The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting
Open accessAbstract
To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA2DS2-VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting. It must exclude patients with implanted devices and known AF, and requires targeted additional 12-lead ECGs to optimize specificity. Under these circumstances, the expenses per diagnosed new AF patient and preventable stroke are reasonable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Hart, R. G., Pearce, L. A., & Aguilar, M. I. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-12-200706190-00007 · Cited by 4,793 · cited 1×
“2 Given that about two out of three strokes (64%) can be prevented using proper oral anticoagulation therapy, this allowed us to give an estimate of the screening costs needed to prevent one stroke every year (excluding the cost of the anticoagulation therapy itself).(16) All costs were expressed in Euro (E).”
BackgroundMass Screening for Untreated Atrial Fibrillation: The STROKESTOP Study
Svennberg, E., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman, V., & Rosenqvist, M. (2015) · Circulation · doi:10.1161/circulationaha.114.014343 · Cited by 605
Lowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
Wireless smartphone ECG enables large-scale screening in diverse populations
HABERMAN, Z. C., JAHN, R. T., BOSE, R., TUN, H., SHINBANE, J. S., DOSHI, R. N., CHANG, P. M., & SAXON, L. A. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12634 · Cited by 212
Aronsson, M., Svennberg, E., Rosenqvist, M., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman-Kull, V., & Levin, L.-Å. (2015) · Europace · doi:10.1093/europace/euv083 · Cited by 154
Validation and clinical use of a novel diagnostic device for screening of atrial fibrillation
Tieleman, R. G., Plantinga, Y., Rinkes, D., Bartels, G. L., Posma, J. L., Cator, R., Hofman, C., & Houben, R. P. (2014) · Europace · doi:10.1093/europace/euu057 · Cited by 138 · cited 12×
“The algorithm of the MyDiagnostick will indicate AF based on an irregular R–R interval which is present during at least 75% of the 1-min recording.(11) The AliveCor is coupled with an iPhone and allows a noise-filtered lead I ECG recording by means of the corresponding AliveECG app.”
MethodResultInfluentialShort-term ECG for out of hospital detection of silent atrial fibrillation episodes
Doliwa, P. S., Frykman, V., & Rosenqvist, M. (2009) · Scandinavian Cardiovascular Journal · doi:10.1080/14017430802593435 · Cited by 105
The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care
Vaes, B., Stalpaert, S., Tavernier, K., Thaels, B., Lapeire, D., Mullens, W., & Degryse, J. (2014) · BMC Family Practice · doi:10.1186/1471-2296-15-113 · Cited by 81
Research works printed but not linked: 11
- 10.1093/europace/euq350 · DOI · Paper page
- 10.1093/europace/eus305 · DOI · Paper page
- Cooke, 2006, Is pulse palpation helpful in detecting atrial fibrillation? A systematic review, J Fam Pract, 55, 130
- Morgan, 2002, Randomised trial of two approaches to screening for atrial fibrillation in UK general practice, Br J Gen Pract, 52, 373
- 10.1016/j.hrthm.2014.11.015 · DOI
- 10.1093/europace/euu213 · DOI · Paper page
- 10.1136/heartjnl-2014-307059 · DOI
- Viera, 2005, Understanding interobserver agreement: the kappa statistic, Fam Med, 37, 360
- Lau, 2012, Validation of an iPhone ECG application suitable for community screening for silent atrial fibrillation: a novel way to prevent stroke, Circulation, 126, A16810
- 10.1136/bmj.39227.551713.AE · DOI · Paper page
- 10.1186/1471-2261-13-41 · DOI
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Self-citationVan Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
Chan, P., Wong, C., Poh, Y. C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Poh, M., Chu, D. W., & Siu, C. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003428 · Cited by 240
Metadata
- Authors
- Desteghe, L., Raymaekers, Z., Lutin, M., Vijgen, J., Dilling-Boer, D., Koopman, P., Schurmans, J., Vanduynhoven, P., Dendale, P., & Heidbuchel, H.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-02-17
- Volume
- 19
- Issue
- 1
- Pages
- euw025
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2285302608
- Cited by
- 164
- References
- 10
- FWCI
- 15.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- Funders
- foundation Limburg Sterk Merk
- province of Limburg
- Flemish government
- Hasselt University
- Ziekenhuis Oost-Limburg,
- Jessa Hospital
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting. https://app.cochat.ai/papers/10.1093/europace/euw025
- The paper
- Desteghe, L., Raymaekers, Z., Lutin, M., Vijgen, J., Dilling-Boer, D., Koopman, P., Schurmans, J., Vanduynhoven, P., Dendale, P., & Heidbuchel, H. (2016). Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting. Europace. https://doi.org/10.1093/europace/euw025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.