Rivaroxaban and dabigatran in patients undergoing catheter ablation of atrial fibrillation
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
AIMS: The recent availability of the novel oral anticoagulants (NOACs) may have led to a change in the anticoagulation regimens of patients referred to catheter ablation of atrial fibrillation (AF). Preliminary data exist concerning dabigatran, but information regarding the safety and efficacy of rivaroxaban in this setting is currently scarce. METHODS AND RESULTS: Of the 556 consecutive eligible patients (age 61.0 ± 9.6; 74.6% men; 61.2% paroxysmal AF) undergoing AF catheter ablation in our centre (October 2012 to September 2013) and enroled in a systematic standardized 30-day follow-up period: 192 patients were under vitamin K antagonists (VKAs), 188 under rivaroxaban, and 176 under dabigatran. Peri-procedural mortality and significant systemic or pulmonary thromboembolism (efficacy outcome), as well as bleeding events (safety outcome) during the 30 days following the ablation were evaluated according to anticoagulation regimen. During a 12-month time interval, the use of the NOACs in this population rose from <10 to 70%. Overall, the rate of events was low with no significant differences regarding: thrombo-embolic events in 1.3% (VKA 2.1%; rivaroxaban 1.1%; dabigatran 0.6%; P = 0.410); major bleeding in 2.3% (VKA 4.2%; rivaroxaban 1.6%; dabigatran 1.1%; P = 0.112), and minor bleeding 1.4% (VKA 2.1%; rivaroxaban 1.6%; dabigatran 0.6%; P = 0.464). No fatal events were observed. CONCLUSION: The use of the NOAC in patients undergoing catheter ablation of AF has rapidly evolved (seven-fold) over 1 year. These preliminary data suggest that rivaroxaban and dabigatran in the setting of catheter ablation of AF are efficient and safe, compared with the traditional VKA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Incidence and prevalence of atrial fibrillation: an analysis based on 8.3 million patients
Wilke, T., Groth, A., Mueller, S., Pfannkuche, M., Verheyen, F., Linder, R., Maywald, U., Bauersachs, R., & Breithardt, G. (2013) · Europace · doi:10.1093/europace/eus333 · Cited by 397
Hohnloser, S. H., & Camm, A. J. (2013) · EP Europace · doi:10.1093/europace/eut241 · Cited by 93
Cited by
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · Europace · doi:10.1093/europace/euw295 · Cited by 6,439
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Metadata
- Authors
- Providencia, R., Marijon, E., Albenque, J.-P., Combes, S., Combes, N., Jourda, F., Hireche, H., Morais, J., & Boveda, S.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-02-18
- Volume
- 16
- Issue
- 8
- Pages
- 1137-1144
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2119827548
- Cited by
- 80
- References
- 3
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.