Design-Related Bias in Hospital Fall Risk Screening Tool Predictive Accuracy Evaluations: Systematic Review and Meta-Analysis
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Fall risk screening tools are frequently used as a part of falls prevention programs in hospitals. Design-related bias in evaluations of tool predictive accuracy could lead to overoptimistic results, which would then contribute to program failure in practice. METHODS: A systematic review was undertaken. Two blind reviewers assessed the methodology of relevant publications into a four-point classification system adapted from multiple sources. The association between study design classification and reported results was examined using linear regression with clustering based on screening tool and robust variance estimates with point estimates of Youden Index (= sensitivity + specificity - 1) as the dependent variable. Meta-analysis was then performed pooling data from prospective studies. RESULTS: Thirty-five publications met inclusion criteria, containing 51 evaluations of fall risk screening tools. Twenty evaluations were classified as retrospective validation evaluations, 11 as prospective (temporal) validation evaluations, and 20 as prospective (external) validation evaluations. Retrospective evaluations had significantly higher Youden Indices (point estimate [95% confidence interval]: 0.22 [0.11, 0.33]). Pooled Youden Indices from prospective evaluations demonstrated the STRATIFY, Morse Falls Scale, and nursing staff clinical judgment to have comparable accuracy. DISCUSSION: Practitioners should exercise caution in comparing validity of fall risk assessment tools where the evaluation has been limited to retrospective classifications of methodology. Heterogeneity between studies indicates that the Morse Falls Scale and STRATIFY may still be useful in particular settings, but that widespread adoption of either is unlikely to generate benefits significantly greater than that of nursing staff clinical judgment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Internal validation of predictive models
Steyerberg, E. W., Harrell, F. E., Borsboom, G. J. J. M., Eijkemans, M. J. C., Vergouwe, Y., & Habbema, J. D. F. (2001) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(01)00341-9 · Cited by 2,746
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 4×
“Study Design Classifications In their sentinel work, Lijmer and colleagues (23) identified eight design characteristics that they included in their analysis.”
BackgroundMethodResultInfluentialRisk factors and risk assessment tools for falls in hospital in-patients: a systematic review
Oliver, D. (2004) · Age and Ageing · doi:10.1093/ageing/afh017 · Cited by 714 · cited 3×
“Calculation of these statistics and confidence intervals of these for published tools have been described in a previous review (19).”
Background
Cited by
Preventing Falls and Fall-Related Injuries in Hospitals
Oliver, D., Healey, F., & Haines, T. P. (2010) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2010.06.005 · Cited by 480
Self-citationA systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Metadata
- Authors
- Haines, T. P., Hill, K., Walsh, W., & Osborne, R.
- Venue
- The Journals of Gerontology Series A: Biological Sciences and Medical Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-06-01
- Volume
- 62
- Issue
- 6
- Pages
- 664-672
- ISSN
- 1079-5006 (ISSN-L)
- 1758-535X
- OpenAlex
- W2167635185
- Cited by
- 172
- References
- 6
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design-Related Bias in Hospital Fall Risk Screening Tool Predictive Accuracy Evaluations: Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1093/gerona/62.6.664
- The paper
- Haines, T. P., Hill, K., Walsh, W., & Osborne, R. (2007). Design-Related Bias in Hospital Fall Risk Screening Tool Predictive Accuracy Evaluations: Systematic Review and Meta-Analysis. The Journals of Gerontology Series A: Biological Sciences and Medical Sciences. https://doi.org/10.1093/gerona/62.6.664
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.