A multicentre efficacy and safety study of the single contraceptive implant Implanon
The DOI matches its Crossref record.
Abstract
An open, multicentre study was performed to assess efficacy, safety and acceptability of the single-rod contraceptive implant Implanon. The study involved 635 young healthy women, who were sexually active and of childbearing potential. The women were followed up every 3 months over the entire study period. Originally the study was designed for 2 years, but was extended to 3 years in a group of 147 women from two centres. Altogether, 21 centres in nine different countries participated. The average age of the women was 29 years (range 18-42 years), of whom 83.5% had been pregnant in the past. No pregnancy occurred during treatment with Implanon, resulting in a Pearl Index of 0 (95% confidence interval: 0.0-0.2). In the first 2 years, 31% had discontinued the treatment. Of the 147 women in the study extension, nine discontinued (6%) treatment. Bleeding irregularities was the main reason for discontinuation during the first 2 years of use (17.2%) and adverse experiences in the third year (3.4%). Implant insertion and removal were fast and uncomplicated in the vast majority (97%) of cases. Return of fertility was prompt. In conclusion, Implanon has excellent contraceptive action during its lifetime of 3 years. The safety profile is acceptable and not essentially different from progestogens in general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Darney, P., Patel, A., Rosen, K., Shapiro, L. S., & Kaunitz, A. M. (2009) · Fertility and Sterility · doi:10.1016/j.fertnstert.2008.02.140 · Cited by 247
Efficacy of contraceptive methods: A review of the literature
Mansour, D., Inki, P., & Gemzell-Danielsson, K. (2010) · The European Journal of Contraception & Reproductive Health Care · doi:10.3109/13625180903427675 · Cited by 174
Fauser, B. C. J. M., Mannaerts, B. M. J. L., Devroey, P., Leader, A., Boime, I., & Baird, D. T. (2009) · Human Reproduction Update · doi:10.1093/humupd/dmn065 · Cited by 161
“(Croxatto et al., 1999).”
BackgroundBeerthuizen, R., van Beek, A., Massai, R., Mäkäräinen, L., Hout, J. I., & Bennink, H. C. (2000) · Human Reproduction · doi:10.1093/humrep/15.1.118 · Cited by 127
Bahamondes, L., Monteiro-Dantas, C., Espejo-Arce, X., dos Santos Fernandes, A. M., Lui-Filho, J. F., Perrotti, M., & Petta, C. A. (2006) · Human Reproduction · doi:10.1093/humrep/dei358 · Cited by 66
“Levels are, however, higher than those observed in users of DMPA (Makarainen et al., 1998), and amenorrhoea occurs in only ~20% of users (Croxatto et al., 1999).”
Background
Metadata
- Authors
- Croxatto, H. B.
- Venue
- Human Reproduction
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-04-01
- Volume
- 14
- Issue
- 4
- Pages
- 976-981
- ISSN
- 0268-1161 (ISSN-L)
- 1460-2350
- OpenAlex
- W2062847003
- Cited by
- 170
- References
- 0
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multicentre efficacy and safety study of the single contraceptive implant Implanon. https://app.cochat.ai/papers/10.1093/humrep/14.4.976
- The paper
- Croxatto, H. B. (1999). A multicentre efficacy and safety study of the single contraceptive implant Implanon. Human Reproduction. https://doi.org/10.1093/humrep/14.4.976
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.