Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.

The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care

Open access
Vaes, Bert, Stalpaert, Silke, Tavernier, Karen, Thaels, Britt, Lapeire, Daphne, Mullens, Wilfried, Degryse, Jan · 2014 · BMC Family Practice

Abstract

BACKGROUND: Atrial fibrillation is very common in people aged 65 or older. This condition increases the risk of death, congestive heart failure and thromboembolic conditions. Many patients with atrial fibrillation are asymptomatic and a cerebrovascular accident (CVA) is often the first clinical presentation. Guidelines concerning the prevention of CVA recommend monitoring the heart rate in patients aged 65 or older. Recently, the MyDiagnostick (Applied Biomedical Systems BV, Maastricht, The Netherlands) was introduced as a new screening tool which might serve as an alternative for the less accurate pulse palpation. This study was designed to explore the diagnostic accuracy of the MyDiagnostick for the detection of atrial fibrillation. METHODS: A phase II diagnostic accuracy study in a convenience sample of 191 subjects recruited in primary care. The majority of participants were patients with a known history of atrial fibrillation (n=161). Readings of the MyDiagnostick were compared with electrocardiographic recordings. Sensitivity and specificity and their 95% confidence interval were calculated using 2x2 tables. RESULTS: A prevalence of 54% for an atrial fibrillation rhythm was found in the study population at the moment of the study. A combination of three measurements with the MyDiagnostick for each patient showed a sensitivity of 94% (95% CI 87 - 98) and a specificity of 93% (95% CI 85 - 97). CONCLUSION: The MyDiagnostick is an easy-to-use device that showed a good diagnostic accuracy with a high sensitivity and specificity for atrial fibrillation in a convenience sample in primary care. Future research is needed to determine the place of the MyDiagnostick in possible screening or case-finding strategies for atrial fibrillation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2296-15-113

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The MyDiagnostick device.
Figure 1 The MyDiagnostick device.CC BY · PubMed Central
Figure 2 Single-lead ECGs provided by the MyDiagnostick (sinus rhythm and atrial fibrillation).
Figure 2 Single-lead ECGs provided by the MyDiagnostick (sinus rhythm and atrial fibrillation).CC BY · PubMed Central
Figure 3 Flow chart of study participants.
Figure 3 Flow chart of study participants.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 81

Metadata

Authors
Vaes, B., Stalpaert, S., Tavernier, K., Thaels, B., Lapeire, D., Mullens, W., & Degryse, J.
Affiliations
  • UCLouvain (BE)
  • KU Leuven (BE)
Corresponding author
Vaes, Bert
Venue
BMC Family Practice
Published
2014-06-09
Volume
15
Issue
1
Pages
113-113
ISSN
1471-2296 (ISSN-L)
OpenAlex
W2107017489
Cited by
81
References
24
Citations by year
2026: 2 · 2025: 3 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 12 · 2020: 11 · 2019: 6 · 2018: 7 · 2017: 9 · 2016: 5 · 2015: 3
FWCI
3.89
Type
journal article
Language
en
Open access
Locations
  • BMC Family Practice (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Lirias (submittedVersion, cc-by)
  • DIAL (Catholic University of Leuven) (submittedVersion, other-oa)
  • Document Server@UHasselt (UHasselt) (submittedVersion, cc-by)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Health Promotion and Cardiovascular Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
atrial fibrillation, pulse rate monitoring, diagnostic accuracy, screening, primary care, electrocardiogram, stroke prevention, older adults, case finding
MeSH terms
Aged, Aged, 80 and over, Atrial Fibrillation, Diagnosis, Differential, Electrocardiography, Female, Humans, Male, Middle Aged, Primary Health Care, Sensitivity and Specificity, Prevalence, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care. https://app.cochat.ai/papers/10.1186/1471-2296-15-113
The paper
Vaes, B., Stalpaert, S., Tavernier, K., Thaels, B., Lapeire, D., Mullens, W., & Degryse, J. (2014). The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care. BMC Family Practice. https://doi.org/10.1186/1471-2296-15-113

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.