AIMS: Idiopathic ventricular fibrillation (iVF) accounts for up to 14% of VF incidence. Data regarding long-term outcome and clinical risk markers of arrhythmia recurrence are scarce. The objective of our study was to describe a long-term follow-up (FU) of a cohort of iVF survivors in our centre during the past 20 years, and to investigate the influence of clinical parameters, e.g. presence of an early repolarization pattern (ERP), on recurrence rate of arrhythmias. METHODS AND RESULTS: Thirty-five iVF survivors were identified and retrospectively analysed regarding recurrent implantable cardioverter-defibrillator (ICD) interventions and covariates potentially influencing arrhythmia recurrence. Appropriate ICD interventions occurred in 15 patients (43%) after a median of 6.6 years during a median FU period of 8.8 years. Two patients (13%) received the first appropriate therapy after an assumed average ICD battery longevity of 7 years, while in all other patients, the first therapy occurred within the first ICD period. Appropriate interventions were observed more often and earlier in patients with ERP (HR 3.9; 1.4-11.0; P = 0.01), whereas all other covariates failed to predict subsequent events. A high incidence of inappropriate ICD therapies (67 interventions in 14 patients) could be attributed to the occurrence of atrial fibrillation (66% of all inappropriate therapies). CONCLUSION: The recurrence rate of ventricular arrhythmias in iVF survivors is high and recurrence might occur delayed (>7 years after the initial event). ERP seems to be highly predictive with respect to early arrhythmia recurrence. Our results highlight that better pathophysiologic understanding of ERP might facilitate a better risk stratification before and an optimal treatment after an iVF event. The high rate of AF and ERP in iVF survivors might indicate an underlying heart disease or myocardial electrical disorder not apparent at the index event.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euv301

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 55

Metadata

Authors
Siebermair, J., Sinner, M. F., Beckmann, B.-M., Laubender, R. P., Martens, E., Sattler, S., Fichtner, S., Estner, H. L., Kääb, S., & Wakili, R.
Venue
Europace
Published
2016-01-11
Volume
18
Issue
5
Pages
718-725
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2232711434
Cited by
55
References
4
FWCI
5.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early repolarization pattern is the strongest predictor of arrhythmia recurrence in patients with idiopathic ventricular fibrillation: results from a single centre long-term follow-up over 20 years. https://app.cochat.ai/papers/10.1093/europace/euv301
The paper
Siebermair, J., Sinner, M. F., Beckmann, B.-M., Laubender, R. P., Martens, E., Sattler, S., Fichtner, S., Estner, H. L., Kääb, S., & Wakili, R. (2016). Early repolarization pattern is the strongest predictor of arrhythmia recurrence in patients with idiopathic ventricular fibrillation: results from a single centre long-term follow-up over 20 years. Europace. https://doi.org/10.1093/europace/euv301

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.