Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting

Open access
Desteghe, Lien, Raymaekers, Zina, Lutin, Mark, Vijgen, Johan, Dilling-Boer, Dagmara, Koopman, Pieter, Schurmans, Joris, Vanduynhoven, Philippe, Dendale, Paul, Heidbuchel, Hein · 2016 · Europace

Abstract

To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA2DS2-VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting. It must exclude patients with implanted devices and known AF, and requires targeted additional 12-lead ECGs to optimize specificity. Under these circumstances, the expenses per diagnosed new AF patient and preventable stroke are reasonable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/euw025

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Research works printed but not linked: 11

  1. 10.1093/europace/euq350 · DOI · Paper page
  2. 10.1093/europace/eus305 · DOI · Paper page
  3. Cooke, 2006, Is pulse palpation helpful in detecting atrial fibrillation? A systematic review, J Fam Pract, 55, 130
  4. Morgan, 2002, Randomised trial of two approaches to screening for atrial fibrillation in UK general practice, Br J Gen Pract, 52, 373
  5. 10.1016/j.hrthm.2014.11.015 · DOI
  6. 10.1093/europace/euu213 · DOI · Paper page
  7. 10.1136/heartjnl-2014-307059 · DOI
  8. Viera, 2005, Understanding interobserver agreement: the kappa statistic, Fam Med, 37, 360
  9. Lau, 2012, Validation of an iPhone ECG application suitable for community screening for silent atrial fibrillation: a novel way to prevent stroke, Circulation, 126, A16810
  10. 10.1136/bmj.39227.551713.AE · DOI · Paper page
  11. 10.1186/1471-2261-13-41 · DOI

Cited by

See all 164

Metadata

Authors
Desteghe, L., Raymaekers, Z., Lutin, M., Vijgen, J., Dilling-Boer, D., Koopman, P., Schurmans, J., Vanduynhoven, P., Dendale, P., & Heidbuchel, H.
Venue
Europace
Published
2016-02-17
Volume
19
Issue
1
Pages
euw025
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2285302608
Cited by
164
References
10
FWCI
15.94
Type
journal article
Language
en
Open access
bronze
Funders
  • foundation Limburg Sterk Merk
  • province of Limburg
  • Flemish government
  • Hasselt University
  • Ziekenhuis Oost-Limburg,
  • Jessa Hospital

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting. https://app.cochat.ai/papers/10.1093/europace/euw025
The paper
Desteghe, L., Raymaekers, Z., Lutin, M., Vijgen, J., Dilling-Boer, D., Koopman, P., Schurmans, J., Vanduynhoven, P., Dendale, P., & Heidbuchel, H. (2016). Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting. Europace. https://doi.org/10.1093/europace/euw025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.