Wrist band photoplethysmography in detection of individual pulses in atrial fibrillation and algorithm-based detection of atrial fibrillation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Aims: Atrial fibrillation (AF) is the most common tachyarrhythmia and a significant cause of cardioembolic strokes. Atrial fibrillation is often intermittent and asymptomatic making detection a major clinical challenge. We evaluated a photoplethysmography (PPG) wrist band in individual pulse detection in patients with AF and tested the reliability of two commonly used algorithms for AF detection. Methods and results: A 5-min PPG was recorded from patients with AF or sinus rhythm (SR) with a wrist band and analysed with two AF detection algorithms; AFEvidence and COSEn. Simultaneously registered electrocardiogram served as the golden standard for rhythm analysis and was interpreted by two cardiologists. The study population consisted of 213 (106 AF, 107 SR) patients. The wrist band PPG achieved individual pulse detection with a sensitivity of 91.7 ± 11.2% and a positive predictive value (PPV) of 97.5 ± 4.6% for AF, with a sensitivity of 99.4 ± 1.5% [7.7% (95% confidence interval, 95% CI 5.5% to 9.9%); P < 0.001] and PPV of 98.1 ± 4.1% [0.6% (95% CI −0.6% to 1.7%); P = 0.350] for SR. The pulse detection sensitivity was lower 86.7 ± 13.9% with recent-onset AF (AF duration <48 h, n = 43, 40.6%) as compared to late AF (≥48 h, n = 63, 59.4%) with 95.1 ± 7.2% [−8.3% (95% CI −12.9% to −3.7%); P = 0.001]. For the detection of AF from the wrist band PPG, the sensitivities were 96.2%/95.3% and specificity 98.1% with two algorithms. Conclusion: The wrist band PPG enabled accurate algorithm-based detection of AF with two AF detection algorithms and high individual pulse detection. Algorithms allowed accurate detection of AF from the PPG. A PPG wrist band provides an easy solution for AF screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hart, R. G., Pearce, L. A., & Aguilar, M. I. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-12-200706190-00007 · Cited by 4,793
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Fitzmaurice, D. A., Hobbs, F. D. R., Jowett, S., Mant, J., Murray, E. T., Holder, R., Raftery, J. P., Bryan, S., Davies, M., Lip, G. Y. H., et al. (2007) · BMJ · doi:10.1136/bmj.39280.660567.55 · Cited by 405
Xiong, Q., Proietti, M., Senoo, K., & Lip, G. Y. H. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.05.011 · Cited by 161
Cited by
Nielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Role of wearable rhythm recordings in clinical decision making—The wEHRAbles project
Manninger, M., Kosiuk, J., Zweiker, D., Njeim, M., Antolic, B., Kircanski, B., Larsen, J. M., Svennberg, E., Vanduynhoven, P., & Duncker, D. (2020) · Clinical Cardiology · doi:10.1002/clc.23404 · Cited by 50
Eerikäinen, L. M., Bonomi, A. G., Dekker, L. R. C., Vullings, R., & Aarts, R. M. (2020) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2020.03.001 · Cited by 24
“Many studies did not report assessment and exclusion of outliers or badquality data.(21,25,26,34,36,39,40) Nemati et al(20) and Shashikumar et al(28) did not exclude data; instead they selected the best channel from 8 measured PPG channels for analysis based on signal quality metrics, which were derived from the raw P…”
Method
Metadata
- Authors
- Väliaho, E. S., Kuoppa, P., Lipponen, J. A., Martikainen, T. J., Jäntti, H., Rissanen, T. T., Kolk, I., Castrén, M., Halonen, J., Tarvainen, M. P., & Hartikainen, J. E. K.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-04-27
- Volume
- 21
- Issue
- 7
- Pages
- 1031-1038
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2943446474
- Cited by
- 39
- References
- 6
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wrist band photoplethysmography in detection of individual pulses in atrial fibrillation and algorithm-based detection of atrial fibrillation. https://app.cochat.ai/papers/10.1093/europace/euz060
- The paper
- Väliaho, E. S., Kuoppa, P., Lipponen, J. A., Martikainen, T. J., Jäntti, H., Rissanen, T. T., Kolk, I., Castrén, M., Halonen, J., Tarvainen, M. P., & Hartikainen, J. E. K. (2019). Wrist band photoplethysmography in detection of individual pulses in atrial fibrillation and algorithm-based detection of atrial fibrillation. EP Europace. https://doi.org/10.1093/europace/euz060
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.