6 months. Functional New York Heart Association class significantly changed (Pre: III in two patients, and IV in one patient; Post: I in one patient, II in one patient, and II-III in one patient), and LV ejection fraction increased from 23.7 ± 3.4% to 39 ± 6.2% (P < 0.017). CONCLUSION: This report on three first-in-man cases shows that leadless endocardial pacing may be safely applied and effective, conferring short- to-mid-term symptomatic benefits. These promising findings are yet to be substantiated by larger ongoing studies. CLINICAL TRIAL REGISTRATION INFORMATION: http://clinicaltrials.gov/ct2/show/NCT01294527.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Alternative leadless solutions such as energy harvesters and ultrasound-based wireless pacers are hindered by a large device size that leads to mechanically stressed fixation mechanisms.
“Alternative solutions for leadless devices have been proposed, including utilization of energy harvesters11, 12 and ultrasound-based wireless pacers8, 13, 14. However, these are similarly hindered by a large device size that leads to mechanically stressed fixation mechanisms.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [13]
Cited by
Sorted by citations
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183 · see citing works
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159 · see citing works
Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system
Abiri, P., Abiri, A., Packard, R. R. S., Ding, Y., Yousefi, A., Ma, J., Bersohn, M., Nguyen, K.-L., Markovic, D., Moloudi, S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06493-5 · Cited by 67 · see citing works
- Authors
- Auricchio, A., Delnoy, P.-P., Regoli, F., Seifert, M., Markou, T., Butter, C., & for the collaborative study group
- Affiliations
- Istituto Cardiocentro Ticino (CH)
- Isala (NL)
- Immanuel Klinikum Bernau (DE)
- Corresponding author
- Auricchio, A.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-05-23
- Volume
- 15
- Issue
- 8
- Pages
- 1191-1197
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2152403933
- Cited by
- 94
- References
- 0
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 3 · 2022: 7 · 2021: 8 · 2020: 10 · 2019: 3 · 2018: 10 · 2017: 6 · 2016: 10 · 2015: 14 · 2014: 14 · 2013: 2
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- EP Europace (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Surgery › Cardiac Structural Anomalies and Repair
- Keywords
- left ventricular endocardial pacing, cardiac resynchronization therapy, heart failure, pacing threshold, implantable cardioverter-defibrillator
- MeSH terms
- Aged, Cardiac Pacing, Artificial, Electrodes, Implanted, Equipment Design, Heart Failure, Humans, Male, Pacemaker, Artificial, Pilot Projects, Ultrasonic Therapy, Treatment Outcome, Ventricular Dysfunction, Left, Equipment Failure Analysis, Prostheses and Implants, Micro-Electrical-Mechanical Systems, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.