CoChat

Accurate prediction of pregnancy viability by means of a simple scoring system

Bottomley, Cecilia, Van Belle, Vanya, Kirk, Emma, Van Huffel, Sabine, Timmerman, Dirk, Bourne, Tom · 2013 · Human Reproduction
Cited by 57

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

STUDY QUESTION: What is the performance of a simple scoring system to predict whether women will have an ongoing viable intrauterine pregnancy beyond the first trimester? SUMMARY ANSWER: A simple scoring system using demographic and initial ultrasound variables accurately predicts pregnancy viability beyond the first trimester with an area under the curve (AUC) in a receiver operating characteristic curve of 0.924 [95% confidence interval (CI) 0.900-0.947] on an independent test set. WHAT IS KNOWN ALREADY: Individual demographic and ultrasound factors, such as maternal age, vaginal bleeding and gestational sac size, are strong predictors of miscarriage. Previous mathematical models have combined individual risk factors with reasonable performance. A simple scoring system derived from a mathematical model that can be easily implemented in clinical practice has not previously been described for the prediction of ongoing viability. STUDY DESIGN, SIZE AND DURATION: This was a prospective observational study in a single early pregnancy assessment centre during a 9-month period. PARTICIPANTS/MATERIALS, SETTING AND METHODS: A cohort of 1881 consecutive women undergoing transvaginal ultrasound scan at a gestational age <84 days were included. Women were excluded if the first trimester outcome was not known. Demographic features, symptoms and ultrasound variables were tested for their influence on ongoing viability. Logistic regression was used to determine the influence on first trimester viability from demographics and symptoms alone, ultrasound findings alone and then from all the variables combined. Each model was developed on a training data set, and a simple scoring system was derived from this. This scoring system was tested on an independent test data set. MAIN RESULTS AND THE ROLE OF CHANCE: The final outcome based on a total of 1435 participants was an ongoing viable pregnancy in 885 (61.7%) and early pregnancy loss in 550 (38.3%) women. The scoring system using significant demographic variables alone (maternal age and amount of bleeding) to predict ongoing viability gave an AUC of 0.724 (95% CI = 0.692-0.756) in the training set and 0.729 (95% CI = 0.684-0.774) in the test set. The scoring system using significant ultrasound variables alone (mean gestation sac diameter, mean yolk sac diameter and the presence of fetal heart beat) gave an AUC of 0.873 (95% CI = 0.850-0.897) and 0.900 (95% CI = 0.871-0.928) in the training and the test sets, respectively. The final scoring system using demographic and ultrasound variables together gave an AUC of 0.901 (95% CI = 0.881-0.920) and 0.924 (CI = 0.900-0.947) in the training and the test sets, respectively. After defining the cut-off at which the sensitivity is 0.90 on the training set, this model performed with a sensitivity of 0.92, specificity of 0.73, positive predictive value of 84.7% and negative predictive value of 85.4% in the test set. LIMITATIONS, REASONS FOR CAUTION: BMI and smoking variables were a potential omission in the data collection and might further improve the model performance if included. A further limitation is the absence of information on either bleeding or pain in 18% of women. Caution should be exercised before implementation of this scoring system prior to further external validation studies WIDER IMPLICATIONS OF THE FINDINGS: This simple scoring system incorporates readily available data that are routinely collected in clinical practice and does not rely on complex data entry. As such it could, unlike most mathematical models, be easily incorporated into normal early pregnancy care, where women may appreciate an individualized calculation of the likelihood of ongoing pregnancy viability. STUDY FUNDING/COMPETING INTEREST(S): Research by V.V.B. supported by Research Council KUL: GOA MaNet, PFV/10/002 (OPTEC), several PhD/postdoc & fellow grants; IWT: TBM070706-IOTA3, PhD Grants; IBBT; Belgian Federal Science Policy Office: IUAP P7/(DYSCO, `Dynamical systems, control and optimization', 2012-2017). T.B. is supported by the Imperial Healthcare NHS Trust NIHR Biomedical Research Centre. TRIAL REGISTRATION NUMBER: Not applicable.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/humrep/des352

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 57

Metadata

Authors
Bottomley, C., Van Belle, V., Kirk, E., Van Huffel, S., Timmerman, D., & Bourne, T.
Venue
Human Reproduction
Published
2012-10-30
Volume
28
Issue
1
Pages
68-76
ISSN
  • 0268-1161 (ISSN-L)
  • 1460-2350
OpenAlex
W2018363437
Cited by
57
References
10
FWCI
3.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accurate prediction of pregnancy viability by means of a simple scoring system. https://app.cochat.ai/papers/10.1093/humrep/des352
The paper
Bottomley, C., Van Belle, V., Kirk, E., Van Huffel, S., Timmerman, D., & Bourne, T. (2013). Accurate prediction of pregnancy viability by means of a simple scoring system. Human Reproduction. https://doi.org/10.1093/humrep/des352

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.